RGBW
Coloronix, Inc.
5461 West Jefferson Boulevard
Los Angeles, California 90016
(323) 677-4242
http://www.rgbw.com
MODULAR
LIGHTING
MANUAL
Page 1 – Coloronix RGBW Modular Lighting Manual V.2.2
Coloronix, Inc.
© 2011 Coloronix, Inc. All rights reserved.
According to copyright laws, this manual may not be copied—partially, or wholly—
without the written consent of Coloronix, Inc.
Despite full effort to avoid any clerical or printing inaccuracies, Coloronix, inc. accepts
no responsibility for any such inaccuracies to be found in this manual.
Coloronix, Inc.
5461 West Jefferson Boulevard
Los Angeles, California 90016
Tech Support: (909) RGBW-555
http://www.rgbw.com
Coloronix and the Coloronix logo are brands of Coloronix, Inc.
Any non-Coloronix brands or products found in this manual are not endorsed, branded,
or recommended for use by Coloronix, Inc.; rather, they are only references for
informational purposes. Coloronix has no responsibility for these products in regards
to either performance or use.
Page 2 – Coloronix RGBW Modular Lighting Manual V.2.2
Contents
Summary 4
Introduction 4
Scope 4
Who is this manual intended for? 4
Additional Supplies 4
Safety 5
Hazard Icon Key 5
Specifications 5
Planning for Installation 6
Unpacking 6
Preparation 6
Points to Consider About Data 6
Quick Step-by-Step Instructions 6
Setting Color Mode 7-9
DMX Color Mode 7-8
ColorRay Stand Alone Mode 9
Installing Mini Data Enabler 10-12
Wiring Diagram 11
Data Connection 12
Troubleshooting Guide 13-14
Further Troubleshooting 14
Replacing Failed Fixture 14
Warranty Information 15
Page 3 – Coloronix RGBW Modular Lighting Manual V.2.2
Summary
Introduction
RGB/RGBW Color Changing Modular Lights are active, top-of-the-line color changing
fixtures. They draw on solid-state elements in order to produce highlights and washes
in architectural spaces.
More specifically, “RGBW” is an acronym for “Red, Green, Blue, and White”. RGBW
LED color mixing luminaires have the potential to produce 4.3 billion colors, and 16.7
million white light tones.
When installed and operated according to this manual, these downlights will operate
safely and dependably for their rated lifespan.
These mini-data enablers require a USITT DMX 512 control signal on four consecutive
channels total. The unit includes a DATA OUT output for connection to additional units
or other DMX512 devices. A ColorRay Signal from the internal stand-alone controller
or external controller can be used as well.
The modular lights are UL 1598 damp location rated for use in indoor or outdoor
environments.
Scope
The purpose of this manual is to properly install and use modular color changing lights
at peak performance
This manual must be complimented by additional references, consultation from
qualified professional(s), and observance of state and local codes and regulations. This
rule applies to any interior structure, exterior structure, or environment.
Therefore, it is important to:
warnings in this manual when installing or using this product.”
.
“please read and comply with all instructions and
Who Is This Manual Intended for?
This manual is intended for electrical contractors, electrical engineers, and licensed
electricians.
Additional Supplies
DMX control cable: Belden© 9841 or CAT5 RJ45 Cable
DMX512 compatible controller or Coloronix ColorRay Device (optional)
Page 4 – Coloronix RGBW Modular Lighting Manual V.2.2
Safety
• Do not make any inflammable liquids, water or metal objects enter the unit.
• To prevent or reduce the rise of electric shock, DO NOT OPEN THE TOP COVER.
• This unit must only be operated by adults; do not allow children to play with it.
• There are no user serviceable parts inside this unit. Do not attempt any repairs yourself.
• Should you experience any problems during use, please contact your local dealer immediately.
• Do not discard the shipping carton in the trash. Please recycle whenever possible.
• Always consult authorized personnel for any repairs and maintenance.
Hazard Icon Key:
The “
The “
The “
damage.
DANGER” icon means avoiding
WARNING” icon means avoiding this warning may result may in serious injury, or death.
CAUTION” icon means not exercising caution here may result in minor to moderate injury, or property
pending
danger will result in serious injury, or death.
The Precautions are:
DANGER: Not turning off the main power before wiring, installing, connecting, or disconnecting this product
may result in serious injury, or death.
WARNING: Not following NEC codes, local codes, or consulting a certified professional may result in property
damage, serious injury, or death.
WARNING: Not following instructions, or safety labels may result in property damage, or serious injury.
WARNING: Modifying, servicing, or ignoring these safety indications may void the warranty.
WARNING: Inspect product before use. DO NOT use if damaged.
WARNING: Install safety cables per local and structural engineer’s code.
CAUTION: Hot swapping, not turning off fixtures before connection or disconnection, will void the warranty,
and damage property.
CAUTION: Do not go beyond the specified voltage, input current, maximum number of fixtures, or run length.
Specifications
Power Input: Direct 24VDC
Environment: Dry location
Estimated Life: 25,000 Hours.
Temperature Rating: 0°C - 70°C (32°F -158°F)
Safety: ETL Listed Complies to UL1598 and ANSI/UL 8750 (pending)
Weight: 250g (0.55 lbs)