Collingwood LBASDHS Installation Instructions

LENTUS LOW BAYS  MICROWAVE SENSOR / DÉTECTEUR HYPERFRÉQUENCE  LUMINAIRE INDUSTRIEL LENTUS / LENTUS DECKENSTRAHLER  MIKROWELLENSENSOR
INSTALLATION INSTRUCTIONS / CONSIGNES D’INSTALLATION / EINBAUANLEITUNG
Fig. 1 / Abb. 1
Fig. 2 / Abb. 2 - Remote distance / Portée de la télécommande / Reichweite der Fernbedienung
EN
Installation
1. Isolate the mains supply prior to wiring.
2. The sensor settings are controlled by remote controller. Each sensor has to be set up individually.
Note: Remote controller sold separately.
3. Loosen the screws retaining the side panel of the low bay and pull it to remove (Fig. 1).
5. Reattach the side panel and tighten the screws.
6. Connect the sensor to the low bay luminare. (Fig. 3)
Sensor settings and data
• Input voltage 200 - 240V AC
• Detection angle 360˚ - ceiling installation, 150˚ - wall installation.
• Mounting height 3 - 15m.
Detection Area (15m max radius)* *Mounting height and speed of the object moving under the sensor will affect the functional detection area (see Fig. 4)
Fig. 3 / Abb. 3
220 - 240 V AC 50 / 60 Hz
Green / Yellow / Vert / Jaune : terre / Grün-gelb (Schutzleiter)
Brown Live / Marron : phase / Stromführend
Blue Neutral / Bleu : neutre / Neutral
Fig. 4 / Abb. 4 - Detection pattern example / Exemple de détection / Beispiel für Erfassungsmuster
Fast Walk / Marche rapide /
Schnelle Bewegung
10 8 6 4 2 0 2 4 6 8 10 15 12 9 6 3 0 3 6 9 12 15
Mounting height: 9M / Hauteur de montage: 9m / Installationshöhe: 9m
FR DE
Installation
1. Avant toute intervention, coupez le courant au disjoncteur.
2. Les paramètres du détecteur sont contrôlés par la télécommande. Chaque détecteur doit être configuré individuellement.
Remarque: la télécommande est vendue séparément.
3. Desserrez les vis retenant le panneau latéral du luminaire industriel et tirez pour le retirer (Fig. 1).
4. Retirez la partie défonçable et installez le détecteur.
5. Repositionnez le panneau latéral et serrez les vis.
6. Connectez le détecteur au luminiare industriel. (Fig. 3)
Données et réglages du détecteur
• Tension d’entrée 200 - 240V AC
• Faisceau de détection 360˚ pour une installation au plafond, 150˚ pour une installation murale.
• Hauteur de montage 3 - 15m.
Surface de détection (périmètre max 15m)* *La hauteur de montage et la vitesse de déplacement de l’objet sous le détecteur affecteront la surface de détection (Fig. 4)
Blue / Bleu / Blau
Red / Rouge / Rot
Brown / Marron / Braun
Grey / Gris / Grau
Purple / Violet / Lila
100% 75% 50% 25%
Slow Walk / Marche lente /
Langsame Bewegung
100% 75%
50% 25%
Green / Yellow / Vert / Jaune / Grün-gelb Blue / Bleu / Blau AC N
Brown / Marron / Braun AC L
Blue / Bleu / Blau DIM -
Brown / Marron / Braun DIM +
Low Bay / Luminaire industriel / Deckenstrahler
Installation
1. Isolieren Sie das Stromnetz, bevor Sie mit dem Verkabeln beginnen.
2. Die Sensoreinstellungen werden über eine Fernbedienung gesteuert. Jeder Sensor wird einzeln eingestellt.
Hinweis: Fernsteuerung separat erhältlich.
3. Lösen Sie die Schrauben am Seitenteil des Strahlers und ziehen Sie es ab (Abb. 1).
4. Entfernen Sie die Plättchen der vorgestanzten Löcher und installieren Sie den Sensor.
5. Setzen Sie das Seitenteil wieder ein und befestigen Sie die Schrauben.
6. Verbinden Sie den Sensor mit der Leuchte des Deckenstrahlers. (Abb. 3)
Sensoreinstellungen und Daten
• Eingangsspannung: 220-240 V Wechselstrom
• Erfassungswinkel: 360° - Deckeninstallation; 150° - Wandinstallation
• Installationshöhe: 3-15m.
Erfassungsbereich: 15 m max. Radius* *Installationshöhe und die Bewegungsgeschwindigkeit des Objekts unter dem Sensor beeinflussen den Erfassungsbereich (siehe Abb. 4)
EN
t +44 (0) 1604 495 151 f +44 (0) 1604 495 095 e sales@collingwoodgroup.com w collingwoodlighting.com
FR
t +33 (0) 4 816 816 10 f +33 (0) 4 816 816 11 e ventes@collingwoodgroup.com w collingwoodlighting.com
Collingwood Lighting, Brooklands House, Sywell Aerodrome, Sywell, Northampton NN6 0BT, United Kingdom
CWI 8208 V1
LENTUS LOW BAYS  MICROWAVE SENSOR / DÉTECTEUR HYPERFRÉQUENCE  LUMINAIRE INDUSTRIEL LENTUS / LENTUS DECKENSTRAHLER  MIKROWELLENSENSOR
INSTALLATION INSTRUCTIONS / CONSIGNES D’INSTALLATION / EINBAUANLEITUNG
Remote Control Setting
Button
EN
ON/OFF mode, sensor is disabled. Lights can be switched on/off with remote controller.
Restore factory settings.
Sensor mode, sensor is enabled.
Test 1-10V dimming, lights will dim to minimum, then to maximum and switch back to previous settings.
Override DH –deactivate daylight harvesting sensor. Hold button for 3s, the light will switch off and switch back on with sensor deactivated. DH mode – activate daylight harvesting sensor. Hold button for 3s the light will switch off and switch back on with sensor activated.
Set occupancy light level between 50 and 100%
Predefined settings
Detection
Options
QS1 100% 5min 10min 10% 30Lux Hs QS2 100% 10min 30min 10% Disable Hs QS3 100% 20min 30min 10% Disable Hs
Area
Hold Time
Stand-by
period
Stand-by dim level
Daylight
Sensor
Sensitivity
model
Scene
Quick test with the following settings: detection area - 100%; hold time
- 5s; standby dimming level - 10%; standby period - 0s; daylight sensor
- disable.
Set detection area sensitivity LS – low, HS – high sensitivity
EN
t +44 (0) 1604 495 151 f +44 (0) 1604 495 095 e sales@collingwoodgroup.com w collingwoodlighting.com
FR
t +33 (0) 4 816 816 10 f +33 (0) 4 816 816 11 e ventes@collingwoodgroup.com w collingwoodlighting.com
Daylight sensor
Daylight sensor
Hold time – time period the light remains on once the movement is detected.
Standby dimming level
Detection area
Remote distance (see Fig. 2)
Collingwood Lighting, Brooklands House, Sywell Aerodrome, Sywell, Northampton NN6 0BT, United Kingdom
CWI 8208 V1
LENTUS LOW BAYS  MICROWAVE SENSOR / DÉTECTEUR HYPERFRÉQUENCE  LUMINAIRE INDUSTRIEL LENTUS / LENTUS DECKENSTRAHLER  MIKROWELLENSENSOR
INSTALLATION INSTRUCTIONS / CONSIGNES D’INSTALLATION / EINBAUANLEITUNG
Configuration de la télécommande
Boutons
FR
Mode ON / OFF, le détecteur est désactivé. Les luminaires peuvent être allumés / éteints avec la télécommande.
Rétablir les paramètres d’origine.
Mode détecteur, le détecteur est activé.
Tester la variation 1-10V, les luminaires seront variés au minimum, puis au maximum et reviendront aux paramètres précédents.
Override DH- Désactiver le détecteur de luminosité. Maintenez le bouton pendant 3 secondes, le luminaire s’éteindra et se rallumera avec le détecteur désactivé. Mode DH - activer le détecteur de luminosité. Maintenez le bouton enfoncé pendant 3 secondes, la lumière s’éteindra et se rallumera avec le détecteur activé.
Régler le niveau de luminosité entre 50 et 100%
Réglages prédéfinis
Scènes
Zone de
détection
QS1 100% 5min 10min 10% 30Lux Hs QS2 100% 10min 30min 10% Désactiver Hs QS3 100% 20min 30min 10% Désactiver Hs
Durée
maintenue
Durée
de veille
Niveau de
variation en veille
Détecteur de
luminosité
Type de
sensibilité
Test rapide avec les paramètres suivants: zone de détection 100%; temps de maintien 5s; niveau de gradation en veille 10%; période de veille 0s; capteur de luminosité - désactivé.
Définir la plage de sensibilité de détection LS - faible, HS - haute sensibilité
EN
t +44 (0) 1604 495 151 f +44 (0) 1604 495 095 e sales@collingwoodgroup.com w collingwoodlighting.com
FR
t +33 (0) 4 816 816 10 f +33 (0) 4 816 816 11 e ventes@collingwoodgroup.com w collingwoodlighting.com
Détecteur de luminosité
Détecteur de luminosité
Temps de maintien - période pendant laquelle la lumière reste allumée une fois le mouvement détecté.
Niveau de gradation en veille
Zone de détection
Portée de la télécommande (voir Fig.2)
Collingwood Lighting, Brooklands House, Sywell Aerodrome, Sywell, Northampton NN6 0BT, United Kingdom
CWI 8208 V1
LENTUS LOW BAYS  MICROWAVE SENSOR / DÉTECTEUR HYPERFRÉQUENCE  LUMINAIRE INDUSTRIEL LENTUS / LENTUS DECKENSTRAHLER  MIKROWELLENSENSOR
INSTALLATION INSTRUCTIONS / CONSIGNES D’INSTALLATION / EINBAUANLEITUNG
Einstellung der Fernbedienung
Tast e
DE
ON/OFF-Modus, Sensor ist deaktiviert. Das Licht kann mittels Fernbedienung an-/ausgeschaltet werden.
Auf Werkseinstellung zurücksetzen
Sensor-Modus, Sensor ist aktiviert
Prüfung des 1-10V-Dimmers, Licht dimmt auf das Minimum, dann auf das Maximum und geht auf die vorherige Einstellung zurück.
Override DH – Deaktivierung des Tageslichtsensors. Knopf für 3 Sekunden halten, das Licht schaltet sich aus und wieder an mit deaktiviertem Sensor. DH-Modus – Aktivierung des Tageslichtsensors. Knopf für 3 Sekunden halten, das Licht schaltet sich aus und wieder an mit aktiviertem Sensor.
Einstellen des Belegungslichtniveaus zwischen 50 und 100%
Vordefinierte Einstellungen
Lichtoptionen Erfassungsbereich Haltezeit
QS1 100% 5min 10min 10% 30Lux Hs QS2 100% 10min 30min 10% Deaktivieren Hs QS3 100% 20min 30min 10% Deaktivieren Hs
Standby­Zeitraum
Standby-
Dimmstufe
Tageslichtsensor Empfindlichkeit
Schnelltest mit den folgenden Einstellungen: Erfassungsbereich - 100 %; Haltezeit - 5 Sek.; Stand-by Dimm-Level: 10%; Stand-By Zeitraum - 0 Sek; Tageslichtsensor - deaktiviert.
Empfindlichkeit des Erkennungsbereichs einstellen: LS – niedrige Empf., HS – hohe Empf.
EN
t +44 (0) 1604 495 151 f +44 (0) 1604 495 095 e sales@collingwoodgroup.com w collingwoodlighting.com
FR
t +33 (0) 4 816 816 10 f +33 (0) 4 816 816 11 e ventes@collingwoodgroup.com w collingwoodlighting.com
Tageslichtsensor
Tageslichtsensor
Haltezeit - Zeitraum in dem das Licht eingeschaltet bleibt, wenn Bewegung erfasst wurde.
Standby-Dimmstufe
Erfassungsbereich
Reichweite der Fernbedienung (siehe Abb. 2)
Collingwood Lighting, Brooklands House, Sywell Aerodrome, Sywell, Northampton NN6 0BT, United Kingdom
CWI 8208 V1
Loading...