Due to continuous product improvement, specifications are
subject to change without notice.
Visit us on the web at
www.upgnet.com and www.colemanac.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY*
Standard 5-years limited parts warranty.
Standard 10-years limited compressor warranty.
Extended 10-years limited parts warranty when product is
registered online within 90 days of purchase for replacement
or closing for new home construction.
*Does not apply to R-22 models, 3-Phase models, or internet sales.
See Limited Warranty certificate in User's Information Manual for details.
®
700700-CTG-A-0312
DESCRIPTION
The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with accessories and documents to serve specific functions.
FEATURES
• Small Footprint - Extremely lightweight with a compact foot-
print, it is a perfect fit for any application.
• Quality Condenser Coils - The coil is constru cted of aluminum microchannel tubing and enhanced aluminum fins for
reduced size and increased efficiency.
• Coil Protection - Coils are protected from damage by
a sturdy polymer mesh and a coated steel wire coil guard.
®
• Optional Factory E-Coat - Available ElectroFin
on select models.
• Protected Compressor - Compressors are protected internally by a high pressure relief valve and a temperature sensor, and externally by the system high pressure switch. A
factory installed liquid line filter-drier further protects the compressor against moisture and debris.
• Durable Finish - The cabinet is made of pre-painted steel.
The pre-treated galvanized steel provides a better paint-tosteel bond, which resists corrosion and rust creep. Special
primer formulas and matted-textured finish insure less fading
when exposed to sunlight.
• Lower Installed Cost - Installation time and costs are
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
• Top Discharge - The warm air from the top mounted fan is
blown up, away from the structure and any landscaping. This
allows compact location on multi-unit applications.
• Competitive Sound Levels - The upward air flow carries the
normal operating noise away from the living area. The rigid
top panel effectively isolates any motor sound. Isolator
mounted compressor and the condenser coil muffle the normal fan motor and compressor operating sounds.
• Low Maintenance - Long life, permanently lubricated motorbearings need no annual servicing.
• Easy Service Access - Fully exposed refrigerant connections and a single panel covering the electrical controls make
for easy servicing of the unit.
• Secured Service Valves - Secured, re-usable service
valves are provided on both the liquid and vapor swe at connections for ease of evacuating and charging.
• Agency Listed - Safety certified by CSA to UL 1995 / CSA
22.2. Performance certified to ANSI/AHRI Standard 210/240
in accordance with the Unitary Small Equipment certification
program.
coated coil
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
700700-CTG-A-0312
B
A
C
Physical and Electrical Data
MODEL
TCGF18
S41S3(E)
Unit Supply Voltage208-230V, 1 60Hz
Normal Voltage Range
Models with “E” on the end of the model number have an ElectroFin® coating on the outdoor coil.
1. Rated in accordance with ANSI/AHRI Standard 110-2002, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or
subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
TCGF24
S41S3(E)
TCGF30
S41S3(E)
TCGF36
S41S3(E)
187 to 252
TCGF42
S41S3(E)
TCGF48
S41S3(E)
TCGF60
S41S3(E)
All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.
FC/MC/PC60–––24161613
FC/MC62–––29212118
FC64–––39302926
HD2414––––––
HD36191916––––
HD48–4540342625–
HD60––––222218
UC182––––––
UC48––––11––
UC60–––2416––
Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product. For approved coil
only matches, please see the “COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils” table.
FOOTNOTES:
1. For applications requiring a TXV use S1-1TVM*** series kit.
2. A TXV kit must be used with these indoor units to obtain system performance.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit S1-2FD06700224.
4. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
5. Refer to Technical Guide for actual system performan ce for specif ied system matches.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit, the smallest matched indoor unit, and 15 feet of interconnecting line tubing.
2. Verify the TXV or orifice and additional charge required for specific matched indoor unit in the system using the above table.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For indoor matches requiring additional charge, the refrigerant needs to be weighed in for specific matched indoor unit and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + charge adder for matched indoor unit +
charge adder for line set.
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI /AHRI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.
1. MC coils available with a factory installed horizontal dr ain pan. See price pages for specific model number.
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
COOLING
NET MBH
SEEREER
8Johnson Controls Unitary Products
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
TOTALSENS.
700700-CTG-A-0312
1
SEER
EER
Johnson Controls Unitary Products9
700700-CTG-A-0312
COOLING CAP ACITY - With High Efficiency Motor Furnaces