Cole-Parmer 04661-43, 04661-44, 04661-45, 04661-46, 04661-39 Instruction Manual

...
04661- 43 04661- 44 04661- 45 04661- 46
04661- 39 04661- 40
User manual
Magnetic Stirrer with Heating
Magnetic Stirrer
Stir Heat Timer
04661- 29 04661- 30
Stir Timer
04661- 41 04661- 42
Stir Heat
Contents
Safety instructions . . . .. . ... . .. . . .. . . .. . ... . .. . . .. . . .. . ... . .. . . .. . .
Maintenance and cleaning .. . ... . .. . . .. . . .. . ... . .. . . .. . . .. . ... . .. . . .. .
Warranty . . ... . ... ... . ... . ... . ... ... . ... . ... . ... . .. . ... . ... . ... . ..
Model:
Support rod installation
04661-43
04661-44
. .. . . .. . ... . .. . . .. . . .. . ... . ... . .. . . .. . . .. . ... .
04661-39
04661-40
04661-45
04661-46
04661-41
Switching on .. ... .. . .. . .. . .. . .. ... ... ... .. . .. . .. . .. . .. ... ... ... .. . .. . .. . .
Plate overview ... . ... . .... .. . . .. . ... . .. . . .. . . .. . ... . ... . .. . . .. . . .. .
Setting safety temperature .. .. . . .. . ... . .. . . .. . . .. . . .. . ... . .. . . .. . . .. . .
Setting heating temperature . . .. . . .. . .. . ... . .. . ... . .. . .. . . .. . .. . ... . .. .
Setting stirring speed ... . .. .. . . .. . ... . .. . . .. . . .. . ... . ... . .. . . .. . . .. . .
Reverseible / Intermittent stirri ng func tion ... .. .. . . .. . ... . .. . . .. . . .. . ... .
Setting the timer ... . ... .. .. . . .. . ... . .. . . .. . . .. . ... . ... . .. . . .. . . .. .
Locking function . . .. . . .. . ... . .. . . .. . . .. . ... . .. . . .. . . .. . ... . .. . . .. .
Switch off and data saving .. . ... . .. . . .. . . .. . ... . .. . . .. . . .. . ... . .. . . ..
Troublesh ooting guide . . .. . .. . . .. . .. . .. . ... . .. . .. . ... . .. . .. . .. . . .
Technical data . .. . ... . .. .. . . .. . ... . .. . . .. . . .. . ... . ... . .. . . .. . . .. . .
Model:
Switching on .. . ... . .. . . .. . . .. . ... . .. . . .. . . .. . ... . .. . . .. . ... . ... . .
04661-29
04661-30
Plate overview ... . .. . . .. . . .. . ... . ... . .. . . .. . . .. . ... . .. . . .. . ... . ...
Setting stirring speed and reverse mode . . .. . ... . .. . . .. . . .. . ... . .. . ... .
Setting the timer ... . .. . . .. . . .. . ... . .. . . .. . . .. . ... . .. . . .. . . .. . ... . .
Switch off and data saving .. . ... . .. . . .. . . .. . ... . .. . . .. . . .. . ... . .. . . ..
Troubleshooting gu ide .. . . .. . ... . .. . . .. . . .. . ... . .. . . .. . . .. . ... . .. . . .
Technical data ... . .. . . .. . . .. . ... . .. . . .. . . .. . ... . .. . . .. . . .. . ... . ...
1 2-
04661-42
13 15-
10 11 12 12
16
17 18 19 20 20 21 22
3 3
4 5 6 7 8 9
Standard accessories
User man ual
Magnetic Stirrer with Heating
04661-43 04661-44 04661-45 04661-46
04661-39 04661-40 04661-41
User manual ×1
04661-42
Stirring bar ×1
Power
Magnetic Stirrer
Stir Heat Timer
04661-29 04661-30
Stir Timer
Stir Heat
line ×1
Safety instructions
·When operating the magnetic stirrer, please follow the safety instructions, the accident prevention regulations, and pay attention to your occupational health.
· Notice: Effects of magnetic field should be taken into account(e.g.data storage, cardiac pacemakers...)
· Risk of burns! The heating plate can reach a high temperature of 280 °C when the stirrer is working. Please exercise caution when
touching the outer housing and the heating plate. Pay attention to the residual heat even after the instrument is shut down.
!
· Ensure that the power cord does not make contact with the heating plate.
· Wear appropriate protective equipments when operating.
!
Otherwise there may have risks from:
- Splashing of medium
- Ejection of stirrer bar
- Release of toxic or flammable gases
·Place the instrument on a stable, clean, anti-slip, dry and fireproof surface.
·Ensure the base of instrument is clean and intact.
·Check and ensure the instrument and accessories remain intact before each use. Do not use damaged components.
·Slowdown the speed if
- The medium splashes out of container in high speed
- The container shifts on the plate
· Beware of hazards due to:
!
- Flammable materials
- Low-boiling flammable medium
- Improper container size
- - Overflows of the medium
The container is in an unsafe condition
• The instrument may be heated up under normal use.
• The medium in the container can still be heated up due to high speeds rotation of the magnetic stirrer bar, even if the heating function is not on.
• Process pathogenic materials only in airtight container within a suitable fume hood. Do not operate the instrument in explosive atmospheres, with hazardous substances or under water.
!
21211
Safety instructions
• Only use medium that will not react dangerously with the energy generated through processing or through other ways e.g. light irradiation.
• Safe operation is only guaranteed with the accessories described in the ‘Optional accessories’ section.
• Please use the accessories listed on the manual in accordance with the operating instructions.
• Ensure that the external temperature sensor is immersed in the medium when connected to thermometer(Pt1000s).
• Accessories must be securely installed and firmly attached to the instrument and the centre of gravity of the assembly must lie within the surface on which it is set up.
• Always disconnect power before installing accessories.
• The instrument can only be disconnected from the power supply by pulling out the power plug.
Caution: Do not spill corrosive liquids on the instrument! Do not use the instrument under water!
!
• Caution: High voltageThe appliance should be opened only by professionally trained maintenance and repair personnel.
!
• The mains voltage must be in accordance with the voltage marked on the nameplate
• Unplug the instrument from the electric outlet if it will be unused for a long period of time.
• Do not cover the device with cloth or plastic film, or the instrument will be overheat.
• Keep the instrument and accessories from pressing and colliding.
• The minimum distance between the instrument and above should be 800mm.
• Ensure the distance between the instruments and the distances between the instrument and the surrounding walls is at lease 100mm.
>10 0mm
>10 0mm >10 0mm
2
Maintenance and cleaning
• Keep the surface of the plate clean and intact.
• Unplug the power line before cleaning.
• Minimize exposure to moisture when cleaning instrument.
• Wear protective gloves when cleaning.
We only recommend using the cleaning methods listed below, using alternate cleaning methods may cause damage to the instrument.
Suggested cleaning methods:
Dyes------------------------Isopropyl alcohol Construction materials------Water containing active agent / isopropyl alcohol Cosmetics-------------------Water containing active agent / isopropyl alcohol Foodstuffs ------------------Water containing active agent Fuels------------------------Water containing active agent
Warranty
• This instrument is warranted for a period of 24 months from the date of invoice. For claims under the warranty please contact Cole­ Parmer . After receiving confirmation from our warranty department, you will be liable for freight costs.
• The warranty does not cover normal wear and tear of parts or accessories, nor does it apply to improper use, abnormal operation or insufficient maintenance which is not in accordance with the instructions in this user manual.
• Make sure the instrument is clean and free from any materials that may harm people before sending for repair.
• Please send the instrument back to Cole-Parmer in its original packaging. If you couldn’t find the original packaging, ensure to use suitable packaging to protect the instrument during transportation.
21213
Support rod installation
Model:
04661-43
04661-44
04661-39
04661-40
04661-45
04661-46
04661-41
If using external temperature sensor to measure temperature of the medium, please install support rod, horizontal head clamp, horizontal holding rod and external temperature sensor.
1
Remove the white protective cap of the tapped hole
2
Remove the protective cap from support rod
3
Screw the support rod into the tapped hole, until the end stop is reached
4
Using a wrench to tighten the nut on the support rod
Install horizontal head clamp and horizontal holding rod as illustrated
5
Install external temperature sensor
6
04661-42
Support rod
Screw nut
Support rod
Pt1000s Slotted hole
Horizontal holding rod
Horizontal head clamp
Sensor interf ace
Attentio n!
When plug in the sensor, make sure the arro w poi nt up ward.
Pt1000s temperature sensor
4
Switching on
Model:
04661-43
04661-44
04661-39
04661-40
04661-45
04661-46
04661-41
04661-42
Preparation before start up
C
heck that the power voltage is in accordance with the voltage marked on the nameplate and the electric outlet is well grounded.
1
The instrument may be damaged and there may be security problem if someone does not strictly follow the above instruction. The instrument should be operated under appropriate temperature and humidity according to the technical parameters in this manual.
2
Set the power switch on the back of the device to the “O” (Power off) position.
3
Connect the power line.
4
If using external temperature sensor to measure temperature of the medium, please plug the sensor connector into the sensor interface on the back of the instrument.
21215
Power soc ket
Power swi tch
Mode
Supply voltage
Power frequency
Mode
Supply voltage
Power frequency
04661-39
04661-43
04661-44
04661-40
115V±10%
~50/60Hz
220V±10%
~50/60Hz
04661-45
04661-46
04661-41
04661-42
Switching on
1
Set the power switch to the | (Power on) position and the “Standby” indicator will be lit and the system enters into standby status.
2
Press (power on / off) to activate the instrument, and then the standby indicator will go off.
Plate overview
Model:
04661-43
04661-44
04661-39
04661-40
04661-45
04661-46
04661-41
04661-42
Rod tapped hole
Stirring bar
Storage socket
LCD dis pla y
Model:
04661-39
5 1
6
7
8
9
Item De sig nation
Setting temperature
6
External sensor icon
10
Real-time stirring speed
15
Timing icon(Dynamical)
Touch wheel
LCD display
Switch
Start / Stop
Function key
Power on/off
Hot warning indicator
04661-40
34
10
Plate safety temperature icon Real-time temperature
7
Heating plate icon
11
Stir setting speed
04661-41
2
04661-42
11
321
8
12
Stirring icon(Dynamical)
Stir timing icon
How to use the touch wheel
Touch and move your finger around the “Touch wheel” clockwise+ / counterclockwise- (follow the direction of the arrow) to adjust the setting of different configuration with the adjustable increment. The faster the movement of the finger the larger the adjustment of the setting parameter and vice versa so that one can rapidly adjust to the desired configuration zone and then slow down the finger movement to accurate position.
Model:
5 1
6
7
8
9
04661-43
11
4
Key-lock icon
9
Reversible/Int ermittent mode icon
13
Heat timing icon
04661-44
34
04661-45
12
5
Heating icon(Dynamical)
14
Timer setting time
2
13
04661-46
14 15
6
Loading...
+ 19 hidden pages