Coleman FlowClear 90402E Owner's Manual

Page 1
S-S-004232
Email: service@colemanabovegroundpools.com
Website: www.colemanabovegroundpools.com
#90402E
FlowClear
TM
Filter Pump
DO NOT RETURN THIS ITEM TO THE STORE
OR WEBSITE WHERE IT WAS PURCHASED.
CONTACT US DIRECTLY WITH ANY QUESTIONS,
OR FOR DEFECTIVE OR WARRANTY CLAIMS.
CALL US DIRECTLY FOR IMMEDIATE HELP!
TOLL-FREE: 1-855-838-3888 EMAIL: SERVICE@COLEMANABOVEGROUNDPOOLS.COM
4007787
Page 2
WARNING IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
WARNING - RISK OF ELECTRIC SHOCK - The pump cannot be using while people are
inside the pool.
WARNING - TO REDUCE THE RISK OF INJURY, do not permit children to use this
product unless they are closely supervised at all times.
WARNING - RISK OF ELECTRIC SHOCK. Connect only to a grounding type receptacle.
This product is provided with a ground-fault circuit-interrupter. If replacement of the plug is needed, use only identical replacement parts.
WARNING: The unit is provided with a ground-fault circuit-interrupter (GFCI). To test the
GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem corrected by a qualified service representative before using.
CAUTION - To reduce the risk of electric shock the pool must be installed no closer than 6
feet (1.8 m) from any electrical outlet. Do not place portable appliances closer than 5 feet (1.5 m) from the pool.
WARNING: The pump is not intended to be bonded to the equipotential bonding grid.
DO NOT BURY CORD. Locate cord to minimize abuse from lawn mowers, hedge trimmers, and
other equipment.
WARNING - To reduce the risk of electric shock, IF FILTER PUMP POWER CORD
BECOMES DAMAGED IN ANY WAY, THE PUMP MUST BE DISCARDED.
WARNING - To reduce the risk of electric shock, do not use extension cord to connect
unit to electric supply; provide a properly located outlet.
CAUTION - This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage.
CAUTION - For continued protection against possible electric shock this unit is to be
mounted to the base in accordance with the installation instructions.
IMPORTANT - Using the pump with an unmatched electrical supply is dangerous and
will result in catastrophic failure of pump. RISK OF ELECTRIC SHOCK - When working with electricity, turn the electrical power off at the circuit breaker and lock breaker door. Failure to do so will result in increased risk of shock, injury and possibly death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY. DO NOT USE ADAPTOR PLUGS. Consult a qualified electrician for any questions related to the validity of
2
S-S-004232
Page 3
3
your plugs grounding. Handle the pump with care. Do not pull or carry the pump by the power cord. Never pull a plug from the outlet by yanking the power cord. Keep cord free from abrasions. Sharp objects, oil, moving parts, and heat should never be exposed to the filter pump.
NOTE: Please examine equipment before use. Notify Coleman at the customer service
address listed on this manual for any manufacturing defect or missing parts at the time of purchase. Verify that the equipment components represent the filter pump model that you had intended to purchase.
NOTE: Place pump on a solid and level ground. Pay attention to position of pool and pump so
adequate ventilation, drainage, and access for cleaning is available. Never place pump in an area that may accumulate water, or in an area where foot traffic will flow around the pool.
NOTE: Atmospheric conditions may affect the performance and life span of your filter pump.
Unnecessary wear and tear may occur during periods of cold, heat and exposure to sun. Whenever possible shelter the pump from these conditions.
NOTE: Do not add chemicals in the filter pump. NOTE: Assembly and disassembly of this product should only be performed by adults.
• THERMALLY PROTECTED MOTOR CSA ENCLOSURE 3.
• FOR USE WITH SWIMMING POOLS ONLY.
CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK HAZARD,
USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A GROUNDING TYPE
RECEPTACLE.
CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY - DO NOT USE
WITH PERMANENTLY-INSTALLED POOLS.
CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE PROTECTED BY
A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
CAUTION: FOR CONTINUED PROTECTION AGAINST POSSIBLE ELECTRIC
SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.
WARNING - RISK OF ELECTROCUTION
1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin.
2) Inspect Cord Before Using – Do Not Use If Cord Is Damaged.
3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground.
4) Do Not Touch Plug With Wet Hands.
5) Double Insulated – When Servicing Use Only Identical Replacement Parts.
6) Read Instruction Manual Before Using.
DO NOT REMOVE THIS TAG
SAVE THESE INSTRUCTIONS.
S-S-004232
Page 4
4
1 2
3 4
A B C
P6112 P6113 P6(H1)115 P6117 P6119 90357 P6(H1)820E P6019 P6132 P6124 P6005 P6362 P6680 P61318
1 1 1 1 1 1 1 2 2 8 5 1 2 1
1 1 1 1 1 1 1 2 2 5 5 1 0 0
1 1 1 1 1 1 1 2 0 2 2 0 0 0
P6(H1)820E
P6005
P6019
P6124
P6(H1)115
90357
P6117
P6112
P6113
P6119
P6362
P6132
P6680
P61318
A
B
X3
X3
X2 X1 X1
A
B
C
B
B
A
P6362
P6019
P6132
P6132
A
B
A
B
B
A
B
A
B
X2
B
B
A
P61318 P6680
P6124
S-S-004232
Page 5
3 4
PEDESTAL FIXING
The filter pump must be vertically fixed on ground or a certain pedestal made of wood or concrete before use. There should be two holes 9mm in diameter on the pedestal, the space between which should be 166mm. Put filter pump on the pedestal and fix them together by fasten the bolts and nuts. All the pedestal parts should weigh over 18kgs at least to prevent the pump from accidentally falling.
390
166
390
250
166
2-M8 bolt
2-M8 nut
1 2
B
A
P6019
P6019
B
A
A
B
A
B
A
B
B
A
P61318 P6680
B
A
P6124
5
S-S-004232
Page 6
A. To test the GFCI plug, insert it into a grounding type receptacle. B. Press the “RESET” button; the indicator turns red.
NOTE:
If the indicator light is not on, the test has failed.
C. Press the “TEST” button. The indicator turns off.
NOTE:
If the indicator light is not off, the test has failed.
D. Press the “RESET” button, the indicator light turns red, and the filter pump is ready for use.
WARNING:
RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE EACH USE.
WARNING:
DO NOT USE THE PUMP IF THE ABOVE TEST FAILS.
Please contact your
local Coleman Aftersales Service.
NOTE:
To prevent the risk of electrical shock, ensure your hands are completely dry when
plugging-in the Filter Pump.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP - Make sure both the pool’s
Inlet and Outlet valves are fully covered by water before operating the Filter Pump.
MAINTENANCE
CAUTION:
YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY
MAINTENANCE OR STORAGE BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS.
1) Unplug the Filter Pump.
2) Loosen the Hose Clamps on the pool’s Inlet and Outlet Hoses by unscrewing the fly nut counter-clockwise.
3) Remove Debris Screens from the inside of the pool.
4) Replace the Debris Screens with the Stopper Plugs in the pool’s Inlet and Outlet Valves.
5)
Unscrew the Filter Cap Retainer and remove the Filter Cap.
6)
Clean the Filter Cartridge with a garden hose, if filter cartridge remains soiled or discolored, it is necessary to replace it with a new one.
7)
Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
8)
Check that the Filter Cap Seal is in place.
9)
Replace the Filter Cap and screw the Filter Cap Retainer into position.
10) Replace the Stopper Plugs with the Debris Screens in the pool’s Inlet and Outlet Valves. Tighten the Hose Clamps. Water will now flow to the pump.
11) Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use.
IMPORTANT:
For sanitary reasons we suggest replacing the Filter Cartridge with a new
one every two weeks.
PUMP STORAGE
1) Unplug the Filter Pump.
2)
Follow the instructions as previously outlined to stop water flowing to the Filter Pump and to remove the Filter Cartridge.
3) Discard the Filter Cartridge.
4) Detach all Hoses.
5) Dry all components thoroughly.
6) Store the filter pump in a dry location out of the reach of children. Storage temperature: 4-40 ºC (39.2-104F)
PUMP WARRANTY
For information concerning pump warranty please visit our website at: www.colemanabovegroundpools.com
NOTE:
It is imperative to check that the hydraulic connectors are not closed.
GFCI Test
RESET
TEST
RESET
TEST
RESET
TEST
A B C D
6
S-S-004232
Page 7
The product you have purchased comes with a limited warranty. Coleman® stands behind our quality guarantee and assures, through a replacement warranty, your product will be free from manufacturer’s defects. The limited warranty is valid as follows:
360 days for the motor pumps, 30 days for hoses, fitting and accessory included in the package, from the original date of purchase.
To file a warranty claim, this form must be completed and submitted with a copy of your receipt/purchase and emailed to service@colemanabovegroundpools.com. Please contact your Coleman® After Sales Center at 1-855-838-3888 before sending any documents. They will provide full instructions of what is needed for your claim. Coleman® is not responsible for economic loss due to water or chemical costs and will not replace any products deemed to have been neglected or having been used outside of the owner’s manual guidelines. Coleman’s warranty covers manufacturing defects discovered while unpacking the product or during use, as recommended within the user manual. This warranty applies only to products that have not been modified by any 3rd parties. The product must be stored and handled in accordance with the technical recommendations. The warranty does not cover damages caused by misuse, abuse, neglect, including but not limited to: collision, fire, excessive heat exposure, improper use of chemicals, exposure to extreme weather conditions, improper installation, or improper storage. Replacements and repairs don’t extend the duration of warranty. The warranty start date is the date of sale shown on the original receipt/ purchase invoice.
L
I
M
I
T
E
D
W
A
R
R
A
N
T
Y
360 DAYS ON PUMP
Coleman® reserves the right to request photographic evidence of defective parts, or to require sending the item for additional testing. In order to best assist you, we request all information you provided to be complete.
VISIT OUR WEBSITE WWW.COLEMANABOVEGROUNDPOOLS.COM TO BUY SPARE PARTS, TO DOWNLOAD MANUALS, FAQ AND VIDEO.
IMPORTANT: ONLY THE DAMAGED PART WILL BE REPLACED, NOT THE COMPLETE SET.
Please copy the Batch Number found on the body of the filter pump.
BATCH NUMBER:
TO: Coleman® Service Department
Date of purchase:
Date:
Customer Code Number:
Please Clearly Write Your Item Code:
Website: www.colemanabovegroundpools.com Customer Service: service@colemanabovegroundpools.com Toll-Free:1-855-838-3888 Please provide your address details in full. Note: Incomplete address details will result in delayed shipments. Coleman® reserves the right to charge for redelivery of undelivered packages where the recipient is at fault.
REQUIRED INFORMATION - PLEASE WRITE THE SHIPPING ADDRESS
Name:
Zip code: Retailer:
Country:
Mobile:
Fax:
Address:
City:
Telephone:
E-mail:
Batch Number
Batch Number
Batch Number
Item Code
#XXXXX
POOL FILTER PUMP
MODEL
7
S-S-004232
Page 8
© 2015 The Coleman Company, Inc.
and are registered trademarks of The Coleman Company, Inc., used under license.
Manufactured by
©2015 Bestway (USA) Inc., 3411 E. Harbour Drive, Phoenix, Arizona 85034, United States of America
®™ Trademarks used in some countries under license to
Bestway Inflatables & Material Corp., No.3065 Cao An Road, Shanghai, 201812, China
www.bestwaycorp.com
S-S-004232
Loading...