Columbia Products 56WAL, 56WAL-1.0, 56WAL-0.5, 56WBL, 56WBL-1.0 Operating Manual

...
Page 1
HANDS-FREE WALL MOUNTED WASH STATIONS
AC OR BATTERY POWERED
Operating Manual for Three-Person Hands-Free Wall Mounted Wash Stations
AC Models 56WAL, 56WAL-1.0 and 56WAL-0.5
Battery Models 56WBL, 56WBL-1.0 and 56WBL-0.5
1
Columbia does not recommend use with harsh chemicals.
NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.
Page 2
COLUMBIA SPECIFICATIONS
HANDS-FREE WALL MOUNTED WASH STATIONS
AC OR BATTERY POWERED
2
Parts List
(1) Wall mount wash station
(3) AC or Battery powered sensor faucet assembly
(2) Wall-mounting brackets
(2) Support brackets
(3) Mixing check valve
(1) Strainer assembly with basket
Installation Instructions
Step 1
1. Establish sink location on the wall.
2. Determine desired height for the top of the backsplash from finished floor and draw a level line which will be the top edge of the wall mounting bracket.
3. Hold the wall mounting bracket against the wall and mark the wall where the holes are. Drill holes and secure bracket to the wall as shown in illustration A. Screws are not provided.
Step 2
1. Install strainer assembly.
2. Install faucets to the sink following the instructions provided with sensor unit.
3. Attach supply tube with elbow to back of faucet.
4. Install mixing check valve and compression fitting to control box of each sensor faucet.
Step 3
1. Position the sink onto wall bracket.
2. Loosely attach support brackets under sink and push against wall then mark holes for drilling as shown in illustration B.
3. Remove support brackets from sink and drill holes for mounting fasteners (not provided).
4. Re-mount support brackets to sink and fasten to wall.
Step 4
1. Connect waste line to strainer assembly (s).
2. Mount sensor control box at desired location on wall.
3. Connect power line from sensor to control box.
4. Attach supply tube from faucet to control box.
5. Connect hot and cold water from the source to mixing check valve (s).
6. Remove aerator from the spout assemblies and flush water system. (see step 7 sensor installation instructions)
7. Check connections for leaks.
8. Replace aerator onto the spout (s).
9. We recommend sealing top of backsplash to wall as shown in illustration C.
Tools Required
Tape Measure
Adjustable Wrench
Drill Motor and Drill Bits
Pipe Wrench
Level
Safety Glasses
Screw Drivers: 1 Phillips & 1 Standard
Pencil
Socket Wrench
Illustration A
Illustration B
1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191 www.columbiasinks.com email: info@columbiasinks.com
Illustration C
©2018 Columbia Products
Page 3
COLUMBIA SPECIFICATIONS
56 Wall
HANDS-FREE WALL MOUNTED WASH STATIONS
AC OR BATTERY POWERED
3
1.5” (38mm)
.437” (6mm)
.75” (19mm) slot
.437” (6mm)
Top
60” (1524mm)
(267 mm)
57” (1448mm)
30” (762mm)
10.25”
2” drain hole
.5” R
(12.7mm)
30” (762mm)
Front Side
.5” R
(12.7mm)
dia. hole
(407mm)
wall hanger
(254mm)
8” (203mm)
4” (101.6mm)
4” (101.6mm)
2” (51mm)
16.5”
20”
(508mm)
1.5” (38mm)
10”
1.5” (38mm)
35” (889mm)
suggested
floor to rim
height
20” (508mm)
2” (51mm)
7.5” (191mm)
45º
Hole Configurations
11”
(279.4mm)
.875” (22mm)
dia. holes (3)
19”
(482.6mm)
49.5” (1,257.3mm)
19”
(482.6mm)
11”
(279.4mm)
6.75” (171mm)
Wall Mounting Detail
1.5” (38mm)
2” (51mm)
.25” dia. hole
wall hanger
back splash
1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191 www.columbiasinks.com email: info@columbiasinks.com
©2018 Columbia Products