Coleman 445349-CTG-B-0409, TMLX, TM8X User Manual

TECHNICAL GUIDE
EFFICIENCY RATING CERTIFIED
ISO 9001
Certified Quality
Management System
GAS-FIRED RESIDENTIAL SINGLE STAGE MULTI-POSITION GAS FURNACES STANDARD &Low NOx MODELS
MODELS: TM8X / TMLX
Due to continuous product improvement, specific a t io ns are subject to change without notice.
Visit us on the web at www.york.com Additional rating information can be found at
www.ahridirectory.org
WARRANTY
20-year limited warranty on the heat exchanger. 10-year heat exchanger warranty on commercial applications. Standard 5-year limited Parts warranty.
Extended 10-year limited parts warranty when product is regis­tered online within 90 days of purchase for replacement or clos­ing for new home construction.
445349-CTG-B-0409
DESCRIPTION
These compact units employ induced combustion, reliable hot surface ignition and high heat transferalumin ized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications.
These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation.
These units are Category I listed and may be common vented with another gas appliance as allowed by the National Fuel Gas Code.
FEATURES
Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
Low unit amp requirement for easy replacement application.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.
100% shut off main gas valve for extra safety.
5 speed direct drive, X13 style high efficiency DC motor.
24V, 40 VA control transformer and blower relay supplied for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch.
Solid removable bottom panel allows easy conversion.
Low NOx models have been designed to meet specific code requirements.
Airflow leakage less than 1% of total airflow at ductblaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and removal of blower.
External air filters used for maximum flexibility in meeting customers IAQ needs.
Venting applications - may be installed as a common vent with other gas-fired appliances or use a masonry chimney.
1/4 turn knobs provided for easy door removal.
High-efficiency blower motor for lower electrical power usage and improved A/C SEER ratings.
Insulated blower compartment for thermal and acoustic performance.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
445349-CTG-B-0409
LEFT SIDE
RIGHT SIDE
.5”
.5”
RETURN END
B
24.25”
29.5”
28.5”
Electrical Entry
Gas Pipe Entry
Thermostat Wiring
FRONT
14”
1”
1.5”
23”
SUPPLY END
C
24.38”
20”
.5”
B
Gas Pipe Entry
Thermostat Wiring
33”
A
.5”
Electrical Entry
Vent Connection Outlet
Vent Connection Outlet
4” Diameter
Outlet
Vent Connection
Cabinet and Duct Dimensions
Approximate
Operating Weights
Models
Nominal
CFM (m
3
/min)
Cabinet
Size
Cabinet Dimensions (Inches)
ABCLbs
TM(8,L)X060A12MP11 1200 A 14 1/2 13 3/8 10.3 94 TM(8,L)X080B12MP11 1200 B 17 1/2 16 3/8 11.8 103 TM(8,L)X080C16MP11 1600 C 21 19 7/8 13.6 114 TM(8,L)X100C16MP11 1600 C 21 19 7/8 13.6 118 TM(8,L)X100C20MP11 2000 C 21 19 7/8 13.6 122 TM(8,L)X120C20MP11 2000 C 21 19 7/8 15.8 129
Ratings & Physical / Electrical Data
Models
Input Output
AFUE
Air Temp.
Rise
MBH MBH °F °F HP Amps TM(8,L)X060A12MP11 60 48 80.0 30-60 160 1/2 6.8 11 x 8 15 9.3 14 TM(8,L)X080B12MP11 80 64 80.0 35-65 165 1/2 6.8 11 x 8 15 9.3 14 TM(8,L)X080C16MP11 80 64 80.0 25-55 155 1/2 6.8 11 x 10 15 9.3 14 TM(8,L)X100C16MP11 100 80 80.0 35-65 165 1/2 6.8 11 x 10 15 9.3 14 TM(8,L)X100C20MP11 100 80 80.0 25-55 155 3/4 8.4 11 x 11 15 10.9 14 TM(8,L)X120C20MP11 120 96 80.0 35-65 165 3/4 8.4 11 x 11 15 10.9 14
HORIZONTAL SIDEWALL VENTING
Nominal external static pressure is 0.50” w.c. at f urnace outlet ahead of cooling coils. Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
For applications where vertical venting is not possible, the only approved method of horizontal venting is the use of an auxiliary power vent. Auxilary power venters must be approved by CSA, UL, or other recognized safety agencies. Follow all application and installation details provided by the manufacturer of the power vent.
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Perfor­mance” table listed above represents blower performance WITHOUT filters.
2 Johnson Controls Unitary Products
Max. Outlet
Air Temp
Blower
Blower
Size
All applications of these furnaces require the use of field installed air filters. All filter media and mounting hardware or provisions must be field installed external to the furnace cabi­net. DO NOT attempt to install any filters inside the furnace.
Max
Over-Current
Protect
Total Unit
Amps
Min. wire Size
(awg) @ 75 ft
one way
NOTE: Single side return above 1800 CFM is app roved as
long as the filter velocity does not exceed filter manufac­turer’s recommendation and a transition is used to allow use of a 20x25 filter.
Loading...
+ 2 hidden pages