DESCRIPTION
The 16 SEER Series unit is the outdoor part of a versatile climate
system. It is designed with a matching indoor coil component from
Johnson Controls Unitary Products. Available for typical applications, this climate system is supported with accessories and documents to serve specific functions.
FEATURES
• Superior Coil Protection - A stamped, decorative metal coil
guard protects the tube-in-fin coil from debris and other damaging material.
• Protected Compressor - The compressor is safeguarded
against abnormal pressures and temperatures by an internal
pressure relief valve, an internal temperature sensor, and factory high and low pressure system controls. A factory installed
liquid line filter-drier further protects the compressor against
moisture and debris.
• Environmentally Friendly Refrigerant - The next generation
refrigerant R-410A delivers environmentally friendly performance with zero ozone depletion.
• Durable Finish - An automotive quality finish provides the ultimate protection from harmful UV rays and rust creep, ensuring
a long-lasting, high quality appearance. A powder-paint topcoat
is applied over a baked-on primer using a galvanized, zinc
coated steel base material. The result is a finish that has been
proven in testing to provide 33% greater durability than conventional powder-coat finishes.
• Hot Heat Pump - An optional mode that slows the indoor fan
for higher register air temperatures and premium comfort.
• WhisperDrive™ System - Features combination of sweptwing fan, composite base pan, isolated compressor compartment, and single-stage compressor to reduce overall sound to
a mere whisper. The 5-ton system utilizes a two-stage compressor.
• Low RPM Fan Motor - Helps to reduce airflow noise.
• Swept Wing Fan - A fan design boasting technology adapted
from aeronautic and defense engineering provides for whisperquiet operation by allowing air to flow smoothly and efficiently
across the fan tips.
• Composite Base Pan - The strong and durable composite
base pan provides added strength while resisting rust and corrosion, as well as reducing sound and vibration.
• Isolated Compressor Compartment - A molded composite
bulkhead isolates the refrigeration components and the compressor from the rest of the unit, reducing sound and vibration.
• Lower Installed Cost - Designed to provide enhanced installability by featuring a slide-down control compartment that
allows easy access to control components, along with angled
service valves to reduce overall installation time and cost. Factory charged for a 15 foot lineset.
• Factory Installed Filter-Drier - A factory installed, solid core
liquid line filter-drier removes harmful debris and moisture from
the system.
• Easy Service Access - A full end, full service access panel
with handle makes for easy entry to internal components.
• Communications Capable - Requiring only a simple 4-wire
installation, the communicating capability enables the use of
the Touch Screen Communicating Control, allowing real time
visibility of system operation and the use of diagnostic features,
while still maintaining the ability to function with a traditional
thermostat.
• Complete System Control - These heat pumps utilize a
unique microprocessor defrost control system to provide optimal comfort as well as monitor the overall system for reliable
operation. In the event improper operating conditions occur
(high temperature and/or high pressure), the system will automatically shut the system down to extend the life of the heat
pump. The defrost control features an internal memory to aid
the technician in troubleshooting, reducing service time and
cost.
• Premium System Warranty* - Limited lifetime compressor
warranty when registered online within 90 days of installation.
• Agency Listed - Safety certified by CSA to UL 1995 / CSA
22.2. Performance certified to ANSI/AHRI Standard 210/240 in
accordance with the Unitary Small Equipment certification program.
Unit Supply Voltage208-230V, 1 60Hz
Normal Voltage Range
Minimum Circuit Ampacity17.517.322.623.726.933.8
Max. Overcurrent Device Amps
Min. Overcurrent Device Amps
Compressor Type ScrollScrollScrollScrollScroll2-Stage Scroll
Compressor Amps
Crankcase HeaterNoNoNoNoNoNo
Factory External Discharge MufflerYesYesYesYesYesYes
Factory External Check ValveNoNoNoNoNoNo
HS Kit Required with TXV
Fan Motor AmpsRated Load0.71.31.31.31.31.3
Fan Diameter Inches242424242424
Fan Motor
Coil
Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8
Vapor Line Set OD (Field Installed) 3/4 3/4 3/4 7/8 7/81-1/8
Unit Charge (Lbs. - Oz.)
Charge Per Foot, Oz.0.680.680.680.700.700.76
Operating Weight Lbs.199228230237283298
1. Rated in accordance with AHRI Standa rd 110-2012, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard St art Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing leng ths other than 15 feet, add or
subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
only matches, please see the “COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils” table.
FOOTNOTES:
1. For applications requiring a TXV use S1-1TVM*** series kit.
2. A TXV kit must be used with these indoor units to obtain system performance.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit S1-2FD06700224.
4. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
5. Refer to Cooling and Heating Performance Data tables for actual performance for specified system matches.
Note: If a TXV is factory installed on the coil, it must be replaced with the listed TXV.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit, the smallest matched indoor unit, and 15 feet of interconnecting line tubing.
2. Verify the TXV or orifice and additional charge required for specific matched indoor unit in the system using the above t able.
3. Add additional charge for the amount of interconnecting line tubi ng greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For indoor matches requiring additional charge, the refrigerant needs to be weighed in for specific matched indoor unit and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + charge adder for matched indoor unit +
charge adder for line set.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT MODEL
AIR HANDLER
MODELWIDTHSTAGE
COIL
MODEL
1
RATED
CFM
16 SEER HP WITH AIR HANDLERS
AHE60D24.5–
AHV60D24.5–
MV20D24.5FC/MC62D
HC6B060F3(C)
MV20D24.5FC64
MX20D24.5FC/MC62D
MX20D24.5FC64
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80 °F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95 °F outdoor ambient divided by the total electric power in watt-hours at thos e conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electr ic power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb ) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.
* Notates “Hot Heat Pump” performance. These ratings are not AHRI Listed.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
— = Not Applicable.
MA Modular Air Handlers use Coil Only Ratings.
157048.03.743.7633.82.663.729.00
1000*48.03.344.2132.02.523.728.50
163048.03.783.9133.62.703.659.00
1000*48.03.294.3833.62.703.659.00
163048.03.943.7934.02.783.589.00
1000*48.03.454.2634.02.783.589.00
160547.03.863.5733.22.763.529.00
1260*46.93.564.0332.42.623.628.80
160547.03.983.4633.62.823.499.00
1260*46.93.663.9232.62.723.518.85