Magnifier position
Control panel
Figure 1 - Colony Counter controls
Receiver
plate
Printer
connector
Power
on/off
switch
Figure 2 - Colony Counter back panel
Sensitivity
adjustment
PC
connector
(USB)
IEC
Power
socket
Fuse
2
Background
adjustment
Dish adapters
Figure 3 - Underneath the Colony Counter
Colony Counter
Introduction
Thank you for purchasing this Cole-Parmer product. To get the best performance from the
equipment, and for your own safety, please read these instructions carefully before use.
Before discarding the packaging check that all parts are present and correct.
This equipment is designed to operate under the following conditions:-
❖ For indoor use only
❖ Use in a well ventilated area
❖ Ambient temperature range +5°C to +40°C (+41°F to +104°F)
❖ Altitude to 2000m (6500ft)
❖ Relative humidity not exceeding 80%
❖ Power supply fluctuation not exceeding 10% of nominal
❖ Overvoltage category II IEC60364-4-443
❖ Pollution degree 2 IEC664
❖ Use with a minimum distance all round of 200mm, (8 in.) from walls or other items
If the equipment is not used in the manner described in this manual and with accessories other than
those recommended by the manufacturer, the protection provided may be impaired.
Electrical Installation
THIS EQUIPMENT MUST BE GROUNDED
Before connection please ensure that the line supply corresponds to that shown on the
rating plate located on the base of the unit.
Power requirements:
Model:
14312-00 70W Universal 90-240V F3.15A (x2)
The Colony Counter is provided with a UK 3-pin and a “Schuko” 2-pin plug for 230v installations and
a NEMA 5-15 plug for 120v installations.
Should the cable not be suitable for connecting to the power supply, replace the plug with a suitable
alternative.
IT IS IMPORTANT THAT THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY A
QUALIFIED ELECTRICIAN
NOTE: Refer to the equipment rating plate to ensure that the plug and fusing are suitable for the
voltage and wattage stated.
The wires in the power cable (230V) are colored as follows:
BROWN - HOT/LIVE
BLUE - NEUTRAL
GREEN/YELLOW - EARTH
3
The wires in the power cable (120V) are colored as follows:
BLACK - HOT/LIVE
WHITE - NEUTRAL
GREEN - EARTH
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN
Should the power cable need replacing, a cable of 1mm
an IEC320 plug should be used.
The appropriate power cable should be connected BEFORE connection to the power supply.
2
of harmonized code H05W-F connected to
General Description
The Colony Counter consists of an illuminated receiver plate and a large LED display (see Fig. 1). The
pressure of marking a colony with a felt-tip pen registers a count by an audible bleep and advance on
a digital display. A built-in averaging facility allows multiple plates to be counted and then the average
colony count calculated.
A choice of light or black background is available and the pressure required to register a count can
be adjusted. The unit is supplied complete with one Wolffhuegel graticule, segmentation disc and
centering adapters for 50-90mm dishes. A printer and a magnifier for counting very small colonies are
available as accessories. Counting results may also be sent to a computer via USB.
Safety Advice
Users should be aware of the following safety advice:
❖ The unit should be carried using both hands with the fingers under the side edges.
❖ NEVER move or carry the unit with containers on the top or while still connected to the power
supply.
❖ In case of power interruption, a fault or mechanical failure, the unit will continue to operate on
removal of fault.
❖ DO NOT position the unit such that it is difficult to disconnect it from the power by removing the
power cable from the socket at the back.
Operation
Setting Up the Colony Counter
To select either the dark or white background, slide the panel, which can be found underneath the
unit (see Fig. 3), to the left or right until the background clicks home into place. To use a petri dish of
less than 90mm (3.5 in.) in diameter, select the appropriate adapter, which can also be found on the
underside of the unit (see Fig. 3) and place on the receiver plate.
The Colony Counter is provided with a pack of clear discs, designed to protect the receiver plate
from dust and scratches. Place a disc in the receiver plate. If this becomes damaged, remove and
replace with another. If the Wolffhuegel graticule or segmentation disc is required, place on top of the
clear protective disc on the receiver plate.
Position the unit on a firm level surface. The sensitivity control dial, located at the back of the unit (see
Fig. 2), can adjust the pressure required to register a count. Turning it clockwise will increase the
sensitivity, turning it counter-clockwise will decrease the sensitivity.
4