If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life
Safety Instructions - Read Before Installing & Operating Equipment
:
g
n
i
n
r
a
W
r
a
W
r
a
W
A) This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.
B) Before operating equipment smell around the appliance area for gas. Be sure to smell next to the floor because some gas (specifically L.P.) is heavier than air and will settle to the flo or.
C) If you smell gas:
1) Do not try to light any appliance
2) Do not touch any electric switch
3) Do not use any phone i n the building
4) Contact your gas supplier immediately using a ne i ghbor’s phone
5) Follow the gas supplier’ s instructions
D) Use only your hand to push in or turn the gas cont r ol knob. Never use too ls. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or atte mpted repair may result in afire or explosion.
E) Do not use appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under w ater.
:
g
n
i
n
:
g
n
i
n
Operating Instructions – Quick Reference
1) Read all instructio ns pr ior to operating equipment.
2) Set the thermostat to the lowest setting.
3) Turnoff all electric power to the appliance.
4) This device is equipped with an ignition devic e which automatically lights the burner. Do not try to light the burner by hand.
5) If the gas control knob is not in the “OFF” position, turn knob clockwise to the “OFF” position.
6) Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, stop immediately.
7) Turn gas control knob counter-clockwise to “ON”.
8) Turn on all electric power to the appliance.
9) Set the thermostat to the desired setting.
10) If the appliance does not operate, follow the instructions.
Turning Gas Off To Appliance – Quick Reference
1) Set the thermostat to lowest setting.
2) Turn off electric power to the appliance if service is to be performed.
3) To turn off gas to the appliance, turn the gas control knob clockwise to “OFF”.
Contents
Safety Instructions i Product Features 1 Installation 3 Start Up 6 Maintenance 8 Trouble Shooting 9 Parts 12
Over fifty years of engineering and product development have gone into your new Columbia boiler. Its quality and design are unsurpassed. Properly installed and maintained, it will provide many years of efficient and dependable operation. Please read this instruction manual carefully. The information contained within is designed to help you maintain peak performance from your unit.
Product Features
ASME Coded Boiler Registered with National Board
Factory Mounted / Wired Burner and Controls
Fully Insulated Heat Exchanger with Powder-Coated Cabinet
Packaged with Standard Five Gallon per Minute Tankless Coil (Domestic Hot Water)
Equipped with Triple Aquastat, Circulator, Temperature / Altitude Gauge and Gas Regulator
Outfitted with Additional Orifices to Achieve a Variety of Heat Inputs
Provided with a Lifetime Limited Warranty
EMG-31 120
EMG-31 140
EMG-31 160
Nat.
L.P.
Nat.
L.P.
Nat.
L.P.
Factory
Set
Factory
Set
Factory
Set
Factory
Set
Factory
Set
Factory
Set
AFUE
Input (Btu/Hr)* 120,000 140,000 160,000 IBR Heat Capacity (Btu/Hr) 88,000 101,000 114,000 Valve Capacity (Lbs/Hr) 160 160 160 Max Water Pressure (Psi) 30 30 30 Burner Model Carlin EZ-Gas Carlin EZ-Gas Carlin EZ-Gas
Fuel Type
Gas
Gas
Gas
Gas
Gas
Gas
Orifice Size 0.242” 11/64 0.250” 13/64 0.290” 7/32 Fuel Input Rate (Cfm) 1.95 0.79 2.28 0.95 2.60 1.06 Max. Inlet Pressure (“W.C.) 11” 11” 11” 11” 11” 11” Min. Inlet Pressure (“W.C.) 5” 5” 5” 5” 5” 5” Manifold Pressure (“W.C.) 3.5” 3.5” 3.5” 3.5” 3.5” 3.5”
Head Position Air Shutter 31% 30% 45% 42% 65% 78%
Draft Over Fire (“W.C.) -0.02” -0.02” -0.010” -0.02” -0.005” -0.005” Draft in Stack (“W.C.) -0.02” -0.02” -0.02” -0.015” -0.02” -0.02” CO2 Reading 9.0% 11.0% 9.0% 11.0% 9.0% 11.0%
83.8% 83.8% 83.0% 83.0% 82.2% 82.2%