Columbia CV16 User Manual

CENTRAL VACUUM SYSTEM
USER MANUAL
GB
CV16
1
2
3
4
5
6
7
8
9
10 11
12
13
12 00
58
61
AMETE
K
Mode
l
1
80 0
61
> > > >
1. Vent - inlet
2. Vent - outlet
3. Control cable
4. Power supply indicator
5. Overcurrent fuse
6. Power supply cable
7. Wall support
8. Inlet
9. Receptacle
10. Ground screw
11. Mode switch
- manual/auto
12. Outlet
13. Hose socket
Negative pressure KP 25,5 30 32
Category
Housing Engine
COLUMBIA VAC CENTRAL VACUUM SYSTEM
hybrid cyclonic
stainless steel
Power (W)
Power supply 230V ~ 50Hz
Hose socket
Yes Yes Yes
Suction power (Airwatt) 340 510 625
Receptacle capacity (L) 20 20 20
Weight (kg) 7,6 9,6 9,8
Size (mm) (mm) 280x840 280x910 280x910
Noise level (3m)(db)
Filtration system (1)
Nano ltration system:
Self-cleaning function Resistant No replacement required No operation costs
CV12 CV16 CV18
Silencer
Maximum installation length (m) 45 60 75
Maximum socket number 5 7 9
Yes Yes Yes
1600
The vacuum cleaner is equipped with a double system of air intake and air outlet. After plugging in the vacuum cleaner to the mains, the unused intake/outlet should be closed with the supplied cap.
OPERATION AND SERVICE MANUAL
Congratulations! Welcome among the owners of central vacuum systems - the best class of cleaning appliances. We say “goodbye” to the old-fashioned sweepers. There is no need to lug heavy vacuum cleaners with you. The central vacuum changes the approach to everyday cleaning. It is easy to operate and versatile. The central vacuum is quiet and dust free. It improves the process of vacuuming while helping to keep the environment cleaner and healthier. Before using the central vacuum system, read this manual thoroughly. Learning how to operate the system properly will allow for a long-term trouble-free work with the vacuuming system. The
central vacuum system is up to ve times more efcient
than traditional vacuum cleaners. Our system collects virtually 100% of dusts, mites and pollens, as well as other
allergens from the oors, furniture and other surfaces
and supplies the collected material to the unit, which is usually located in the utility room, while preserving the high quality of air in the living areas.
The Central Vacuum System is composed of: a central power unit, a system of pipes, valves and ttings.
See the section below..
CENTRAL POWER UNIT
The central power unit may be installed in a garage or a utility room to reduce the noise and the impact on living areas. The location of the main unit should be a dry, well­ventilated place.
UWAGA
- The motor does not need lubrication. Bearings are permanently sealed and lubricated.
- Motor brushes should be checked by the authorized service after 500 hours of operation.
Clean the central unit with a soft cloth. Note: do not use
liquid cleaners due to the risk of electric shock.
The central power unit is of a suspended type, the receptacle for dust (dirt) is located on the bottom. The receptacle can be dismantled and the dirt removed. We suggest emptying the receptacle every 3-4 months. To ensure the highest performance it is recommended to empty the receptacle when it is half full. Our central power units are adapted for the voltage of 230V~50Hz, we recommend using sockets higher than 10 AMP with a single individual circuit. The main power unit is supplied
along with a self-cleaning lter.
During standard operation you do not need to clean or replace it.
Nevertheless, check the lter once
a month for damage or fractures.
If the lter is damaged by glass
or other sharp objects, replace it immediately. Do not use the vacuum cleaner with
a damaged lter. Do not vacuum
any substances that may solidify as
it may clog the lter. If you need to clean the lter, perform the following ve easy steps:
a) Remove the dirt receptacle. b) Wrap a large plastic trash bag around the lower part of the power unit (as illustrated).
c) Grab the bottom of the lter. Shake
vigorously. Dirt will drop into the bag.
The vacuum cleaner should be mounted on the wall in the
distance no smaller than:
- 30 cm from the ceiling
- 30 cm from the corner of the wall
- 70 cm from the oor
d) Carefully remove the plastic bag from the unit. Empty the dirt receptacle into the bag. e) Replace the dirt receptacle on the unit. Remember that any spilt dirt can be easily vacuumed by attaching the hose to the utility inlet. Do not shake the main unit. Do not place anything on
the top of the unit as this restricts the inow of the cooling
air to the motor and may result in its overheating.
NOTE
1) The mode switch (11) should be set in the AUTO mode during everyday use.
2) Always close the vacuum inlets when the unit is not in operation.
3) For safety reasons, the control circuit operates at 12V. Prevent any short-circuits. It is recommended to unplug the main power unit during the house renovation.
4) If during the usage of the system the user discovers that the suction pressure is lower, check if all the vacuum inlets are closed and if they are not damaged and if the
receptacle is full or the lter dirty.
COLUMBIA VAC CENTRAL VACUUM SYSTEM
PL
THE CENTRAL VACUUM CLEANER PACKAGE INCLUDES
CENTRAL POWER UNIT
GUARANTEE CERTIFICATE
USER MANUAL
SILENCER CONNECTOR (1)
BAND CLIP (4)
SILENCER
HANGER
SILENCER MOUNTING BRACKET (1)
CONNECTION HOSE 30cm (2)
CONTROL CABLE COUPLING (2)
PLASTIC PLUG (4)
SCREW M5X35 (4)
Operation of the vacuum cleaner - individual steps (using the hose with a push-button in the handle):
1. Insert a selected vacuum brush or attachment on the hose.
2. Connect the hose to one of wall sockets.
3. Turn on the switch on the handle. The machine starts.
4. When vacuuming is completed, turn off the switch on the handle, disconnect the hose from the socket.
Operation of the vacuum cleaner - individual steps (using the hose without a push-button in the handle):
1. Insert a selected vacuum brush or attachment on the hose.
2. Connect the hose to one of wall sockets. The machine starts.
3. When vacuuming is completed, disconnect the hose from the socket.
NOTE: When disconnecting the hose, it is recommended
to hold the inlet door open for a few seconds until the suction pressure has decreased.
The vacuum cleaner is equipped with a hose socket (13) located on the housing of the appliance. To use the socket, connect a hose to it and then turn the vacuum cleaner on with a switch (11).
IMPORTANT SAFETY INFORMATION
- before the rst use, read this entire user manual thoroughly
- plug in the connecting cable to an outlet with parameters
specied in the manual
- keep the power supply cable away from heated up surfaces
- do not pick with the vacuum cleaner the following
materials:
- hot ash,
- cigarette butts and matches,
- sharp objects (glass pieces),
- gypsum, cement, stone dust and our,
- debris,
- water and other liquids
- do not start the unit when the lter is damaged
- do not cover vents. Keep the appliance away from dusty rooms or places with large amount of hair or other factors
reducing the airow.
- do not use the vacuum cleaner for vacuuming the wet surface of carpets, e.g. after washing with a shampoo. Wait until the foam dries up and the vacuumed surface is dry do not use to vacuum people or animals, and in particular do not approach the suction attachments to eyes and ears always unplug the appliance by pulling by the plug and not by the power supply cord protect the vacuum cleaner against moisture, do not put any vessels with liquid on it, never leave the operating vacuum cleaner without supervision
COLUMBIA VAC CENTRAL VACUUM SYSTEM
- the appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, unless they are supervised by a person responsible for their safety. Make sure that children do not play with the equipment
- extra caution is required when the appliance is used near children
- do not use the vacuum cleaner without lters and the
dirt receptacle
- do not stand on the suction hose
- do not put heavy objects on the suction hose
- do not block the inlet opening
- do not immerse the appliance in water
- the appliance is intended only for use in a household do not use in open air,
- use only with original accessories supplied with the appliance
- before each cleaning and emptying of the receptacle, unplug the appliance
- do not use when the power cable is damaged, or when the appliance was damaged otherwise. Repairs of the equipment can only be performed by an authorized servicing point; a list of servicing points is in the appendix and on the website www.columbiavac.pl,
- repairs of the equipment can only be performed by an authorized servicing point. Any modernizations or the use of non-original spare parts or elements of the appliance is prohibited and may cause a serious hazard to the user
- DO NOT use the appliance for purposes other than the intended use and in the manner incompatible with this manual
- The company Columbiavac Europe Sp. z o. o. shall bear no responsibility for any possible damages resulting from the improper usage of the appliance
ENVIRONMENTAL PROTECTION
- the appliance is made of materials which can be reprocessed or recycled
- it should be handed over to a relevant point which deals with the collection and recycling of electric and electronic appliances.
TECHNICAL SUPPORT
Thank you for the purchase of the product. In case of any unexpected problems or when you need a consultation regarding our products, we encourage you to contact our service centre or technical personnel who will provide you with the required assistance.
COLUMBIA VAC CENTRAL VACUUM SYSTEM
www.columbiavac.com
ZENTRALSTAUBSAUGERANLAGE
Bedienungs- und Serviceanleitung
CV16
D
1
2
3
4
5
6
7
8
9
10 11
12
13
12 00
58
61
AMETE
K
Mode
l
(
W)
1
80 0
61
> > > >
1. Ventilationsöffnung - Einlass
2. Ventilationsöffnung - Abluft
3. Steuerleitung
4. Kontrollleuchte ­Stromanschluss
5. Überstromschutz
6. Speisekabel
7. Wandhalterung
8. Sauganschluss
9. Schmutzbehälter
10. Erdungsschraube
11. Modus-Schalter ­manuell/auto
12. Luftauslass
13. Zusätzliche Saugdose
Unterdruck WS 25,5 30 32
Kategorie Gehäuse
Motor
COLUMBIA VAC ZENTRALSTAUBSAUGERANLAGE
Hybrid-Zyklon
nichtrostender Stahl
Leistung
Speisespannung 230V ~ 50Hz
Zusätzliche Saugdose Ja Ja Ja
Saugkraft (AirWatt) 340 510 625
Schmutzbehälterinhalt (L) 20 20 20
Gewicht (kg) 7,6 9,6 9,8
Abmessungen (mm) 280x840 280x910 280x910
Schallpegel (3m) (db)
Filtersystem ( 1 )
Nono-Filtersystem:
mit Selbstreinigungsfunktion widerstandsfähig bedarf keinen Austausch verursacht keine Nutzkosten
CV12 CV16 CV18
Schalldämpfer
Maximale Länge der Anlage 45 60 75
Maximale Anschlusszahl 5 7 9
Ja Ja Ja
1600
Der Staubsauger ist mit einem beidseitigen Anschlusssystem für Lufteinlauf ausgestattet. Nach dem Anschluss des Staubsaugers an die Installation soll der ungebrauchte Einlauf mit der im Set beiliegenden Blende verblendet werden.
Loading...
+ 22 hidden pages