DESCRIPTION
These Category IV, highly efficient, compact, condensing type furnaces are designed for residential and commercial installations in a basement, closet, alcove, recreation room or garage where the ambient temperature is above 32°F, or higher. They may be either side wall or thru-roof vented using approved plastic type combustion air and vent piping. All units are factory assembled, wired and tested to assure dependable and economical installation and operation.
TECHNICAL GUIDE
Echelon MODELS: FC9M*UP
GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW MODULATING FURNACES
NATURAL GAS 60 - 120 MBH INPUT
EFFICIENCY RATING CERTIFIED
ISO 9001
Certified Quality
Management System
Visit us on the web at www.york.com for the most up-to-date technical information.
Additional rating information can be found at www.gamanet.org.
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig­inal purchaser; a 20-year limited warranty from original instal­lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli­cations.
5-year limited parts warranty.
FEATURES
• Modulating heating operation includes:
- Modulating gas valve
- Modulating inducer operation
• Provides increased comfort level & very quiet unit opera­tion
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica­tion.
• Integrated control module for reliable, economical opera­tion.
• May be installed as either two-pipe (direct vent) or single pipe vent (using indoor combustion air)
• Top intake & vent connection allows installation in narrow locations.
• Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.
• Induced combustion system with inshot main burners for quiet, efficient operation.
• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• PSC -four speed, direct drive motor with large, quiet blower.
• 24V, 40 VA control transformer and blower relay supplied for add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high­grade stainless steel.
• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance or service.
• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
259720-CTG-B-0108
26-1/2 24-5/8
1-1/2” GAS PIPE ENTRY
7/8” JUNCTION BOX HOLE
T-STAT WIRING 7/8” K.O.
CONDENSATE DRAIN 7/8” K.O.
OPTIONAL RETURN AIR CUT-OUT (either side) FOR USE WITH EXTERNAL FILTER FRAME
7/8
LEFT SIDE
23-3/4
30-1/8
11
7
21-1/2
13-7/8
7/8
26-3/4
BOTTOM IMAGE
RETURN END
30-7/8
FRONT
1-3/8
C
A
1-1/4
40
28-3/8
21-1/2
11
8
24-3/8
20
D
2
24-7/16
TOP IMAGE
SUPPLY END
5/8
5/8
B
26-1/2
25-3/8
1-1/2” GAS PIPE ENTRY
7/8” JUNCTION BOX HOLE
T-STAT WIRING 7/8” K.O.
CONDENSATE DRAIN 7/8” K.O.
RIGHT SIDE
DIMENSIONS
Models
Nominal
CFM
Cabinet
Size
A (in.) B (in.) C (in.) D (in.) FC9M060B12UP11 1200 B 17-1/2 16-1/4 14-1/2 8-1/2 FC9M080B12UP11 1200 B 17-1/2 16-1/4 11 8-1/2 FC9M080C16UP11 1600 C 21 19-3/4 18 8-7/8 FC9M100C16UP11 1600 C 21 19-3/4 18 8-7/8 FC9M100C20UP11 2000 C 21 19-3/4 18 8-7/8 FC9M120D20UP11 2000 D 24-1/2 23-1/4 21-1/2 10-5/8
Cabinet Dimension
2 Unitary Products Group
ELECTRICAL AND PERFORMANCE DATA
259720-CTG-B-0108
Models
Input
Max/Min
MBH MBH In. HP Amps °F °F
Output
Max/Min
Blower
Size
Blower
Max.
Over-current
Protect
Air Temp. Rise
Maximum Input
Air Temp. Rise
Minimum Input
FC9M060B12UP11 60/21 57/20 11 x 8 1/2 7.7 20 40 - 70 20 - 50 FC9M080B12UP11 80/28 76/26 11 x 8 1/2 7.7 20 40 - 70 20 - 50 FC9M080C16UP11 80/28 76/26 11 x 10 3/4 10.2 20 40 - 70 20 - 50 FC9M100C16UP11 100/35 95/33 11 x 10 3/4 10.2 20 40 - 70 20 - 50 FC9M100C20UP11 100/35 95/33 11 x 11 1 12.8 20 40 - 70 20 - 50 FC9M120D20UP11 120/42 115/39 11 x 11 1 12.8 20 40 - 70 20 - 50
Models
Max. Outlet
Air Temp.
°F CFM In. Amps %
Nominal
Airflow
Cabinet
Width
Total
Unit
AFUE
Min. Wire Size
(awg) @ 75 ft.
One Way
Approximate
Operating Weight
Power Supply
(Voltage-PH-Hz)
FC9M060B12UP11 170 1200 17-1/2 9 95.0 14 135 115-1-60 FC9M080B12UP11 170 1200 17-1/2 9 95.0 14 142 115-1-60 FC9M080C16UP11 170 1600 21 12 95.0 14 157 115-1-60 FC9M100C16UP11 170 1600 21 12 95.0 14 162 115-1-60 FC9M100C20UP11 170 2000 21 14 95.0 12 164 115-1-60 FC9M120D20UP11 170 2000 24-1/2 14 95.0 12 180 115-1-60
* ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil. Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water.
NOTES:
1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.
5. Air flows above 1800 CFM require either return from two sides or one side plus bottom.
Unitary Products Group 3
259720-CTG-B-0108 For additional connection diagrams for all UPG e quipment refer to “Line Voltage System Wiring” document available on-line at
www.upgnet.com in the Product Catalog Section.
AC 11A Single Stage Air Conditioner – PSC Modulating Furnace
ID MODELS
PM9
FC9M
THERMOSTAT
FL9M
*PP11C70224
Y
Full Stage Compressor
RH 24 – Volt Hot (Heat XFMR)
G
Fan
RC 24 – Volt Hot (Cool XFMR)
W
Full Stage Heat
HM1
Humidistat
24VAC Humidifier
(Optional)
PSC
MODULATING
FURNACE
PSC
MODULATING FURNACE
C
24 – Volt Common
Y/Y2
Second or Full
Stage Compressor
R
24 – Volt Hot
G
Fan
W
Modulating Heat
Single Stage Compressor
Y1
SINGLE STAGE SINGLE STAGE
AIR
AIR CONDITIONER
CONDITIONER
SINGLE STAGE
1
SINGLE STAGE
AIR CONDITIONER
AIR CONDITIONER
C
24 – Volt Common
Y
Y
Compressor
Compressor Contactor
Clipping Jumper W914 for electric heat on thermostat
is not necessary
Thermostat Chart - PSC Modulating Furnace/Single Stage Air Conditioner
4 Unitary Products Group
Part Numbers:
SAP = Legacy
155941 = 031-09140