This document contains safety notices in accordance with appropriate standards. In the interests of conformity
with the territory standards for the country concerned, the equivalent territorial admonishments are also shown.
Any installation, adjustment, maintenance and repair of the equipment must only be carried out by trained,
authorized personnel. At all times, personnel must comply with any safety notices and instructions.
Specific hazards are indicated by symbol labels on or near the affected parts of the equipment. The labels
conform to international standards, are triangular in shape, and are colored black on a yellow background. An
informative text label may accompany the symbol label.
Hazard labeling is supplemented by safety notices in the appropriate equipment manual. These notices contain
additional information on the nature of the hazard and may also specify precautions.
Note: The grantee is not responsible for any changes or modifications not expressly approved by the party
responsible for compliance. Such modifications could void the user‟s authority to operate the equipment.
For compliance with the occupational/controlled exposure RF exposure limits, each individual antenna used for
this transmitter must be installed to provide a separation distance greater than 20cm or more from all persons
during normal operation and must not be co-located with any other antenna for meeting RF exposure
requirements.
Warning Notices:
These draw the attention of personnel to hazards that may cause death or injury to the operator or others.
Examples of use are cases of high voltage, laser emission, toxic substances, point of high temperature, etc.
The design of the antenna installation needs to be implemented in such a way so as to ensure RF radiation
safety levels and non-environmental pollution during operation.
Note: Antennas, feeders and couplers are not included in the packing list; solution provider should consider
these accessories according to site conditions.
WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and
QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to
operate this device. You MUST register Part 90 Class B and Part 20 signal boosters (as defined in 47
CFR 90.219) online at www.fcc.gov/signal-boosters/registration. Unauthorized use may result in
significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation.
Note: The grantee is not responsible for any changes or modifications not expressly approved by the party
responsible for compliance. Such modifications could void the user‟s authority to operate the equipment.
Alert:
These draw the attention of personnel to hazards that may cause damage to the equipment. An example of use
is the case of static electricity hazard.
Caution notices may also be used in the handbook to draw attention to matters that do not constitute a risk of
causing damage to the equipment but where there is a possibility of seriously impairing its performance, e.g. by
mishandling or gross maladjustment. Warnings and Cautions within the main text do not incorporate labels and
may be in shortened form.
Disconnection of the RU RF connectors may cause damage to the equipment when power is on.
The application antenna and RF cable are not provided. The antenna gain should not exceed 9dBi for uplink
INSTALLATION GUIDE FOR RH-7W22
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 11
and should not exceed 4dBi for downlink
WARNING!
Use only authorized and approved antennas, cables and/or coupling devices! The use of unapproved antennas,
cables or coupling devices could cause damage and may be of violation of FCC regulations. The use of
unapproved antennas, cables and/or coupling devices is illegal under FCC regulations and may subject the
user to fines.
End of Section
INSTALLATION GUIDE FOR RH-7W22
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 12
1 GENERAL INFORMATION
The Public Safety Distributed Antenna System RH-7W22 (hereinafter called “PS DAS”) consists of Master Unit
(MU) and Remote Unit (RU). The MU includes the MU Chassis, Power Supply Unit (PSU), Fiber Optical
module and RF module. Optical module with a modular design, it can support up to 8 independent Remote
Units. The Remote Unit is designed with a compact form for easy installation; it is an integrated design which
supports 2 independent bands, 700MHz and 800MHz.
The low signal transmission loss of optical fiber is applicable for long distance transmission. PS DAS can
support the optical transmission of up to 6.5dBo optical loss, equivalent to 8 miles fiber length.
Main Features
Dual-band configuration supports 700MHz and 800MHz public safety bands
Supports P25 P1/P2 digital and conventional analog communications simultaneously
Supports FirstNetTM LTE Band 14 (Class B)
Up to 32 channels (Class A) / 3 sub bands (Class B)
Channelized Auto Level Control (ALC) supported (Class A)
Channelized uplink squelch supported (Class A)
Web based GUI for intelligent configuration, SNMP supported
Built-in mandatory isolation test to prevent oscillation
NFPA 1221 compliant dry contact alarms on MU / RUs
NFPA 1221 compliant NEMA 4X enclosure for MU / RUs
Alarming output to supervised circuits for: antenna failure, signal booster failure, and etc.
The following figure shows the enclosure of the PS DAS Master unit and Remote unit.
Figure 1: Master Unit (MU)
INSTALLATION GUIDE FOR RH-7W22
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 13
Figure 2: Remote Unit (RU)
End of Section
INSTALLATION GUIDE FOR RH-7W22
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 14
… …
Remote Unit
Remote Unit
Master Unit
Up to 8
2 EQUIPMENT DESCRIPTION
2.1 SYSTEM DIAGRAM
Figure 3: PS DAS Functional Block Diagram
In the downlink path, the BTS signals are received by the donor antenna of the Master Unit. After the duplexer,
the signals are sent to the LNA module for pre-amplification and to the digital RF integrated module for digital
filtering and frequency conversion. Then the DL signals will be sent to the Remote Unit to amplify power by
optical fiber, and filter via the duplexer. After amplification, the signals are transmitted at the MT port to the
service antenna.
In the uplink path, the mobile signals are received by the service antenna. After the MT port duplexer, the
signals are sent to the LNA, integrated module for digital filtering, then the UL signals will be sent to the Master
Unit for power amplification and to the duplexer. After that, the uplink signals are sent to the donor antenna for
transmission back to the BTS.
The devices can detect output power, refer to expect output power which is set by user, the device can reduce
or increase internal ATT automatically and remain the expected output power. This is the AGC principle.
INSTALLATION GUIDE FOR RH-7W22
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 15
MU Bottom Layer
MU Middle Layer
Integrated Module
Integrated Module
Power Supply
Module
Surge Arrestor
Duplexer
MCU
Combiner
2.2 EQUIPMENT LAYOUT
Shown below is the internal layout of the PS DAS.
Figure 4: Layout of the MU Bottom layer
Figure 5: Layout of the MU middle layer
INSTALLATION GUIDE FOR RH-7W22
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 16
MU Top Layer
RU底层
Optical Module
FSK Module
Integrated Module
Integrated Module
Power Supply
Module
Surge Arrestor
Figure 6: Layout of the MU top layer
Figure 7: Layout of the RU Bottom layer
INSTALLATION GUIDE FOR RH-7W22
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 17
Optical Module
Adaptor Module
FSK Module
Duplexer
Combiner
Figure 8: Layout of the RU top layer
2.3 EQUIPMENT CONSTITUTION
The typical PS DAS unit consists of the following components:
Power Amplifier (PA): It provides power amplification for both the UL and DL branches.
Main Control Unit (MCU): The MCU is used to monitor and control the operation of the repeater. It also
provides the communication interface for remote control and status indication. LED indicators provide the
operation status of the MCU.
Duplexer: The DPX is located near the MT and DT terminals and permits the uplink and downlink signals to
share a common antenna.
Digital Integrated Module and Power Amplifier: Consists of the Power Conversion module, RF module,
digital process module and monitoring modules. The Power Conversion module converts +28V DC voltage into
+9VJK and +9VRF. +9VJK, +9VRF are supplied to the monitoring unit, and the RF unit in the integrated module
separately. The RF module amplifies and converts the RF signal to IF signal. The Digital process module
converts the IF signal into baseband signal via AD conversion and extraction, and filtering. After that, the IF
signal will be amplified and converted to an RF signal by the RF module for RF filtering and amplification. The
Monitoring module monitors and controls the system parameters and is the interface for both remote
monitoring and local commissioning.
Power Supply Unit (PSU): The PSU converts the input voltage into a stable DC supplyto provide power for
the internal functional modules.
Optical module: Completes optical signal and RF signal conversion.
INSTALLATION GUIDE FOR RH-7W22
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 18
3 INSTALLATION
3.1 WARNINGS AND ALERTS
Radio Frequency Energies
There may be situations, particularly for workplace environments near high-powered RF sources, where
recommended limits for safe exposure of human beings to RF energy could be exceeded. In such cases,
restrictive measures or actions may be necessary to ensure the safe use of RF energy.
High Voltage
The equipment has been designed and constructed to prevent, as far as reasonably practicable danger. Any
work activity on or near equipment involving installation, operation or maintenance must be, as far as
reasonable, free from danger.
Where there is a risk of damage to electrical systems involving adverse weather, extreme temperatures, wet,
corrosive or dirty conditions, flammable or explosive atmospheres, the system must be suitably installed to
prevent danger.
Protective Earthing
Equipment provided for the purpose of protecting individuals from electrical risk must be suitable for the
purpose and properly maintained and used.
Handling Precautions
This covers a range of activities including lifting, lowering, pushing, pulling, carrying, moving, holding or
restraining an object, animal or person from the equipment. It also covers activities that require the use of force
or effort, such as pulling a lever, or operating power tools.
Where some of the abovementioned activities are required, the equipment must be handled with care to avoid
being damaged.
Electrostatic Discharge (ESD)
Observe standard precautions for handling ESD-sensitive devices. Assume that all solid-state electronic
devices are ESD-sensitive. Ensure the use of a grounded wrist strap or equivalent while working with
ESD-sensitive devices. Transport, store, and handle ESD-sensitive devices in static-safe environments.
INSTALLATION GUIDE FOR RH-7W22
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 19
3.2 SITE PLANNING CONSIDERATIONS
3.2.1 SITE PLANNING
Site Considerations
Outdoor equipment are designed to be waterproof, rainproof, and with snow protection. Temporary protection
should be taken when the equipment enclosure is opened for installation or maintenance in an outdoor
environment. The equipment must not be opened for installation or maintenance in bad weather (e.g. gale,
storm rainfall, extreme temperatures and high humidity)
Installation Location
Mounting surface shall be capable of supporting the weight of the equipment.
In order to avoid electromagnetic interference, a proper mounting location must be selected to minimize
interference from electromagnetic sources such as large electrical equipment.
Environmental
Humidity has an adverse effect on the reliability of the equipment. It is recommended to install the equipment in
locations having stable temperature and unrestricted air-flow.
The installation location for the product should be well ventilated. The equipment has been designed to operate
at the temperature range and humidity level as stated in the product specifications in the datasheet.
Direct sun light exposure to the equipment should be avoided. Provide additional shelter if necessary.
Power Supply
The power supply unit (PSU) provides power to all modules within the equipment. Depending on the product
variant, it is recommended that the PSU be operated on a dedicated circuit breaker or fused circuit.
Grounding Requirement
Verify that the equipment has been well grounded. This includes antennas and all cables connected to the
system. Ensure lightning protection for the antennas is properly grounded.
Cable Routing
Depending on equipment configuration, a variety of types of cables are required. Where applicable, ensure
cables are properly routed and secured so that they are not damaged.
Manual Handling
During transportation and installation, take necessary handling precautions to avoid potential physical injury to
the installation personnel and the equipment.