When installing and using this electrical equipment, basic safety precautions should always be
followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
WARNING - RISK OF ELECTRIC SHOCK - The pump cannot be using while
people are inside the pool.
WARNING - TO REDUCE THE RISK OF INJURY, do not permit children to use this
product unless they are closely supervised at all times.
WARNING - RISK OF ELECTRIC SHOCK. Connect only to a grounding type
receptacle. This product is provided with a ground-fault circuit-interrupter. If replacement of the
plug is needed, use only identical replacement parts.
WARNING: The unit is provided with a ground-fault circuit-interrupter (GFCI). To test
the GFCI, push the test button. The GFCI should interrupt power. Push the reset button.
Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If
the GFCI interrupts power to the pump without the test button being pushed, a ground current
is flowing, indicating the possibility of an electric shock. Do not use this pump. Disconnect the
pump and have the problem corrected by a qualified service representative before using.
CAUTION- To reduce the risk of electric shock the pool must be installed no closer
than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances closer than 5
feet (1.5 m) from the pool.
WARNING: The pump is not intended to be bonded to the equipotential bonding
grid.
DO NOT BURY CORD. Locate cord to minimize abuse from lawn mowers, hedge trimmers,
and other equipment.
WARNING - To reduce the risk of electric shock, IF FILTER PUMP POWER CORD
BECOMES DAMAGED IN ANY WAY, THE PUMP MUST BE DISCARDED.
WARNING - To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
CAUTION - This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of being readily
disassembled for storage and reassembled to its original integrity. A permanently-installed
pool is constructed in or on the ground or in a building such that it cannot be readily
disassembled for storage.
CAUTION - For continued protection against possible electric shock this unit is to be
mounted to the base in accordance with the installation instructions.
IMPORTANT - Using the pump with an unmatched electrical supply is dangerous
and will result in catastrophic failure of pump.
RISK OF ELECTRIC SHOCK - When working with electricity, turn the electrical power off at
the circuit breaker and lock breaker door. Failure to do so will result in increased risk of shock,
injury and possibly death.
2
S-S-005774
Page 3
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY. DO
NOT USE ADAPTOR PLUGS. Consult a qualified electrician for any questions related to the
validity of your plugs grounding. Handle the pump with care. Do not pull or carry the pump by
the power cord. Never pull a plug from the outlet by yanking the power cord. Keep cord free
from abrasions. Sharp objects, oil, moving parts, and heat should never be exposed to the
filter pump.
NOTE: Please examine equipment before use. Notify Bestway at the customer service
address listed on this manual for any manufacturing defect or missing parts at the time of
purchase. Verify that the equipment components represent the filter pump model that you had
intended to purchase.
NOTE: Place pump on a solid and level ground. Pay attention to position of pool and
pump so adequate ventilation, drainage, and access for cleaning is available. Never place
pump in an area that may accumulate water, or in an area where foot traffic will flow around
the pool.
NOTE: Atmospheric conditions may affect the performance and life span of your filter
pump. Unnecessary wear and tear may occur during periods of cold, heat and exposure to
sun. Whenever possible shelter the pump from these conditions.
NOTE: Do not add chemicals in the filter pump.
NOTE: Assembly and disassembly of this product should only be performed by adults.
• THERMALLY PROTECTED MOTOR CSA ENCLOSURE 3.
• FOR USE WITH SWIMMING POOLS ONLY.
• CAUTION:TO ENSURE CONTINUED PROTECTION AGAINST SHOCK HAZARD,
USE ONLY IDENTICAL
REPLACEMENT PARTS WHEN SERVICING.
• WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A GROUNDING
TYPE RECEPTACLE.
• CAUTION:THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY - DO NOT
USE WITH PERMANENTLY-INSTALLED POOLS.
• CAUTION:CONNECT ONLY TO GROUNDING TYPE RECEPTACLE PROTECTED
BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
• CAUTION:FOR CONTINUED PROTECTION AGAINST POSSIBLE ELECTRIC
SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN ACCORDANCE WITH THE
INSTALLATION INSTRUCTIONS.
• WARNING - RISK OF ELECTROCUTION
1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin.
2) Inspect Cord Before Using – Do Not Use If Cord Is Damaged.
3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground.
4) Do Not Touch Plug With Wet Hands.
5) Double Insulated – When Servicing Use Only Identical Replacement Parts.
1) Open/unscrew the Air Purge Valve (P6112) on the top of the Filter Pump; air is released as
water fills the Filter Pump.
2) When water comes out of the Air Purge Valve (P6112) screw it closed and wipe away any
water.
NOTE: You must
clean the filter cartridge every day
and open the top valve let the air out then
close it before using the pump, otherwise the pump may not work.
250
390
163
2-M8 nut
390
163
2-M8 bolt
Fig.1
PEDESTAL FIXING Fig.1
EN60335-2-41 TEST standard requires the filter pump must be vertically fixed on ground or a certain pedestal made of wood or
concrete before use. There should be two holes 9mm in diameter on the pedestal, the space between which should be 163mm. Put
filter pump on the pedestal and fix them together by fasten the bolts and nuts. All the pedestal parts should weigh over 18kgs at least
to prevent the pump from accidental falling.
5
S-S-005774
Page 6
GFCI Test
ABC
RESET
RESET
D
RESET
TEST
A. To test the GFCI plug, insert it into a grounding type receptacle.
B. Press the “RESET” button; the indicator turns red.
NOTE:
C. Press the “TEST” button. The indicator turns off.
NOTE:
D. Press the “RESET” button, the indicator light turns red, and the filter pump is ready for use.
WARNING:
If the indicator light is not on, the test has failed.
If the indicator light is not off, the test has failed.
RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE EACH
TEST
TEST
USE.
WARNING:
DO NOT USE THE PUMP IF THE ABOVE TEST FAILS.
Please contact your
local Coleman Aftersales Service.
NOTE:
To prevent the risk of electrical shock, ensure your hands are completely dry when
plugging-in the Filter Pump.
IMPORTANT:DO NOT DRY RUN THE FILTER PUMP - Make sure both the pool’s
Inlet and Outlet valves are fully covered by water before operating the Filter Pump.
PUMP MAINTENANCE
CAUTION:
MAINTENANCE OR STORAGE BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS.
1) Unplug the Filter Pump.
2) Stop water flowing to the Filter Pump refer to pool’s manual.
3) Unscrew the Filter Cap Retainer and remove the Filter Cap.
4) Clean the Filter Cartridge with a garden hose.If filter cartridge remains soiled or discolored, it is necessary to replace it with a new one.
5) Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
6) Check that the Filter Cap Seal is in place.
7) Replace the Filter Cap and screw the Filter Cap Retainer into position.
8) Open the Valve A and B.
9) Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use.
IMPORTANT:
For sanitary reasons we suggest replacing the Filter Cartridge with a new one every two weeks.
PUMP STORAGE
1) Unplug the Filter Pump.
2) Stop water flowing into the Filter Pump and to remove the Filter Cartridge.
3) Discard the Filter Cartridge.
4) Detach all Hoses.
5) Dry all components thoroughly.
6) Store the filter pump in a dry location out of the reach of children.Storage temperature: 4-40 ºC (39.2-104F)
7) Drain the pool according to the Pool Owner’s Manual.
PUMP WARRANTY
For information concerning pump warranty please visit our website at: www.bestwaycorp.com
YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY
To ensure pool water stays clean, please clean the filter cartridge every day.
6
S-S-005774
Page 7
T
I
E
M
I
D
L
•
•
360 DAYS ON PUMP
•
W
The product you have purchased comes with a limited warranty from the manufacturer Bestway®.
Bestway® stands behind our quality guarantee and assures, through a replacement warranty, your product will be free from manufacturer’s
defects.
The limited warranty is valid as follows:
360 days for the motor pumps, 30 days for hoses, fitting and accessory included in the package, all from the original date of
purchase.
To file a warranty claim, please contact your Bestway® After Sales Center at 1-855-838-3888 before sending any documents. They will
provide full instructions of what is needed for your claim. Bestway® is not responsible for economic loss due to water or chemical costs and
will not replace any products deemed to have been neglected or used outside of the owner’s manual guidelines. Bestway’s warranty covers
manufacturing defects discovered while unpacking the product or during use, as recommended within the user manual. This warranty applies
only to products that have not been modified by any 3rd parties. The product must be stored and handled in accordance with the technical
recommendations.
The warranty does not cover damages caused by misuse, abuse, neglect, including but not limited to: collision, fire, excessive heat exposure,
improper use of chemicals, exposure to extreme weather conditions, improper installation, or improper storage.
Replacements and repairs don’t extend the duration of warranty. The warranty start date is the date of sale shown on the original
receipt/ purchase invoice.
•
Y
T
A
N
R
R
A
Please copy the Batch Number found on the body of the filter pump.
Batch Number
BATCH NUMBER:
TO: Bestway® Service Department
Website: www.bestwaycorp.com
Toll-Free:1-855-838-3888
Please provide your address details in full.
Note: Incomplete address details will result in delayed shipments.
Bsetway® reserves the right to charge for redelivery of undelivered packages where the recipient is at fault.
Batch Number
Date of purchase:
Date:
Customer Code Number:
Batch Number
REQUIRED INFORMATION - PLEASE WRITE THE SHIPPING ADDRESS
Name:
City:
Address:
Country / State:
Zip code:Retailer:
Mobile:
Fax:
Telephone:
E-mail:
Please Clearly Write Your Item Code:
POOL FILTER PUMP
MODEL
#XXXXX
Item Code
IMPORTANT: ONLY THE DAMAGED PART WILL BE REPLACED, NOT THE COMPLETE SET.
Bestway® reserves the right to request photographic evidence of defective parts, or to require sending the item for additional testing.
In order to best assist you, we request all information you provided to be complete.
FOR FAQ, MANUALS, VIDEOS OR SPARE PARTS, PLEASE VISIT OUR WEBSITE: www.bestwaycorp.com
VIDEOS ARE ALSO AVAILABLE ON OUR BESTWAY CHANNEL ON YOUTUBE: www.youtube.com/user/BestwayService