General Information .................................................................................................................................... 3
General Safety Information ....................................................................................................................... 3
Installation and Startup .............................................................................................................................. 8
Normal Operation ...................................................................................................................................... 10
Turning Your Circulator ON .................................................................................................................... 10
Main Operational Display........................................................................................................................ 10
Technical Information ............................................................................................................................... 21
Thank you for choosing the Cole-Parmer® Polystat® Standard Immersion Circulator. It is intended for the
precise temperature control of suitable liquids in a reservoir. Extremely easy to use and maintain, it
combines design innovation with highly intuitive operation to deliver convenient and versatile liquid
temperature control for a wide range of applications.
WARNING: Circulating Baths are not intended for directly controlling the temperature of foods,
pharmaceuticals, medicines, or other objects which may be ingested by or injected in humans or
animals. Any such objects must be isolated from contact with the bath fluid and bath surfaces.
Here are some of the features that make the Standard Immersion Circulator so user-friendly:
• Simple, intuitive operation
• Displays actual and set point temperature simultaneously
• Powerful pump, easy flow adjustment
• Attaches securely to both flat and rounded tank walls
• Converts any tank or vessel up to 28 liters into a reliable circulating bath
• Fully enclosed housing prevents direct contact with pump and heater, yet provides quick
access for inspection and cleaning
• Suitable for use with Class I non-flammable fluids per DIN 12876-1
It will take you very little time to get your new Standard Immersion Circulator installed and running, This
User Guide is designed to guide you quickly through the process. We recommend that you read it
thoroughly before you begin.
3
General Information
General Safety Information
When installed, operated, and maintained according to the directions in this manual and common safety
procedures, your Standard Immersion Circulator should provide safe and reliable liquid heating. Please
ensure that all individuals involved in the installation, operation, or maintenance of this unit read this
manual thoroughly prior to working with the unit.
This symbol alerts you to a wide range of potential dangers.
This symbol advises danger from electricity or electric shock.
This symbol indicates that a hot surface may be present.
/
This symbol marks information that is particularly important.
This symbol indicates alternating current.
These symbols on the Power Switch / Circuit Breaker indicate that they place the main power supply
ON / OFF.
This symbol on the Power Key indicates that it places the unit in a standby mode. It DOES NOT fully
disconnect the unit from the power supply.
This symbol indicates a protective conductor terminal.
Read all instructions pertaining to safety, set-up, and operation.
Proper operation is the user’s responsibility.
4
•
Safety Recommendations
To prevent injury to personnel and/or damage to property, always follow your workplace’s safety
procedures when operating this equipment. You should also comply with the following safety
recommendations:
WARNING:
• This Immersion Circulator is suitable only for use with Class I non-flammable fluids (per DIN
12876-1).
• Be aware of the chemical hazards that may be associated with the bath fluid used. Observe all
safety warnings for the fluids used as well as those contained in the material safety data sheet.
• Use only recommended bath fluids; see Technical Information in the rear of this manual for
recommendations.
Use only non-acid bath fluids.
WARNING:
• Always connect the power cord on this Circulator to a grounded (3-prong) power outlet. Make
certain that the outlet is the same voltage and frequency as your unit.
• Never operate the Circulator with a damaged power cord.
• Always turn the Circulator OFF and disconnect mains power before performing any maintenance
or service.
WARNING:
• Never operate the Circulator without bath fluid in the reservoir. Periodically check the reservoir to
ensure that the liquid depth is within acceptable levels. Always refill the reservoir using the same
bath fluid that is already in the reservoir. Bath oil must not contain any water contaminants and
should be preheated to the actual bath temperature before adding as there is an explosion hazard
at high temperatures.
• Turn electrical power to the unit OFF and remove Immersion Circulator from reservoir before
draining. Always drain all fluid from the reservoir before moving or lifting. Be sure to follow your
organization’s procedures and practices regarding the safe lifting and relocation of heavy objects.
WARNING:
• Always allow the bath fluid to cool to ambient temperature before draining.
• Always keep within the 85°C maximum operating temperature limit if using a polycarbonate open
bath tank
WARNING: It is the user’s responsibility to properly decontaminate the unit in the event hazardous
materials are spilled on exterior or interior surfaces. Consult manufacturer if there is any doubt
regarding the compatibility of decontamination or cleaning agents.
.
5
Regulatory Compliance and Testing
This equipment is compliant with the European Directive 2002/95/EC and its latest amendments on
Restrictions on Hazardous Substances (RoHS) and below the given limits of hazardous substances.
ETL Intertek (60 Hz units)
UL 61010-1 / CSA C22.2 No. 61010-1 — Safety Requirements for Measurement, Control, and
Laboratory Use; Part 1: General Requirements
UL 61010A-2-010 / CSA C22.2 No. 61010-2-010:04 — Safety Requirements for Measurement, Control,
and Laboratory Use; Part 2-010: Particular Requirements for Laboratory Equipment for the Heating of
Materials
UL 61010A-2-051 / CSA C22.2 No. 61010-2-051:04 — Safety Requirements for Measurement, Control,
and Laboratory Use; Part 2-051: Particular Requirements for Laboratory Equipment for the Mixing and
Stirring
Your Immersion Circulator is packed in a special carton. You should keep this carton, along with all
packing materials, until the unit has been installed and you are certain it is working properly.
CAUTION: Remove any loose packing material that may have fallen into the heater/pump housing
during shipping. Before powering up, check that nothing remains around the heater or circulator pump.
We recommend that you begin using your Immersion Circulator immediately to confirm proper operation,
since beyond one week you may be eligible for warranty repair only (rather than replacement). You’ll find
complete warranty information in the back of this manual.
In the unlikely event that the unit was damaged or does not operate properly, immediately contact the
transportation company, file a damage claim, and contact the company where your Immersion Circulator
was purchased.
Package Contents
The following items are included in the shipping carton:
• Standard Immersion Circulator
• Quick-Start Guide
• Resource Disk with Operator’s Manual
• Qualification Test Results
6
Backlit
Display
Up Arrow
Down Arrow
Menu
Button
Power
Button
Safety Thermostat
(under
Maximum
Liquid Level
Indicator
Front Flow
Adjuster
Mounting
Clamp
Rear Flow
Adjuster
Heater /Pump
ver
Power Cord
Actual Bath
Temperature
Temperature
Set Point
Heating
Circulating
Controls and Components
Button
Button
plate)
Access Co
Front ViewRear View
Main Display
7
Quick-Start
See Installation and Startup for additional information.
1
2
3
Attach Immersion Circulator
to reservoir
Fill reservoir with fluid
Connect power cord to
electrical outlet
4
5
6
Turn Immersion Circulator “ON”
Enter temperature set point
Set safety thermostat once the
unit reaches set point
Loading...