95.0% AFUE SINGLE STAGE ECM
RESIDENTIAL GAS FURNACES
MULTI-POSITION
MODELS: TM9E
NATURAL GAS
40 - 120 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at
www.upgnet.com and www.colemanac.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY
A 20-year limited warranty on heat exchangers in residential
applications.
A 10-year warranty on the heat exchanger in commercial
applications.
Standard 5-year limited Parts warranty.
Extended lifetime heat exchanger and 10-year limited
parts warranty when product is registered online within
90 days of purchase for replacement or closing fo r new
home construction.
See Limited Warranty certificate in Users Information Manual for details.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
1104559-CTG-B-0714
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for downflow applications.
These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are
also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic combustion air and vent piping.
FEATURES
•Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
•Compact, easy to install, ideal height 33" tall cabinet.
•Blower-off delay for cooling SEER improvement.
•Easy access to controls to connect power/control wiring.
•Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable operation.
•Low unit amp requirement for easy replacement application.
•All models are convertable to use propane (LP) gas.
•Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
•100% shut off main gas valve for extra safety.
•5 speed, direct drive Standard ECM style high efficiency DC
motor.
•24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local code s.
The furnace shall be installed so that the electrical components are protected from water.
2Johnson Controls Unitary Products
Nominal
Airflow
AFUE
MBHCFM%°F°FHPAmps
Air Temp.
Rise
Max. Outlet
Air Temp
Blower
Blower
Over-Current
Size
Max
Protect
Total Unit
Amps
Min. wire Size
(awg) @ 75 ft
one way
Page 3
1104559-CTG-B-0714
NOTICE
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Performance” table shown represents blower performance WITHOUT
filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace.
Single side return above 1800 CFM is approved as long as
the filter velocity does not exceed filter manufacturer ’s recommendation and a transition is used to allow use on a
20x25 filter.
Recommended Filter Sizes (High velocity 600 FPM)
CFM
1000A16 x 2514 x 25
1200B16 x 2516 x 25
1600C16 x 2520 x 25
2000C(2) 16 x 2520 x 25
2000D(2) 16 x 2522 x 25
NOTES:
1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.
1.For combustible floors only when used with special sub-base.
* - 24" clearance in front and 18" on side recommended for service access.
All furnaces approved for alcove and attic installation.
UpflowDownflowHorizontal
1
Combustible
Combustible
ACCESSORIES
Propane (LP) Conversion Kit - This accessory conversion kit
may be used to convert natural gas (N) units for propane (LP)
operation.
S1-1NP0347 - All Models
Concentric Vent Termination - For use through rooftop, sidewall. Allows combustion air to enter and exhaust to exit through
single common hole. Eliminates unslightly elbows for a cleaner
installation.
Sidewall Vent Termination Kit - For use on sidewall, two-pipe
installations only. Provide a more attractive termination for locations where the terminal is visable on the side of the home.
S1-1HT0901 (3")
S1-1HT0902 (2")
Condensate Neutralizer Kit - Neutralizer cartridge has a 1/2"
plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also available from the Source 1 Parts
(P/N 026-30228-000).
1NK0301
Side Return Filter Racks -
S1-1SR0200 - All Models
S1-1SR0402 - All Models
Bottom Return Filter Racks - 1BR05xx series are galvanized
steel filter racks. 1BR06xx are pre-painted steel filter racks to
match the appearance of the furnace cabinet.
S1-1BR0514 or 1BR0614 - For 14-1/2” cabinets
S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets
S1-1BR0521 or 1BR0621 - For 21” cabinets
S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets
Combustible Floor Base Kit - For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential
overheating situations.tible floor base kit provides access for
combustible airflow.
S1-1CB0514 - For 14-1/2” cabinets
S1-1CB0517 - For 17-1/2” cabinets
S1-1CB0521 - For 21” cabinets
S1-1CB0524 - For 24-1/2” cabinets
High Altitude Pressure Switches - For installation where the
altitude is less than 5,000 feet it is not required that the pressure switch be changed. For altitudes above 5,000 feet, see kits
below.
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.
Johnson Controls Unitary Products3
Page 4
Blower Performance CFM - Any Position (without filter)
ModelsSpeed
0.10.20.30.40.50.60.70.80.91.0
High 129012601220116011001040960840750660
Medium High 11701140111010701040990930820730650
TM9E040A12MP11
TM9E060B12MP11
TM9E080B12MP11
TM9E080C16MP11
TM9E100C16MP11
TM9E100C20MP11
TM9E120D20MP11
NOTES:
1. Airflow expressed in standard cubic feet per minute (SCFM).
2. Motor voltage at 115 V.
Medium990980940900860830790730680630
Medium Low 900880850810770730670630600560
Low 730710690650620590540510480450
High 1402137413541328129912621222116711071036
Medium High 125212331203118211501125109510641031980
Medium1076105910291007973946908883843800
Medium Low 988967936903875838806765737685
Low 798769727695650619574517485443
High 1445142313971365133913111283125012041140
Medium High 1282126612321211118211571128109710691013
Medium1098108410591027998967939910879822
Medium Low 1012993953930894851828773752692
Low 865810763730689628594520496448
High 1713168216431600155815191480143613851333
Medium High 1554151914851439140413681327128011761130
Medium138013511302126312241171112810851030943
Medium Low 1177114210831050988922890819798687
Low 951841650588457418355227203N / A
High 1734169416501611157015361485143813921335
Medium High 1568153714921453141413731327127912301118
Medium14201380133212941249119611521100981938
Medium 12181169112410671015965894845754679
Low 979846647580464427345220195N / A
High 2143210220652028198919441892182517331625
Medium High 1788174917181672162915871541150014471355
Medium1575153915001456141013631305124610951030
Medium Low 1372132512761225117011111044972884812
Low 1031921810728660615518474391355
High 2214217321322086203619941952190718491777
Medium High 1841179917491699165916111567152014711372