Coleman CM01213-15, CM 01205-11 Operator's Manual

Manufactured in China Toll Free Helpline: 1-855-900-2653 ©2010 Alton Industry Ltd. Group – All Rights Reserved
R
and are registered trademarks of The Coleman Company, Inc. used under
license. ©2010 The Coleman Company, Inc.
15GAL AIR COMPRESSOR
3.5HP/15-GALLON
IMPORTANT: READ OPERATOR’S MANUAL BEFORE USING
OPERATOR’S MANUAL
Cat.02315 34
TABLE OF CONTENTS
SAFETY GUIDELINES----------------------------------------------------------------------------------------------3 BASIC COMPRESSOR FEATURES
---------------------------------------------------------------------------4
ELECTRIC MOTOR------------------------------------------------------------------------------------------------- ----5 AIR COMPRESSOR PUMP-------------------------------------------------------------------------------------------5 PRESSURE SWITCH --------------------------------------------------------------------------------------------------5 PRESSURE RELIEF VALVE------------------------------------------------------------------------------------------5 AIR PRESSURE REGULATOR--------------------------------------------------------------------------------------5 TANK PRESSURE GAUGE-------------------------------------------------------------------------------------------5 REGULATED PRESSURE GAUGE---------------------------------------------------------------------------------5 AIR LINE OUTLET----------------------------------------------------------------------------------- --------------------5 AIR TANK DRAIN VALVE----------------------------------------------------------------------------------------------5 AIR TANK------------------------------------------------------------------------------------------------------------------5 POWER CORD-------------------------------- ---------------------------------------------------------------------------5
ASSEMBLY--------------------------------------------------------------------------------------------------------------6 OPERATION
------------------------------------------------------------------------------------------------------------7
PRIMING THE PUMP------------------------------------------------------------------------------------------------7
STARTUP------------------------------------------------------------------------------------------------------------------7 SHUTDOWN--------------------------------------------------------------------------------------------------------------7
MAINTENANCE CH A RT--------------------------------------------------------------------------------------------8 TROUBLESHOOTING CHART
-----------------------------------------------------------------------------------9
PARTS DRAWING&PRATS LIST-------------------------------------------------------------------------------10
WARRANTY-------------------------------------------------------------------------------------------------11
SPECIFICATION
ITEM NO. --------------------------------------CM 01213-15 PUMP-------------------------------------------OIL LUBE DIRECT DRIVE MOTOR-----------------------------------------2.5 Continuous HP VOL TAGE/AMPS/PHASE------------------120/15/1 AIR T ANK CAPACITY-----------------------15 GALLON CUT-IN PRESSURE-------------------------95 PSI CUT-OUT PRESSURE---------------------125 PSI CFM @ 40 PSI--------------------------------5.0 CFM @ 90 PSI--------------------------------4.0 POWER CORD-------------------------------STW 14 AWG / 72” LENGTH
NOTE: Avoid use of extension cords. If cannot be avoided, the cord should be a minimum
wire size of 12 AWG and no longer than 50 feet. Use only a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product.
- 2-
SAFETY GUIDELINES
This manual contains information that relates to PROTECTING YOUR SAFETY and PREVENTING EQUIPMENT
PROBLEMS
and is very important for you to know and understand. We use the symbols below to help you
recognize this information.
DANGER - POTENTIAL HAZARD THAT WILL RESULT IN SERIOUS INJURY OR LOSS OF LIFE WARNING - POTENTIAL HAZARD THAT COULD RESULT IN SERIOUS INJURY OR LOSS OF LIFE CAUTION - POTENTIAL HAZARD THAT MAY RESUL T IN MODERATE INJURY OR DAMAGE TO EQUIPMENT
WARNING
1. RISK OF EXPLOSION OR FIRE.
Never spray flammable liquids in a confined area. It is normal for
the motor and pressure switch to produce sparks while operating. If sparks come into contact with vapors from gasoline or other solvents, they may ignite an d cause a fire or explosion. DO NOT smoke while spraying. DO NOT spray where sparks or flame are present. Keep compressor as far from spray area as possible. Always operate the compressor in a well-ventilated area.
2. RISK OF ELECTRIC SHOCK. A licensed electrician in accordance with all local and national codes must install all wiring. To avoid electric shock, NEVER use an electric air compressor outdoor. when it is raining or on a wet surface.
3. RISK OF BURSTING. Rust can weaken the tank.Drain the condensed water from the tank after each use to reduce rusting. DO NOT weld, drill or modify the air tank of this compressor.Welding or modifications on the air tank can severely impair tank strength and cause an extremely hazardous condition. If a leak detected in the tank, replace the tank right away.
4. RISK OF INJURY. ALWAYS shut off the compressor, remove the plug from the outlet and bleed all pressure from the system before servicing the compressor or when the compressor is not in use. DO NOT use the unit with the shrouds removed. Contact with moving parts could cause serious injury.
5. RISK OF BURSTING. Check the maximum pressure rating in the manual or the serial tag label. Compressor outlet pressur e must be reg ulated s o as to n ever exc eed th e maxim um pressur e rating. Relieve all pressure through the hose before removing or attaching accessories.
6. RISK OF BURSTING. DO NOT adjust the pressure switch or relief valve for any reason. They have been preset at the factory for the maximum pressure of this un it. If the pressure switch or the relief valve are tampered with, personal injury or property damage may occur.
7. RISK OF BURNS. Pump and manifold generate high temperature. To avoid burns or other injuries, DO NOT touch the pump, manifold or transfer tube while the unit is running. Allow the parts to cool before handling or servicing. Keep children away from the compressor at all times.
8. RISK TO BREATHING. Read all labels when you are spraying paints or toxic materials, and follow the safety instructions. Use a respirator mask if there is a chance of inhaling anything you are spraying. NEVER directly inhale the compressed air produced by a compressor.
9. RISK OF EYE INJURY. ALWAYS wear ANSI Z87.1 approved safety goggles when using an air compressor. NEVER point nozzle or sprayer toward a person or any part of the bod y. If the spray penetrates the skin, serious injury may occur.
CAUTION
1. Pull the pressure relief valve ring daily to ensure that the valve is functioning properly.
2. The unit must be kept a minimum of 12 inches from the nearest wall, in a well-ventilated area for cooling.
3. Protect the air hose and electric cord from damage and puncture. Inspect them weekly for weak or worn spots and replace if necessary.
4. Always wear hearing protection when using an air compressor. Failure to do so may result in hearing loss.
5. Operation of the unit should always be in a position that is stable. Never use the unit on an elevated position that could allow the unit to fall or be tipped over.
- 3-
C
D
E
I
A
BASIC COMPRESSOR FEATURES
B
K
G
J
- 4-
A--------ELECTRIC MOTOR B--------AIR COMPRESSOR PUMP C--------PRESSURE SWITCH D--------PRESSURE RELIEF VALVE E--------AIR PRESSURE REGULATOR F--------TANK PRESSURE GAUGE G--------REGULATED PRESSURE GAUGE H--------AIR LINE OUTLET I---------AIR T ANK DRAIN V A LVE(invisible) J---------AIR T ANK K--------POWER CORD
F
H
BASIC COMPRESSOR FEATURES
A. ELECTRIC MOTOR: The motor is used to power the pump. It contains a thermal overload protector
and an automatic reset. If the motor overheats for any reason, the thermal overload protector will shut it down to prevent the motor from being damaged. The motor will automatically restart when it completely cools.
B. AIR COMPRESSOR PUMP: The pump is used to compress the air and discharge it into the tank via
the piston moving up and down in the cylinder.
C. PRESSURE SWITCH: The switch is used to start or stop the air compressor and is operated manually.
When in ON position, it allows the motor to start when the air tank pressure is below the factory set cut-in pressure and allows the motor to stop when the air tank pressure reaches the factory set cut-out pressure. ALWAYS set this switch to OFF when the unit is not being used, and before unplugging the unit.
D. PRESSURE RELIEF VALVE: The valve is used to prevent system failures by relieving pressure from
the system. When the pressure reaches the preset level, the pressure switch will not shut down the motor. It will aut omatically pop open or you can pull the ring on the valve to open.
E. AIR PRESSURE REGULATOR: The regulator is used to adjust line pressure to the tool you are using.
Turn the knob clockwise to increase pressure and counterclockwise to decrease pressure.
WARNINGNever exceed the maximum working pressure of the tool.
F. TANK PRESSURE GAUGE: The gauge is used to measure the stored air pressure level of the tank. It
is not adjustable by the operator, and does not indicate line pressure.
G. REGULATED PRESSURE GAUGE: The gauge is used to measure the regulated outlet pressure. H. AIR LINE OUTLET: The outlet is used to connect 1/4” NPT air hose. I. AIR T ANK DRAIN VALVE: The drain valve is used to remove moisture from the air tank after the unit is
shut off.
WARNINGNever attempt to open the drain valve when the tank pressure is over 10 PSI.
J. AIR TANK: The tank is used to store the compressed air. K. POWER CORD: This product is for use on a nominal 120 volt circuit an d should be grounded. A cord
with a grounding plug as illustrated must be used. Make sure that the product is connected to an outlet having the same configuration as the plug (see Figure 1). No adapter should be used with this product.
Check with a licensed electrician if the grounding instructions are not completely understood, or if in doubt as to whether the product is properly grounded. Do not modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a licensed electrician.
DANGERImproper installation of the grounding plug will result
in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat blade terminal. The grounding wire is in the green outer surface.
Grounded outlet
120V/15 A
Grounding Pin
Plug
- 5-
Figure1
ASSEMBLY
1. Unpack the air compressor and inspect the unit for damage and part s. If the unit has be en dam ag ed or some parts are missing, contact the Service Center immediately.
2. Check the serial tag label to ensure that it has the required pressure ratin g for its intended use.
3. Unpack the smaller plastic bag with the air filter included and have the air filter (A) assembled on the pump. (See Figure 2)
4. Locate the compressor a ccording to the following guidelines:
a. Set the compressor in a position near a
grounded electrical outlet.
b. The compressor must be at least 12 inches
away from any wall or obstruction and in a clean, well-ventilated area to ensure sufficient air flow and cooling.
c. The compressor must be level to ensure
proper drainage of the moisture in the tank.
d. In cold weather, store the compressor in a
heated building when not in use. This will reduce problems with the motor starting and freezing from water condensation.
5. Connect an air hose with a female connector fitting
kit to the compressor air line outlet.
A
- 6-
OPERATION
PRIMING THE PUMP
NOTE: The pump is shipped WITHOUT oil. Before starting, pour
in oil provided in the pump through the oil nozzle. The break-in oil should be changed after 8 hours of operation. To reduce maintenance and repair problems, use only premium compressor oil. SAE 10W-30 all weather air compressor oil is recommended for general use.
1. Check the oil level in the pump through the oil sight glass. The pump oil level must be between A1 and A2. Do not overfill or underfill. (See A)
2. Turn the pressure switch to the OFF position (See B)
3. Open the tank drain valve (See C). Turn counterclockwise.
4. Plug in the power cord
5. Turn the pressure switch to the ON position (See D). The unit will start. Allow the unit to run for half an hour to break in the internal parts. After half an hour, if the unit does not operate properly, shut down immediately and contact GreatNeck Service Center at 1-855-900-2653.
6. After half an hour, turn the pressure switch to the OFF position.
7. Close the tank drain valve. Turn clockwise.
8. Turn the pressure switch to the ON position. The unit will start and fill the tank to the cut-out pressure and stop.
NOTE: The pressure switch will restart the motor automatically as compressed air is used.
STARTUP
1. Before starting, check the oil sight glass to ensure that oil level in the pump is at the required level.
2. Turn the pressure switch to the OFF position.
3. Close the tank drain valve.
4. Plug in the power cord.
5. Turn the pressure switch to the ON position.
6. Adjust the pressure regulator to the working pressure of the tool. When adjusting from a higher to a lower pressure, turn the knob counterclockwise past the desired setting, then turn clockwise to reach the desired pressur e. DO NOT exceed operating pressure of the tool or accessory being used.
SHUTDOWN
1. Turn the pressure switch to the OFF position.
2. Unplug the power cord.
3. Reduce pressure in the tank through the outlet hose. You can also pull the relief valve ring and keep it open to relieve pressure in the tank. (See E)
CAUTION Escaping ai r a nd mo isture ca n pr opel de bris t hat
may cause eye injury. Wear safety goggles when opening drain valve.
B
C
A
D
E
CLOSE
OPEN
- 7-
ON
OFF
MAINTANCE CHART
WARNING To avoid personal injury, always shut off and unplug the unit and relieve all air pressure
from the system before performing any service on the air compressor.
Regular maintenance will ensure trouble free operation. The items listed in the chart should be inspected on a regular basis.
ITEM DESCRIPTION
SERVICE
INTERVAL
Drain the tank
To prevent corrosion inside the tank, the condensation must be drained at the end of every workday. Be sure to wear protective goggles. Relieve the air pressure in the system and open the drain v alv e on th e bottom of the tank.
Daily
Check the oil
Check the oil level in the pump through the oil sight glass. The pump oil level must be within the red circle. Do not overfill or underfill.
Daily
Check the relief valve
Pull the relief valve on the ring daily to ensure that it is operating properly and to clear the valve of any possible obstructions.
Daily
Clean the air filter
A dirty filter will reduce the unit’s performance and life. To avoid any contamination of the inside pump, th e filter should be cleaned frequently and replaced on a regular basis. Foam filter should be cleaned in warm and soapy water.
Weekly
Test for leakage
Check all connections to see if tight. A small leak of any part( the tank, hoses, pipe connections or transfer tubes) will reduce the unit’s performance. Spray a small amount of soapy water around the area of the suspected leak with a spray bottle. If bubbles appear, repair or replace the faulty component. Do not over tighten any connections.
N/A
Storage
Before storing the unit for a long period, use an air blow gun to clean all dust and debris from the compressor. Disconnect and coil the power cord up. Clean the filter element and filter housing. Drain all moisture from the tank. Pull the pressure relief valve to release all pressure from the tank. Cover the entire unit to protect it from moisture and dust.
N/A
- 8-
TROUBLESHOOTING CHART
NOTE: Troubleshooting problems may have similar causes and solutions.
PROBLEM POSSIBLE CAUSE SOLUTION
Motor will not run or start
Power cord not plugged in Plug cord into grounded outlet Pressure Switch in “OFF” position Turn switch to “ON” position Wrong gauge wire or length of
extension cord
Check chart on page 2 for proper gauge wire and cord length
Motor thermal overload switch tripped
Turn air compressor off, wait until motor is cool, then check motor circuit breaker
Fuse blown or circuit breaker tripped
-Replace fuse or reset circuit breaker
-Check for proper fus e amperage
-Check for low voltage conditions
-Disconnect any other electrical appliances from circuit or operate compressor on its branch circuit
Air tank pressure exceeds preset pressure switch limit
Motor will start automatically when tank pressure drops below tank cut-in pressure.
Check valve stuck open Remove and clean or replace Loose electrical connections Contact authorized service center Possible defective motor, capacitor
or check valve
Contact authorized service center
Motor runs continuously when in the Start/Stop option
Pressure switch does not shut off motor when air compressor reaches cut-out pressure and safety relief valve activates
Move the pressure switch to the OFF position. If the motor does not shut off, unplug the air compressor. If the electrical contacts are welded together, replace the pressure switch.
Air compressor not large enough Check air requirement of accessory used. If it is higher
than CFM and pressure supplied by compressor, a larger compressor is needed. Most accessories are rated at 25% of actual CFM while running continuously.
Regulator does not regulate pressure
Dirty or damage regulator internal parts.
Replace regulator.
Low pressure or not enough air
Fittings leak Check fittings with soapy water. Tighten or reseal
leaking fittings. But do not over tighten.
Tank drain valve is open Close drain valve Restricted air intake Clean or replace air filter element. Prolonged or excessive use of air Decrease amount of air used Hole in air hose Check and replace if necessary Tank leaks WARNING
Replace unit immediately. DO NOT attempt to repair.
Valve leaks Check and replace worn parts.
Moisture in discharge air
Condensation in air tank caused by high level of atmospheric humidity or air compressor did not run long enough.
Drain air tank after each use. Drain air tank more often in humid weather and use an air line filter.
Overheating
Poor ventilation Relocate compressor to an area with cool, dry and
well-circulated air.
Dirty cooling surfaces Clean all cooling surfaces of pump and motor
thoroughly.
Leaking valve Replace worn parts and reassemble with new seals.
- 9-
EXPLODED VIEW EXPLODED VIEW
PARTS LIST
ITEM QTY DESCRIPTION 1----------1----------- Drain Valve 2----------2----------- Pin 3----------2------------Wheel 4----------2------------Pad 5----------1------------Air Tank 6----------1------------Pressure Switch 7----------1------------Plastic Anchor 8----------1----------- Air Filter 9----------1-----------Oil fill plug 10--------1----------- Pump/Motor Assembly 11--------1----------- Elbow 12--------1------------Shroud 13--------2------------Washer 14--------2------------Screw 15--------1------------Power cord
ITEM QTY DESCRIPTION 16------------2------------Screw 17------------4----------- Bolt
18------------4------------Washer 19------------4------------Spring washer
20------------4------------Nut 21------------1------------Plastic Anchor 22------------1------------Tube Transfer 23------------1------------Check Valve 24------------1------------Tube, bleeder 25------------1------------Handle grip 26------------2------------Pressure gauge 27------------1------------Regulator 28------------1------------Quick coupler 29------------1------------Safety valve
- 10-
GreatNeckR Saw Manufacturers, Inc
1 year Limited Warranty
This warranty covers any defects in materials or workmanship of the enclosed product. GreatNeck Inc. will repair or replace any defective materials due to craftsmanship of the product. This warranty does not cover any problem caused by misuse, abuse, accidents or acts of God, such as floods or hurricanes. Consequential and incidental damages are not covered under this warranty. Coverage terminates if you sell or otherwise transfer the ownership. If you feel you have a defective product, please submit a copy of your receipt to the address below and call 1-855-900-2653 for instructions prior returning this item to the store or sending back to:
GreatNeck Saw Manufacturers, Inc 165 East 2nd Street, Mineola, NY 11501
We will inspect the product and contact you within 72 hours to give you the result s of our inspection. We reserve the right to rep air or replace the product at our discretion. However , we may replace the product with one of similar but not exact features. Parts and Service Information available call GreatNeck at 1-855-900-2653 This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
- 11-
Loading...