Coleman Cable 823427 User Manual

Royal® 300V SJOOW
Construction Parameters:
CONDUCTOR: 18 AWG - 10 AWG Class K stranded bare copper per ASTM B-174 INSULATION: EPDM
JACKET: CPE COLOR: Black (Other colors available upon request) PRINT LEGEND: SOUTHWIRE® ROYAL® (5 CROWN LOGO) CORD X/C XX AWG (X.XXmm2) SJOOW E46194 (UL) 300V -40C TO 90C - -
CSA LL39753 SJOOW 300V -40C TO 90C FT2 WATER RESISTANT
INDENT LEGEND: P-07-KA070018-1-MSHA
PHYSICAL PROPERTIES:
TEMPERATURE RANGE:
-40°C to 90°C
WATER RESISTANT: Yes
ELECTRICAL PROPERTIES:
VOLTAGE RATING: 300V rms, Max
Industry Approvals:
o UL Standard 62 o CSA Standard C22.2 No. 49 o NEC Article 501.140 Class I Div. 2 o NEC Article 400 o Federal Spec JC580 o Passes CSA FT2 Flame Test o MSHA o EPA 40 CFR, Part 26, Subpart C, heavy metals per Table 1, TCLP method
Part No.
Nom. DCR Color
Number Cond.
Inches mm Inches mm Lb./kft. kg/km Ω/1M' Code
823225 18 2 16/30 0.030 0.76 0.285 7.24 0.280" - 0.315" 37 55
10 6.59 Black, White
823325 18 3 16/30 0.030 0.76 0.310 7.87 0.300" - 0.335" 49 73
10 6.59 Black, White, Green
823425 18 4 16/30 0.030 0.76 0.330 8.38 0.325" - 0.365" 59 88
7 6.59 Black, White, Red, Green
823226 16 2 26/30 0.030 0.76 0.310 7.87 0.305" - 0.340" 46 68
13 4.05 Black, White
823326 16 3 26/30 0.030 0.76 0.330 8.38 0.325" - 0.360" 59 88
13 4.05 Black, White, Green
823426 16 4 26/30 0.030 0.76 0.357 9.07 0.350" - 0.395" 73 109
10 4.05 Black, White, Red, Green
823227 14 2 41/30 0.030 0.76 0.340 8.64 0.335" - 0.375" 60 89
18 2.55 Black, White
823327 14 3 41/30 0.030 0.76 0.365 9.27 0.360" - 0.395" 79 118
18 2.55 Black, White, Green
823427 14 4 41/30 0.030 0.76 0.395 10.03 0.390" - 0.435" 98 146
15 2.55 Black, White, Red, Green
823228 12 2 65/30 0.030 0.76 0.410 10.41 0.405" - 0.455" 90 134
25 1.61 Black, White
823328 12 3 65/30 0.030 0.76 0.430 10.92 0.425" - 0.475" 116 173
25 1.61 Black, White, Green
823428 12 4 65/30 0.030 0.76 0.470 11.94 0.465" - 0.520" 150 223
20 1.61 Black, White, Red, Green
823229 10 2 104/30 0.045 1.14 0.545 13.84 0.540" - 0.605" 155 231
30 0.98 Black, White
823329 10 3 104/30 0.045 1.14 0.569 14.45 0.565" - 0.635" 200 298
30 0.98 Black, White, Green
823429 10 4 104/30 0.045 1.14 0.635 16.13 0.625" - 0.700" 257 382
25 0.98 Black, White, Red, Green
* Ampacity based on NEC Table 400.5(A) and CEC Table 12.
This product complies with European Directive 2011/65/EU (RoHS-2) The customer will accept all factory lengths and +/- 10 percent of total order requested. The jacket is sequentially footprinted from 2 to the footage designated by the put-up code.
Specification Issue Date: June 23, 2014
Net Weight
UL 62
O.D. Range
PRODUCT DATA SHEET
Controlled Document - Engineering Drive
1530 Shields Drive
Waukegan, IL 60085
Toll-Free (800) 323-9355
Fax: (847) 689-1192
The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Southwire's control all product data presented is for informational purposes only and does not create a binding obligation or liability on Southwire or confer any rights on any customer. The sale of products(s) is conditioned upon acceptance of a purchase order subject to Southwire disclaims all liability in connection with the use of information contained herein or otherwise.
This specification is proprietary intellectual property of Southwire. Any information contained herein shall not be disclosed to any party without written consent of Southwire.
Insulation Wall, Nom.
O.D., Nom.
Amps*
Note: All dimensions & weights are nominal subject to industry standards and tolerances unless otherwise noted.
Stranding
AWG
1-800-323-9355 (Phone) 1-847-689-1192 (Fax)
823225_thru_823429_SJOOW Specs
Designed By: GJK
© 2015 Southwire