Collingwood Lighting H2 LITE 500 CSW Installation Instructions

Page 1
H2 LITE 500 CSW
INSTALLATION INSTRUCTIONS / MONTAGEANLEITUNG
Patent information: | Patentinformation: collingwoodlighting.com/patent
Cut ceiling hole Deckenhohlraum öffnen
Insulation* | Isolierung
Ø64-72mm
*The product is insulation coverable.
Connect to mains Mit Stromnetz verbinden
EN DE
• Isolate the mains supply, prior to wiring.
• This unit must be wired by a qualified electrician or suitable competent person.
• Rated voltage 220-240V AC.
• Input current 0.03A.
• H2 LITE 500 CSW is not compatible with auto detect dimming functions. Auto detect must be switched off or disabled.
• Collingwood Lighting advises the following maximum loads to assist functionality of the dimming driver when used with suitable standard mains wall dimmers.
- 5 x units on a 250W dimmer
- 10 x units on a 500W dimmer
- 15 x units on a 1000W dimmer
• For better dimming performance, use dimmers which have been designed for electronic LED drivers, e.g.
• Collingwood DM298 - Min 1, Max 10 units.
• Varilight V COM 220W – Min 3, max 26 units.
• Legrand Mosaic 078407 - Min 1, max 10 units.
• Legrand Celiane 067083 - Min 1, max 10 units.
• If in doubt, contact the dimmer manufacturer for advice. Quote the input power of 6.4W, and inrush current of 1.1A 0.02ms.
• The above figures are for guidance only. All installations must comply with the appropriate standards.
• Input power 6.4W / Power factor 0.9
• Suitable for 30, 60, and 90 minute fire-rated ceilings.
• The light source of this luminaire is not replaceable. When the light source reaches it’s end of life the whole luminaire shall be replaced.
See overleaf for colour temperature selection and reset.
Install centrally into ceiling hole Installieren Sie den Strahler in die
Mitte des Deckenausschnitts
220-240V AC 50/60Hz
IP20
IP65
Montagedaten
• Trennen Sie vor dem Anschluss die Stromversorgung.
• Dieses Gerät darf nur von einer Elektrofachkraft oder einer entsprechend qualifizierten Person angeschlossen werden.
• Nennspannungsbereich 220-240 VAC.
• Eingangsstrom 0,03A.
• H2 LITE 500 CSW ist nicht mit automatischer Dimmung-Funktionen kompatibel. Die automatische Dimmung-Funktion muss ausgeschaltet oder deaktiviert werden.
• Collingwood Lighting empfiehlt die folgenden maximalen Belastungen, um die Funktionalität des Treibers beim Dimmen mit geeigneten, handelsüblichen Netzspannungs-Wanddimmern zu gewährleisten: – 5 Leuchten an einem 250W Dimmer – 10 Leuchten an einem 500W Dimmer – 15 Leuchten an einem 1000W Dimmer
• Für bessere Dimmleistung benutzen Sie Dimmer, die für elektronische LED-Treiber konzipiert wurden, z.B.:
• Varilight V COM 220W - Min 3, max. 26 Strahler.
• Legrand Mosaic 078407 - Min 1, max. 10 Strahler.
• Legrand Celiane 067083 - Min 1, max. 10 Strahler.
• Im Zweifelsfall wenden Sie sich an den Hersteller des Dimmers. Nennen Sie die Eingangsleistung des Strahlers mit 6,4W und den Einschaltstrom mit 1,1A 0,02ms.
• Die oben genannten Werte sind Richtwerte. Alle Anlagen müssen den entsprechenden Normen entsprechen.
• Eingangsleistung 6,4W / Leistungsfaktor 0,9
• Geeignet für Brandschutzdecken F30, F60 und F90.
• Die Lichtquelle dieser Leuchte ist nicht austauschbar. Wenn die Lichtquelle nicht mehr funktionsfähig ist, muss die komplette Leuchte ersetzt werden.
Auf der Rückseite finden Sie Informationen zum Zurücksetzen der Farbtemperatur.
Cord grip adaptor / Wired connector Die Zugentlastungsklemme / Verkabelte
Anschlussdose
2 x 6242Y 3 x 1.5mm
or | oder
2 x R02V 3 x 1.5mm
EN
t +44 (0) 1604 495 151 f +44 (0) 1604 495 095 e sales@collingwoodgroup.com w collingwoodlighting.com
DE
t +49 (0)89 411123 777 f +49 (0)89 411123 778 e verkauf@collingwoodgroup.com w collingwoodlighting.com
Collingwood Lighting, Brooklands House, Sywell Aerodrome, Sywell, Northampton NN6 0BT, United Kingdom
1 2
Insert pivot legs into location holes Zapfen in die vorgesehenen Öffnungen
schieben
1
Push firmly to snap shut Fest zudrücken, bis Klappe einrastet
Push here | Hier drücken
2
HLI 1161 V2
To open connector, lever apart Zum Öffnen der Anschlussdose Deckel
hochklappen
Lever in here | Hier hochklappen
Page 2
H2 LITE 500 CSW
INSTALLATION INSTRUCTIONS / MONTAGEANLEITUNG
Patent information: | Patentinformation: collingwoodlighting.com/patent
EN DE
LED colour temperature selection
• Options are 3000K, 4000K, 6500K.
• If using a dimmer, turn up to full brightness.
• To change LED colour, turn LED units on, then turn mains switch off / on once very quickly (less than 1 second).
Reset
• In the unlikely event that the colour temperature becomes mixed, e.g. some units are 3000K and some are 4000K, they can be reset.
• Switch on LED units. If using a dimmer, turn up to full brightness. Wait approx. 10 seconds then turn the mains switch off/on quickly seven times. Note: Allow the LEDs to start to illuminate each time before switching off. i.e. off, on, LEDs illuminate, off, on, LEDs illuminate etc.
• After switching off/on seven times, the LEDs will flash and all will reset at 3000K.
• Select required colour temperature.
Dimmers
• Some dimmers are programmed by a series of switch on switch off actions. When doing this, the LED’s may change colour.
• Ignore this and complete the dimmer programming. When finished, select the LED colour temperature.
LED Farbtemperatur Auswahl
• Optionen sind 3000K, 4000K, 6500K.
• Falls Sie einen Dimmer verwenden, stellen Sie ihn auf die höchste Stufe.
• Um die LED-Farbe zu ändern, schalten Sie die LED-Einheiten ein und schalten Sie den Netzschalter dann sehr schnell aus (weniger als 1 Sekunde).
Zurücksetzung
• In dem unwahrscheinlichen Fall, dass die Farbtemperatur gemischt wird, z.B. Einige Einheiten sind 3000K und einige 4000K, können diese zurückgesetzt werden.
• Schalten Sie die LED Einheit ein. Wenn Sie einen Dimmer verwenden, stellen Sie die volle Helligkeit ein. Warten Sie circa. 10 Sekunden und schalten Sie den Netzschalter siebenmal aus und an.
• Hinweis: Lassen Sie die LED vor jedem Ausschalten aufleuchten, z.B. aus, an, LEDs leuchten, aus, an LEDs leuchten usw.
• Nach siebenmaligen ein-/ausschalten, LEDs werden blinken und auf 3000K zurückgesetzt.
• Wählen Sie die gewünschte Farbtemperatur aus.
Dimmer
• Einige Dimmer werden durch eine Reihe von Ein- / Ausschaltvorgängen programmiert. Wenn dies geschieht, können die LEDs ihre Farbe ändern.
• Ignorieren Sie dies und schließen die Dimmerprogrammierung ab. Wenn Sie fertig sind, wählen Sie die LED-Farbtemperatur.
EN
t +44 (0) 1604 495 151 f +44 (0) 1604 495 095 e sales@collingwoodgroup.com w collingwoodlighting.com
DE
t +49 (0)89 411123 777 f +49 (0)89 411123 778 e verkauf@collingwoodgroup.com w collingwoodlighting.com
Collingwood Lighting, Brooklands House, Sywell Aerodrome, Sywell, Northampton NN6 0BT, United Kingdom
HLI 1161 V2
Loading...