colorFabb FL6000 operation manual

SAFETY DATA SHEET
Eastman Amphora(TM) Flex 3D Polymer FL6000
Version
2.0
Revision Date: 08/04/2016
SDS Number: 150000107028
Date of last issue: ­Date of first issue: 08/04/2016
SDSUS / PRD / 0001
Product name
:
Eastman Amphora(TM) Flex 3D Polymer FL6000
Product code
:
000000000050198002
Company name of supplier
:
Eastman Chemical Company
Address
:
200 South Wilcox Drive Kingsport TN 37660-5280
Telephone
:
(423) 229-2000
Recommended use
:
Polymer
Restrictions on use
:
None known. Combustible dust
Signal word
:
Warning
Hazard statements
:
If small particles are generated during further processing, han­dling or by other means, may form combustible dust concentra­tions in air.
Precautionary statements
:
Disposal: P501 Dispose of contents/ container to an approved waste dis­posal plant. Chemical name
CAS-No.
Concentration (% w/w)
polyester
111940-18-2
> 99
additive(s)/colorant(s)
proprietary
< 1
SECTION 1. IDENTIFICATION
Manufacturer or supplier's details
Recommended use of the chemical and restrictions on use
SECTION 2. HAZARDS IDENTIFICATION
GHS Classification
GHS label elements
Other hazards
None known.
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Components
1 / 9
SAFETY DATA SHEET
Eastman Amphora(TM) Flex 3D Polymer FL6000
Version
2.0
Revision Date: 08/04/2016
SDS Number: 150000107028
Date of last issue: ­Date of first issue: 08/04/2016
SDSUS / PRD / 0001
If inhaled
:
Move to fresh air. Treat symptomatically. If symptoms persist, call a physician.
In case of skin contact
:
Wash off with soap and water. If symptoms persist, call a physician. Cool skin rapidly with cold water after contact with molten material. Do not peel solidified product off the skin. Burns must be treated by a physician.
In case of eye contact
:
In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
If swallowed
:
Seek medical advice.
Most important symptoms and effects, both acute and delayed
:
The molten product can cause serious burns. Notes to physician
:
Treat symptomatically.
Suitable extinguishing media
:
Water spray Dry chemical Carbon dioxide (CO2)
Unsuitable extinguishing media
:
Do not use a solid water stream as it may scatter and spread fire.
Specific hazards during fire­fighting
:
Avoid generating dust; fine dust dispersed in air in sufficient concentrations, and in the presence of an ignition source is a potential dust explosion hazard.
Hazardous combustion prod­ucts
:
No hazardous combustion products are known Further information
:
Minimize dust generation and accumulation.
Special protective equipment for firefighters
:
Wear an approved positive pressure self-contained breathing apparatus in addition to standard fire fighting gear.
Personal precautions, protec­tive equipment and emer-
:
Wear appropriate personal protective equipment. Local authorities should be advised if significant spillages
SECTION 4. FIRST AID MEASURES
SECTION 5. FIREFIGHTING MEASURES
SECTION 6. ACCIDENTAL RELEASE MEASURES
2 / 9
SAFETY DATA SHEET
Eastman Amphora(TM) Flex 3D Polymer FL6000
Version
2.0
Revision Date: 08/04/2016
SDS Number: 150000107028
Date of last issue: ­Date of first issue: 08/04/2016
SDSUS / PRD / 0001
gency procedures
cannot be contained.
Environmental precautions
:
Avoid release to the environment.
Methods and materials for containment and cleaning up
:
Sweep up and shovel into suitable containers for disposal.
Advice on protection against fire and explosion
:
Minimize dust generation and accumulation.
Advice on safe handling
:
Wash thoroughly after handling. Use only in area provided with appropriate exhaust ventilation. Minimize dust generation and accumulation.
Conditions for safe storage
:
Keep tightly closed.
Engineering measures
:
Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to con­ditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure lim­its have not been established, maintain airborne levels to an acceptable level.
Respiratory protection
:
Use respiratory protection unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines. Wear respiratory protection when its use is identified for cer­tain contributing scenario.
Remarks
:
Wear suitable gloves. When handling hot material, use heat resistant gloves.
Eye protection
:
Safety glasses Wear a face shield when working with molten material.
Skin and body protection
:
Wear suitable protective clothing. Protective measures
:
Ensure that eye flushing systems and safety showers are
SECTION 7. HANDLING AND STORAGE
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters
Contains no substances with occupational exposure limit values.
Personal protective equipment
Hand protection
3 / 9