259720-CTG-B-0108
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
TECHNICAL GUIDE
Echelon
MODELS: FC9M*UP
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
UPFLOW MODULATING FURNACES
NATURAL GAS
60 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
WARRANTY
Lifetime limited warranty on both heat exchangers to the original purchaser; a 20-year limited warranty from original installation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial applications.
5-year limited parts warranty.
FEATURES
• Modulating heating operation includes:
- Modulating gas valve
- Modulating inducer operation
• Provides increased comfort level & very quiet unit operation
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement application.
• Integrated control module for reliable, economical operation.
• May be installed as either two-pipe (direct vent) or single
pipe vent (using indoor combustion air)
• Top intake & vent connection allows installation in narrow
locations.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• Induced combustion system with inshot main burners for
quiet, efficient operation.
• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• PSC -four speed, direct drive motor with large, quiet
blower.
• 24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C highgrade stainless steel.
• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance or
service.
• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

259720-CTG-B-0108
26-1/2
24-5/8
1-1/2” GAS
PIPE ENTRY
7/8” JUNCTION
BOX HOLE
T-STAT WIRING
7/8” K.O.
CONDENSATE
DRAIN 7/8” K.O.
OPTIONAL RETURN AIR
CUT-OUT (either side)
FOR USE WITH
EXTERNAL FILTER
FRAME
7/8
LEFT SIDE
23-3/4
30-1/8
11
7
21-1/2
13-7/8
7/8
26-3/4
BOTTOM IMAGE
RETURN END
30-7/8
FRONT
1-3/8
C
A
1-1/4
40
28-3/8
21-1/2
11
8
24-3/8
20
D
2
24-7/16
TOP IMAGE
SUPPLY END
5/8
5/8
B
26-1/2
25-3/8
1-1/2” GAS
PIPE ENTRY
7/8” JUNCTION
BOX HOLE
T-STAT WIRING
7/8” K.O.
CONDENSATE
DRAIN 7/8” K.O.
RIGHT SIDE
DIMENSIONS
Models
Nominal
CFM
Cabinet
Size
A (in.) B (in.) C (in.) D (in.)
FC9M060B12UP11 1200 B 17-1/2 16-1/4 14-1/2 8-1/2
FC9M080B12UP11 1200 B 17-1/2 16-1/4 11 8-1/2
FC9M080C16UP11 1600 C 21 19-3/4 18 8-7/8
FC9M100C16UP11 1600 C 21 19-3/4 18 8-7/8
FC9M100C20UP11 2000 C 21 19-3/4 18 8-7/8
FC9M120D20UP11 2000 D 24-1/2 23-1/4 21-1/2 10-5/8
Cabinet Dimension
2 Unitary Products Group

ELECTRICAL AND PERFORMANCE DATA
259720-CTG-B-0108
Models
Input
Max/Min
MBH MBH In. HP Amps °F °F
Output
Max/Min
Blower
Size
Blower
Max.
Over-current
Protect
Air Temp. Rise
Maximum Input
Air Temp. Rise
Minimum Input
FC9M060B12UP11 60/21 57/20 11 x 8 1/2 7.7 20 40 - 70 20 - 50
FC9M080B12UP11 80/28 76/26 11 x 8 1/2 7.7 20 40 - 70 20 - 50
FC9M080C16UP11 80/28 76/26 11 x 10 3/4 10.2 20 40 - 70 20 - 50
FC9M100C16UP11 100/35 95/33 11 x 10 3/4 10.2 20 40 - 70 20 - 50
FC9M100C20UP11 100/35 95/33 11 x 11 1 12.8 20 40 - 70 20 - 50
FC9M120D20UP11 120/42 115/39 11 x 11 1 12.8 20 40 - 70 20 - 50
Models
Max. Outlet
Air Temp.
°F CFM In. Amps %
Nominal
Airflow
Cabinet
Width
Total
Unit
AFUE
Min. Wire Size
(awg) @ 75 ft.
One Way
Approximate
Operating Weight
Power Supply
(Voltage-PH-Hz)
FC9M060B12UP11 170 1200 17-1/2 9 95.0 14 135 115-1-60
FC9M080B12UP11 170 1200 17-1/2 9 95.0 14 142 115-1-60
FC9M080C16UP11 170 1600 21 12 95.0 14 157 115-1-60
FC9M100C16UP11 170 1600 21 12 95.0 14 162 115-1-60
FC9M100C20UP11 170 2000 21 14 95.0 12 164 115-1-60
FC9M120D20UP11 170 2000 24-1/2 14 95.0 12 180 115-1-60
* ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
NOTES:
1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.
5. Air flows above 1800 CFM require either return from two sides or one side plus bottom.
Unitary Products Group 3

259720-CTG-B-0108
For additional connection diagrams for all UPG e quipment refer to “Line Voltage System Wiring” document available on-line at
www.upgnet.com in the Product Catalog Section.
AC 11A Single Stage Air Conditioner – PSC Modulating Furnace
ID MODELS
PM9
FC9M
THERMOSTAT
FL9M
*PP11C70224
Y
Full Stage Compressor
RH
24 – Volt Hot
(Heat XFMR)
G
Fan
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
HM1
Humidistat
24VAC Humidifier
(Optional)
PSC
MODULATING
FURNACE
PSC
MODULATING FURNACE
C
24 – Volt Common
Y/Y2
Second or Full
Stage Compressor
R
24 – Volt Hot
G
Fan
W
Modulating Heat
Single Stage Compressor
Y1
SINGLE STAGE
SINGLE STAGE
AIR
AIR CONDITIONER
CONDITIONER
SINGLE STAGE
1
SINGLE STAGE
AIR CONDITIONER
AIR CONDITIONER
C
24 – Volt Common
Y
Y
Compressor
Compressor Contactor
Clipping Jumper W914 for
electric heat on thermostat
is not necessary
Thermostat Chart - PSC Modulating Furnace/Single Stage Air Conditioner
4 Unitary Products Group
Part Numbers:
SAP = Legacy
155941 = 031-09140
1