These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
TECHNICAL GUIDE
Echelon
MODELS: FC9M*UP
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
UPFLOW MODULATING FURNACES
NATURAL GAS
60 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
WARRANTY
Lifetime limited warranty on both heat exchangers to the original purchaser; a 20-year limited warranty from original installation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial applications.
5-year limited parts warranty.
FEATURES
• Modulating heating operation includes:
- Modulating gas valve
- Modulating inducer operation
• Provides increased comfort level & very quiet unit operation
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement application.
• Integrated control module for reliable, economical operation.
• May be installed as either two-pipe (direct vent) or single
pipe vent (using indoor combustion air)
• Top intake & vent connection allows installation in narrow
locations.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• Induced combustion system with inshot main burners for
quiet, efficient operation.
• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• PSC -four speed, direct drive motor with large, quiet
blower.
• 24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
* ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
NOTES:
1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.
5. Air flows above 1800 CFM require either return from two sides or one side plus bottom.
Unitary Products Group3
259720-CTG-B-0108
For additional connection diagrams for all UPG e quipment refer to “Line Voltage System Wiring” document available on-line at
www.upgnet.com in the Product Catalog Section.
AC 11ASingle Stage Air Conditioner – PSC Modulating Furnace
ID MODELS
PM9
FC9M
THERMOSTAT
FL9M
*PP11C70224
Y
Full Stage Compressor
RH
24 – Volt Hot
(Heat XFMR)
G
Fan
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
HM1
Humidistat
24VAC Humidifier
(Optional)
PSC
MODULATING
FURNACE
PSC
MODULATING FURNACE
C
24 – Volt Common
Y/Y2
Second or Full
Stage Compressor
R
24 – Volt Hot
G
Fan
W
Modulating Heat
Single Stage Compressor
Y1
SINGLE STAGE
SINGLE STAGE
AIR
AIR CONDITIONER
CONDITIONER
SINGLE STAGE
1
SINGLE STAGE
AIR CONDITIONER
AIR CONDITIONER
C
24 – Volt Common
Y
Y
Compressor
Compressor Contactor
Clipping Jumper W914 for
electric heat on thermostat
is not necessary
Thermostat Chart - PSC Modulating Furnace/Single Stage Air Conditioner
4Unitary Products Group
Part Numbers:
SAP = Legacy
155941 = 031-09140
1
AC 11BSingle Stage Air Conditioner – PSC Modulating Furnace
ID MODELS
PM9
FC9M
THERMOSTAT
THERMOSTAT
FL9M
259720-CTG-B-0108
*BN11C00124
C
24 – Volt Common
Y
Full Stage Compressor
RH
24 – Volt Hot
(Heat XFMR)
G
Fan
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
*BP11C50124
*BN11C01124
*DP11C40124
*DN11C00124
C
24 – Volt Common
Y
Full Stage Compressor
RH
24 – Volt Hot
(Heat XFMR)
G
Fan
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
PSC
MODULATING
FURNACE
PSC
MODULATING FURNACE
C
24 – Volt Common
Y/Y2
Second or Full
Stage Compressor
R
24 – Volt Hot
G
Fan
W
Modulating Heat
Single Stage Compressor
Y1
SINGLE STAGE
AIR
CONDITIONER
1
SINGLE STAGE
AIR CONDITIONER
C
24 – Volt Common
Y
Compressor Contactor
External Humidistat
Thermostat Installer Setup
1-System Type-must be
set to 0
Thermostat Installer Setup
15-Compressor Protection
must be set to 5
2
2
(Optional)
Open on Humidity Rise
Selection of GAS/ELEC
switch on thermostat
is not necessary
Part Number:
S1-2HU16700124
24VAC Humidifier
(Optional)
Part Numbers:
SAP = Legacy
155941 = 031-09140
1
Thermostat Chart - PSC Modulating Furnace/Single Stage Air Conditioner
Unitary Products Group5
259720-CTG-B-0108
AC 11CSingle Stage Air Conditioner – PSC Modulating Furnace
Blower speed adjustments should be done by moving the COOL jumper on the control
board. DO NOT move the motor wires to different positions on the furnace control board.
NOTES:
1. Airflow expressed in standard cubic feet per minute (CFM).
2. Return air is through side opposite motor (left side).
3. In order to stay within the velocity rating the filters, airflows above 1800 CFM require eit her return from two sides or one side plus bottom.
4. Motor voltage at 115 V.
FILTER PERFORMANCE
FILTER PERFORMANCE - PRESSURE DROP INCHES W.C.
The airflow capacity data published in the “Blower Performance” table listed above represents blower performance
WITHOUT filters. To determine the approximate blower performance of the system, apply the filter drop value for the filter being used or select an appropriate value from the “Filter
Performance” table shown.
NOTE: The filter pressure drop values in the “Filter Performance” table shown are typical values for the type of filter
listed and should only be used as a guideline. Actual pressure drop ratings for each filter type vary between filter manufacturer.
APPLYING FILTER PRESSURE DROP TO
DETERMINE SYSTEM AIRFLOW
To determine the approximate airflow of the unit with a filter in
place, follow the steps below:
1.Select the filter type.
2.Select the number of return air openings or calculate the
return opening size in square inches to determine the
proper filter pressure drop.
3.Determine the External System Static Pressure (ESP)
without the filter.
4.Select a filter pressure drop from the table based upon
the number of return air openings or return air opening
size and add to the ESP from Step 3 to determine the
total system static.
5.If total system static matches a ESP value in the airflow
table (i.e. 0.20, 0.60, etc,) the system airflow corresponds to the intersection of the ESP column and Model/
Blower Speed row .
6.If the total system static falls between ESP values in the
table (i.e. 0.58, 0.75, etc.), the static pressure may be
rounded to the nearest value in the table determining the
airflow using Step 5 or calculate the airflow by using the
following example.
Example: For a 120,000 Btuh furnace with 2 return openings
and operating on high speed blower, it is found that total system static is 0.58" w.c. To determine the system airflow, complete the following steps:
1.Obtain the airflow values at 0.50" & 0.60" ESP.
Airflow @ 0.50": 2285 CFM
Airflow @ 0.60": 2175 CFM
2.Subtract the airflow @ 0.50" from the airflow @ 0.60" to
obtain airflow difference.
2175 - 2285 = -110 CFM
3.Subtract the total system static from 0.50" and divide this
difference by the difference in ESP values in the table,
0.60" - 0.50", to obtain a percentage.
(0.58 - 0.50) / (0.60 - 0.50) = 0.8
4.Multiply percentage by airflow difference to obtain airflow
reduction.
(0.8) x (-110) = -88
5.Subract airflow reduction value to airflow @ 0.50" to
obtain actual airflow @ 0.58" ESP.
2288 - 88 = 2197
UNIT CLEARANCES TO COMBUSTIBLES
APPLICATION
UPFLOW130000COMBUSTIBLEYESYES
ACCESSORIES
PROPANE (LP) CONVERSION KIT 1NP0680 - All units
This accessory conversion kit must be used to convert natural gas (N) units for propane (LP) operation. Conversions
must be made by qualified distributor or dealer personnel.
CONCENTRIC VENT TERMINATION -
1CT0302 (2")
1CT0303 (3")
For use through rooftop, sidewall. Allows combustion air to
enter and exhaust to exit through single common hole.
CONDENSATE NEUTRALIZER KIT - 1NK0301
Neutralizer cartidge has a 1/2" plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also
avaiable from the Source 1 Parts (p/n 026-30228-000).
SIDEWALL VENT TERMINATION -
1HT0901 (3")
TOPFRONTREARLEFT SIDERIGHT SIDEFLUE
In.In.In.In.In.In.
SIDE RETURN FILTER -
1SR0402 - All Models
1SR0200 - All Models
BOTTOM RETURN FILTER -
1BR0117 or 1BR0217 - For 17-1/2” cabinets
1BR0121 or 1BR0221 - For 21” cabinets
1BR0124 or 1BR0224 - For 24-1/2” cabinets
ROOM THERMOSTATS - A wide selection of compatible
thermosets are available to provide optimum performance
and features for any installation.