220-240V AC Mains 50-60Hz
DM298
L1 CL2
2-Way
Switch
L2
L1
COM
LED
UNIT
LED
UNIT
UP TO
MAX LED
LOAD =
100W
(10 LEDS
MAX)
DM298FP/DM298 GRID
Wiring instructions
INSTALLATION
DM298FP
• Isolate mains supply
• Use supplied plastic tool to remove the nut from the spindle of the dimmer.
• Fit the dimmer into the front plate, fit and tighten the spindle nut.
• Connect the dimmer to the mains supply, 220-240V AC, 50Hz.
See below for wiring examples.
• Secure the face plate to the back box.
WIRING EXAMPLES
1 Way
DM298GRID
• Isolate mains supply
• Refer to the grid assembly instructions below to fit the appropriate grid adaptor, and clip
the adaptor into the grid.
• Connect the dimmer to the mains supply, 220-240V AC, 50Hz. See below for wiring
examples.
• Secure the face plate to the grid plate.
2 Way with 2 way switch
UP TO
MAX LED
LOAD =
100W
(10 LEDS
MAX)
DM298
L1 CL2
L
N
220-240V AC Mains 50-60Hz
LED
UNIT
LED
UNIT
SET MINIMUM BRIGHTNESS
The minimum brightness level can be adjusted if desired.
• Start with dimmer OFF
• Rotate knob clockwise to MAXIMUM
• Switch dimmer ON
• Rotate knob anticlockwise to minimum brightness.
• Turn dimmer OFF, then back ON.
• Rotate knob clockwise to maximum.
• Turn dimmer OFF, then back ON.
• LEDs will flash twice. Dimmer is now in setting mode.
• Turn knob to desired minimum brightness.
• Turn dimmer OFF, then back ON. LED’s will flash once to confirm the new
setting is saved.
NOTE: If flickering is noticed at the minimum level, slightly increase the minimum
brightness setting.
The minimum brightness can be reset by repeating the above process.
LED
COM
2-Way
Switch
L2
L1
L
N
220-240V AC Mains 50-60Hz
DM298
L1 CL2
UNIT
Grid Plates with 2 or more dimmers must be de-rated to 70W per gang
Number of dimmer
switches per plate
Nominal plate size (mm) MAX Loading per plate
1 86 x 86 100W
2 86 x 86 140W
3 86 x 146 210W
4 86 x 146 280W
LED
UNIT
UP TO
MAX LED
LOAD =
100W
(10 LEDS
MAX)
(Max 10 LEDs per circuit)
GRID ASSEMBLY
1. Remove knob. 2. Choose the appropriate adaptor
2. to fit your
BG -
British
General
grid.
Crabtree DeltaHagerHamiltonSchneider
3. Fit the adaptor and secure with the ring.4. Replace knob and fit dimmer into grid plate
EN
t +44 (0) 1604 495 151 f +44 (0) 1604 495 095 e sales@collingwoodgroup.com w collingwoodlighting.com
Electric
MK Wandsworth
CWW 6093 V4