This fan coil line offers the ultimate in application flexibility. This
unit may be used for upflow, downflow, horizontal right, or
horizontal left applications.
All JCI Unitary Products air handlers and coils can use a TXV to
provide our customers with the optimum performance and
refrigerant control. Single piece air handlers are available with
“Flex-coils” (without a factory installed metering device). For
added flexibility, an R-22 or R-410A TXV or piston must be field
installed to meet the requirement of the desired refrigerant.
Some coil models available with factory installed TXV.
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: MP - 115V SERIES
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at:
www.upgnet.com and www.colemanac.com
dditional rating information can be found at:
www.ahridirectory.org
FEATURES
COMMON MP AIR HANDLER AND CM COIL FEATURES
2
RC
- Rigid Case Construction interior endoskeleton for
structural support, smooth side, and locks in insulation.
Powder-painted - G30 galvanized steel case provide a coated
edge that resists corrosion and rust creep.
Quality Construction - Structural components are made of
Aluminum or G90 galvanized steel to prevent corrosion.
Improved Insulation Design - Single piece with no external
screws to reduce thermal transmission paths to prevent
sweating. Foil faced insulation for ease of cleaning.
Case Depth - These models have 20.5” casing which provide
ease of attic access and tight applications.
MP AIR HANDLERS
Factory Sealed - Achieves 2% or less total airflow leakage rate
at duct leakage test conditions in positive and negative
pressure for system airflow verification.
Blowers - All models use direct-drive, multi-speed PSC motors.
CM COILS
MaxAlloyTM Coil - Long life aluminum coils built to deliver
lasting performance, efficiency and reliability.
Thermostatic Expansion Valve - The accessory chatleff style
TXV provides easy installation to convert the indoor coil to the
required refrigerant that does not require brazing to replace or
install. Some models are available with factory installed TXV.
Thermoset Drain Pan - Low retention and positive slope for
drainage to reduce potential mold or contaminants.
Accessories - A full line of matching accessories available for
use with the blower and coils to provide for any type of
application.
WARRANTY SUMMARY
Standard 5-year limited parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replacement
or closing for new home construction.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
2. MOP = Maximum Overcurrent Protection device; must be HACR type circuit breaker or time delay fuse. Refer to the latest edition of the National Electric Code or
in Canada the Canadian electrical Code and local codes to determine correct wire sizing.
FACTORY WIRED TO
FAN MOTOR RELAY
TERMINAL ON
CONTROL BOARD
PRP
FACTORY WIRED TO
TRANSFORMER
ALTERNATE CONNECTION
FOR MP20
CAP
RC
PRP
BRN
BLK
H M L
115 VOLT
BLOWER
MOTOR
GND.
PSC STANDARD MOTOR
FACTORY WIRED TO
FAN MOTOR RELAY
TERMINAL ON
CONTROL BOARD
115 VOLT
BLOWER MOTOR
ALL OTHER AIR HANDLERS
FACTORY WIRED TO
TRANSFORMER
CAP
HIGH
MED
BLK
LOW
BRN
A0460-001
PUR
PUR
GND.
LIMITATIONS
These units must be wired and installed in accordance with all
national and local safety codes.
Voltage limits are as follows:
Air Handler Voltage
110-120-1-60110-120
1. Rated in accordance with ARI Standard 110, utilization range “A”.
1
Normal Operating Voltage Range
Airflow must be within the minimum and maximum limits
approved for electric heat, evaporator coils and outdoor units.
TYPICAL APPLICATIONS
UPFLOW
DOWNFLOW
HORIZONTAL RIGHT
HEAT
HORIZONTAL LEFT
A0458-001
TYPICAL THERMOSTAT CONNECTION
AIR
AIR
THERMOSTAT
R
GG
C
HANDLER
RED
R
GRN
BLU
C
Y
COOLING ONLY
CONDENSING
UNIT
C
Y
THERMOSTAT
R
G
C
HANDLER
RED
R
GRN
G
BLU
C
O
Y
X/L
SINGLE STAGE HEAT PUMP
6Johnson Controls Unitary Products
HEAT
PUMP
R
W
W1/66
C
O
Y
X/L
A0461-001
Page 7
5154297-CTG-C-0216
ACCESSORIES
Refer to Price Manual for specific model numbers where not
shown.
TXV Kits - “Flex-coils” are shipped without a factory installed
metering device. For added flexibility, an R-22 or R-410A TXV
or piston must be field installed to meet your refrigerant choice.
All kits are chatleff style and require no brazing to install.
Breaker Moisture Seal Accessory - A clear circuit breaker
moisture barrier seals the breakers from humidity and dust. The
flexibility of the clear cover allows circuit breakers to be turned
ON or OFF without removing the cover. The cover firmly
attaches to the access panel around the circuit breakers with
the use of double backed adhesive tape. To ensure that
moisture or dust does not contaminate circuit breakers, an S102435672000, Circuit Breaker, Cover Seal may be ordered.
Bottom Rack Filter Kit - The filter frame accessory allows
installation of an external air handler filter in an upflow
application, a downflow application, or a horizontal application
(refer to the following illustration/table for Filter Rack
Dimensions).
Thermostat - Compatible thermostat controls are available
through accessory sourcing. For optimum performance, these
outdoor units are fully compatible with our Coleman touch
screen thermostat with proprietary (patent-pending) hexagon
interface. For more information, see the thermostat section of
the Product Equipment Catalog.
FILTER RACK DIMENSIONS
A
E
C
D
Galvanized
Models
1BR01117
1BR01121
1BR01124
Note: Filters - Not supplied with kit.
ABCDEFiler Size
17.50 21.56 4.00 18.63 14.25 16 x 20 x 1 or 2
21.00 21.56 4.00 18.63 17.75 20 x 20 x 1 or 2
24.50 21.56 4.00 18.63 21.25 20 x 24 x 1 or 2
SIDE
TRACKS
B
11/16
A0146-003
Johnson Controls Unitary Products7
Page 8
AIR FLOW DATA - CFM
1
ModelsCM Models
CM18B
MP08B
CM24B
CM30B
MP12B
CM36B
CM30D
MP14D
MP16C
MP20D
1. Air handler units have been tested to UL 1995 / CSA 22.2 standards up to 0.50" wc. external static pressure.
Dry coil conditions only, tested without filters.
For optimal performance, external static pressures of 0.2" to 0.5" are recommended. Applications above 0.5" are not recommended.