Columbia SANI-LAV N2F, SANI-LAV N2F48, SANI-LAV N2FS, SANI-LAV N2FS4 User Manual

Model N2F Foamer-Sanitizer Series
INDUSTRIAL SPRAY FOAMER/SANITIZER
1
Model N2F Model N2FS
Model N2F48 Model N2FS4
COLUMBIA SPECIFICATIONS MODELS N2F AND N2F48
Parts List
(1) Model N2 spray nozzle
(1) Model N2FC aluminum coupler
(1) Model N2FL or N2F48L foamer lid kit (includes suction tube and foot strainer)
(1) Model N2FSL or N2FSL4 sanitizer lid kit (includes suction tube and foot strainer)
(1) 96 oz. or 48 oz. container
(1) Model N2FM metering tip kit with 15 colored tips (see chart below)
Operation
1. Unscrew the lid assembly from container.
2. Use the chart below to select a metering tip.
3. Press the tip firmly into the bottom of the lid assembly. Then install the suction tube onto lid over the metering tip. (Illustration A and B)
3. Fill the container with concentrate. Screw the lid assembly securely onto container to prevent any accidental spilling.
4. Make sure that the aluminum quick connect coupler is attached to the spray nozzle model N2. (Illustration C)
5. Connect hose with ¾” GHT male threads to model N2 spray nozzle inlet. Turn on the water supply with minimum of 25 PSI.
6. Hold the spray nozzle handle in one hand and the container in the other and squeeze the spray nozzle handle to begin.
When using this product you should always:
1. Wear protective clothing and eyewear when dispensing chemicals or other materials or when working in the vicinity of all chemicals, filling or emptying equipment or changing metering tips.
2. Observe safety and handling instructions of the chemical manufacturers.
3. Direct discharge away from you or other persons or into approved containers.
4. Dispense cleaners and chemicals in accordance with manufacturer’s instructions. Exercise caution when maintaining your equipment.
5. Clean all equipment after each use in accordance with instruction sheet.
6. Re-assemble equipment according to instruction procedures. Be sure all components are firmly screwed or latched into position.
7. Use only to tap water outlets with a maximum psi of 85.
INDUSTRIAL SPRAY FOAMER/SANITIZER
Illustration A
Illustration B
2
Metering Tip Selection
The below listed dilution ratios were found using 40 PSI, cold water and water-thin viscosity (1.0 CP). Ratios will vary based on PSI, water and ambient temperature and viscosity. If no tip is listed then the dilution ratio falls between those shown.
Tip Color Hole Dia. Size in Drill No. Ratio Oz. Per Gal.
No Tip 12:01 10 Gray .128 30 * * Black .098 40 * * Beige .070 50 * * Red .052 55 * * White .043 57 14:01 9 Blue .040 60 16:01 8 Tan .035 65 18:01 7 Green .028 70 26:01:00 5 Orange .025 72 32:01:00 4 Brown .023 74 * * Yellow .020 76 42:01:00 3 Aqua .018 77 * * Purple .014 79 64:01:00 2 Pink .010 87 128:01:00 1
1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191 www.columbiasinks.com email: info@columbiasinks.com
Illustration C
Loading...