Coleman LC8T-UH, FC8T-UH User Manual

TECHNICAL GUIDE
Echelon MODELS: FC8T-UH/LC8T-UH
GAS-FIRED HIGH EFFICIENCY TWO STAGE UPFLOW/HORIZONTAL FURNACES
STANDARD & Low NOx 80% AFUE
EFFICIENCY RATING CERTIFIED
ISO 9001
Certified Quality
Management System
Due to continuous product improvement, specifications are subject to change without notice.
Visit us on the web at www.york.com for the most up-to-date technical information.
Additional rating information can be found at www.gamanet.org.
246756-CTG-C-0407
DESCRIPTION
These high efficiency, compact units employ induced com­bustion, reliable hot surface ignition and high heat transfer tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications.
These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe depend­able and economical installation and operation.
These units are Category I listed and may be common vented with another gas appliance as allowed by the National Fuel Gas Code.
WARRANTY
20-year limited warranty on the heat exchanger. 10-year heat exchanger warranty on commercial applica­tions. 5-year limited parts warranty.
FEATURES
Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
- Two speed blower operation
Provides increased comfort level & very quiet unit oper­ation
Adjustable delay timer allows two stage operation with single stage thermostat
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-
tion.
• Integrated control module for reliable, economical opera-
tion.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• Induced combustion system with inshot main burners for
quiet, efficient operation.
• 100% shut off main gas valve for extra safety.
• PSC -four speed, direct drive motor with large, quiet
blower.
• 24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Timed on, adjustable off blower capability for maximum
comfort.
• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance
or service.
• Insulated blower compartment for quiet operation.
• Independent door removal for greater durability and ease
of access.
• Low NOx models have been designed to meet specific
code requirements.
• Low NOx models may not be converted to propane unless
screens are removed.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
246756-CTG-C-0407
B
A
FRONT
3/4
40
26-3/4
20
13-3/4
GAS INLET 1-1/4 x 2-1/2
T’STAT WIRING 7/8” K.O.
30-1/8
LEFT SIDE
1-1/2
1-1/4
4” Diameter
(VENT CONNECTIONS)
POWER WIRING 7/8” HOLE
2-1/2
32-1/2
ACCESS WIRING 7/8” K.O.
16
8-3/4
20
5-3/8
2
5/8
14
23-1/2
RIGHT SIDE
5/8
14-3/4
2-1/4
1-1/8
BOTTOM IMAGE
RETURN END
C
4” Diameter
D
24-3/4
TOP IMAGE
SUPPLY END
B
CABINET AND DUCT DIMENSIONS
Models CFM Cabinet Size
ABCD
FC8T040A12UH11 1200 A 14 1/2 13 1/4 11 1/2 10 1/8 (F,L)C8T060A12UH11 1200 A 14 1/2 13 1/4 11 1/2 10 1/8 (F,L)C8T080A12UH11 1200 A 14 1/2 13 1/4 11 1/2 10 1/8 (F,L)C8T080B16UH11 1600 B 17 1/2 16 1/4 14 1/2 11 5/8 (F,L)C8T080C16UH11 1600 C 21 19 3/4 18 13 3/8
FC8T100B12UH11 1200 B 17 1/2 16 1/4 14 1/2 11 5/8 (F,L)C8T100C20UH11 2000 C 21 19 3/4 18 13 3/8
FC8T120C16UH11 1600 C 21 19 3/4 18 13 3/8 (F,L)C8T120C20UH11 2000 C 21 19 3/4 18 13 3/8
Cabinet Dimension
RATINGS & PHYSICAL / ELECTRICAL DATA
Blower
Size
Operation
Weight
Models
Input/Cabinet
High/Low
Output BTU/H
High/Low
Nominal
Airflow
Cabinet Width
AFUE
MBH MBH CF M In Hp Amps In
FC8T040A12UH11 (F,L)C8T060A12UH11 (F,L)C8T080A12UH11 (F,L)C8T080B16UH11 (F,L)C8T080C16UH11
FC8T100B12UH11 (F,L)C8T100C20UH11
FC8T120C16UH11 (F,L)C8T120C20UH11
Models
FC8T040A12UH11 (F,L)C8T060A12UH11 (F,L)C8T080A12UH11 (F,L)C8T080B16UH11 (F,L)C8T080C16UH11
FC8T100B12UH11 (F,L)C8T100C20UH11
FC8T120C16UH11 (F,L)C8T120C20UH11
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water.
40/26 32/21 1200 14-1/2 80.0 1/2 7.7 10 x 8 57/42 46/34 1200 14-1/2 80.0 1/2 7.7 10 x 8 80/59 64/48 1200 14 1/2 80.0 1/2 7.7 10 x 8 80/59 64/48 1600 17-1/2 80.0 3/4 11.5 10 x 10
80/59 64/48 1600 21 80.0 3/4 11.5 10 x 10 100/65 80/53 1200 17 1/2 80.0 1/2 11.5 10 x 10 100/65 80/53 2000 21 80.0 1 14 11 x 10 120/78 96/64 1600 21 80.0 3/4 11.5 11 x 10 120/78 96/64 2000 21 80.0 1 14 11 x 11
Input/Cabinet
High/Low
MBH °F °F °F Lbs
Max. Outlet
Air Temp
Low Fire
Air Temp. Rise
High Fire
Air Temp. Rise
Unit
Amps
Max
Over-Current
Protect
40/26 150 15-45 20-50 9.0 20 14 107
57/42 160 25-55 35-65 9.0 20 14 107
80/52 175 30-60 40-70 9.0 20 14 117
80/59 160 25-55 25-55 12.0 20 14 129
80/59 160 25-55 25-55 12.0 20 14 130 100/65 170 25-55 40-70 12.0 20 14 128 100/65 170 25-55 40-70 12.0 20 14 145 120/78 180 25-55 45-75 12.0 20 14 145 120/78 170 25-55 35-65 14.0 20 12 147
Blower
Min. wire Size
(awg) @ 75 ft
one way
2 Unitary Products Group
BLOWER PERFORMANCE CFM - UPFLOW (WITHOUT FILTER) - BOTTOM RETURN
Bottom Airflow Data (SCFM)
Models Speed
High 1610 1540 1460 1360 1290 1200 1110 1020 900 760
FC8T040A12UH11
Medium High 1430 1390 1330 1250 1190 1110 1030 940 840 710 Medium Low 1200 1180 1140 1100 1 050 1000 930 850 750 620
Low 980 980 960 920 890 840 790 720 620 530
High 1570 1490 1420 1340 1250 1180 1090 990 870 700
(F,L)C8T060A12UH11
Medium High 1410 1360 1310 1250 1190 1090 1020 920 810 650
Medium Low 1200 1180 1150 1100 1050 990 920 830 700 580
Low 960 960 950 930 900 840 800 720 610 500 High 1590 1520 1460 1380 1300 1240 1150 1050 930 800
(F,L)C8T080A12UH11
Medium High 1400 1360 1310 1260 1200 1140 1070 960 860 740
Medium Low 1180 1160 1130 1090 1040 990 920 840 750 640
Low 940 940 940 920 880 840 790 710 630 530 High 1850 1820 1790 1750 1690 1630 1570 1500 1430 1330
(F,L)C8T080B16UH11
Medium 1470 1450 1440 1430 1390 1360 1310 1270 1220 1150
Low 1260 1260 1260 1260 1250 1200 1150 1110 1070 1010 High 2077 1992 1922 1830 1727 1617 1507 1355 1219 1050
(F,L)C8T080C16UH11
Medium 1729 1673 1631 1581 1507 1421 1293 1187 1053 907
Low 1448 1452 1432 1390 1324 1264 1176 1058 939 774 High 1700 1620 1560 1480 1390 1300 1210 1110 970 820
FC8T100B12UH11
Medium High 1430 1400 1350 1300 1230 1160 1080 980 870 710
Medium Low 1180 1170 1160 1130 1080 1030 1000 860 750 510
Low 950 950 930 920 880 840 790 720 620 530 High 2590 2500 2400 2280 2180 2080 1970 1840 1720 1560
(F,L)C8T100C20UH11
Medium High 2180 2120 2040 1980 1900 1810 1720 1600 1480 1320
Medium Low 1750 1720 1680 1640 1580 1520 1440 1350 1220 1060
Low 1450 1420 1380 1330 1300 1240 1160 1070 970 860 High 2020 1930 1820 1730 1640 1540 1400 1250 1090 920
FC8T120C16UH11
Medium 1750 1710 1650 1590 1490 1390 1290 1160 1010 810
Low 1540 1500 1460 1410 1350 1260 1180 1060 910 750 High 2500 2400 2320 2220 2110 2000 1870 1750 1610 1450
(F,L)C8T120C20UH11
Medium High 2130 2070 1990 1920 1840 1760 1660 1570 1460 1320
Medium Low 1700 1680 1650 1620 1560 1500 1410 1320 1210 1070
Low 1420 1390 1360 1330 1290 1240 1150 1060 950 840
NOTES:
1. Airflow expressed in standard cubic feet per minute.
2. Motor voltage at 115 V .
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0