Coleman 36ECMII Installation Instructions Manual

y
r
r
36ECMII
36” Circulating Louvered Firebox
Includes: Manual Variable Control Fan S Air Kit and Bi-Fold Doors with Brushed Brass finish
INSTALLATION INSTRUCTIONS
SAVE THIS BOOK
stem, Combustion
WARNING: ALWAYS LEAVE GLASS
DOORS FULLY OPENED OR FULLY CLOSED WHEN OPERATING THIS FIREPLACE.
This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21.60, Z21.84 o RGA 2-72 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. A vent-free log can only be installed in an aftermarket (completion of sale, not for purpose of resale from the manufacturer), permanently located, manufactured (mobile) home, where not prohibited by local codes. A DESA hood must be installed when using a vent-free gas log heater (see Accessories, p. 11)
This firebox meets the construction and safety standards of H.U.D. fo application in mobile homes when installed according to these instructions.
ALL DIMENSIONS IN THIS MANUAL ARE IN INCHES UNLESS OTHERWISE SPECIFIED
DESA INTERNATIONAL
2701 INDUSTRIAL DRIVE PN 54024 P.O. BOX 90024 REV F BOWLING GREEN, KY 42102-9004 6/02 www.desatech.com
CONTENTS
1. INTRODUCTION --------------------------------------------------------------------------------- PG. 2
2. SELECTING LOCATION --------------------------------------------------------------------------------- PG. 2
3. MINIMUM CLEARANCES --------------------------------------------------------------------------------- PG. 2
4. FRAMING AND INSTALLING --------------------------------------------------------------------------------- PG. 3
5. HEARTH EXTENSION --------------------------------------------------------------------------------- PG. 3
6. OUTSIDE AIR KIT INSTALLATION --------------------------------------------------------------------------------- PG. 4
7. FAN KIT ASSEMBLY --------------------------------------------------------------------------------- PG. 4
8. CHIMNEY PIPE INSTALLATION --------------------------------------------------------------------------------- PG. 4,5,6
9. TERMINATIONS --------------------------------------------------------------------------------- PG. 6
10. FINISHING YOUR FIREPLACE --------------------------------------------------------------------------------- PG. 7
11. MANTELS --------------------------------------------------------------------------------- PG. 7
12. GLASS DOORS --------------------------------------------------------------------------------- PG. 7
13. GAS LINE INSTALLATIONS --------------------------------------------------------------------------------- PG. 8
14. CHIMNEY OFFSET --------------------------------------------------------------------------------- PG. 9
15. DAMPER OPERATION --------------------------------------------------------------------------------- PG. 10
16. TECHNICAL SERVICE --------------------------------------------------------------------------------- PG. 10
17. REPLACEMENT PARTS AND ACCESSORIES --------------------------------------------------------------------------------- PG. 11
1
r
d
n
N
R
R
R
FOR YOUR SAFETY
Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any othe appliance.
Due to high temperatures, the appliance should be located out of traffic and away from furniture an draperies.
Do not place clothing or other flammable materials o or near the appliance.
EVER leave children unattended when a fire is
burning in the fireplace.
WARNING: IMPROPER INSTALLATION, ADJUST­MENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY, PROPERTY DAMAGE, O LOSS OF LIFE. REFER TO THIS MANUAL FO ASSISTANCE OR ADDITIONAL INFORMATION. CONSULT A QUALIFIED INSTALLER OR LOCAL DISTRIBUTOR.
CHECK HUD REQUIREMENTS BEFORE INSTALLING THIS FIREPLACE.
INTRODUCTION
Model 36ECMII is specifically designed for use in manufactured mobile homes. This fireplace includes a manual control fan system, combustion air kit and bi-fold doors with a brushed brass finish.
BEFORE YOU BEGIN
Before beginning the installation of the fireplace, read
these instructions through, completely.
These DESA components and fireplace are safe when
installed according to this Installation Manual. Unless you use DESA components, which has been designed and tested for the fireplace system, you may cause a fire hazard.
The DESA warranty will be voided by and DESA
disclaims any responsibility for the following actions:
a) Modification of the fireplace, components, doors, blower,
fans, air inlet system and damper control.
b) Use of any component part not manufactured or approved
by DESA in combination with a DESA fireplace system.
PROPER INSTALLATION is the most important step in ensuring safe and continuous operation of the fireplace. Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces. Although grounding may not be required by code the manufacturer recommends it.
This model fireplace 36ECMII meets the construction and safety standards of HUD for application in mobile homes when installed according to these instructions.
WARNING: DO NOT INSTALL A FIREPLACE INSERT
IN THIS BOX UNLESS THE MANUFACTURER’S INSTRUCTIONS WITH THE INSERT SPECIFICALLY STATE THIS FIREPLACE HAS BEEN TESTED FO USE WITH THE INSERT.
This fireplace is intended to be used as a decorative appliance and is not intended to be used to heat the home.
This wood burning fireplace complies with the UL 127 standard as a FACTORY BUILT FIREPLACE and is listed and tested by
Underwriters Laboratories Inc.
CAUTION: The structural integrity of the mobile home floor, and ceiling/roof must be maintained.
SELECTING LOCATION
To determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines:
1. The location must allow for proper clearances (see figures 1 & 2).
2. Consider a location where the heat output would not be affected by drafts, air conditioning ducts, windows or doors.
3. A location that avoids the cutting of joists or roof rafters will make installation easier.
4. An outside air kit is included with this fireplace. For more details refer to section on outside air kit installation on page 4.
WARNING: DO NOT INSTALL IN A BEDROOM.
MINIMUM CLEARANCES TO COMBUSTIBLES:
Back and sides of fireplace …………………..1/2” Min.
Note: the ½” clearance is not required at the nailing flanges
Floor* ………………………….…………………0” Min.
*See step 2 of “Installing the Fireplace” – next page
Wall to front of Fireplace ……………………….36” Min.
Perpendicular Wall to Opening of Unit ………...14” Min.
Top Spacers …………………..…………………..0” Min.
Mantel Clearances …………………………… see page 7
“Finishing your Fireplace”
Chimney Outer Pipe Surfaces ……………………1” Min.
WARNING: DO NOT PACK REQUIRED AIR SPACES WITH
INSULATION OR OTHER MATERIALS.
MINIMUM/MAXIMUM CHIMNEY HEIGHT:
The MINIMUM height of the chimney, measured from the base of the fireplace to the flue gas outlet of the termination, is 11 feet for straight flue or a flue with one elbow set. The maximum distance between elbows is 2 feet. The maximum height of any system is 20 feet. This measurement includes the fireplace, chimney sections and the height of the termination assembly at the level of the flue gas outlet (see pg. 6, fig. 14).
2
FRAMING AND INSTALLING THE FIREPLACE
g
g
g
STEP 1: Frame the opening for the fireplace using the dimensions shown in figure 1 or 2. STEP 2: If the fireplace is to be installed directly on carpeting, tile (other than ceramic), or any combustible material other than wood flooring; the fireplace must be installed upon a metal or wood panel extending the full width and depth of the fireplace. STEP 3: Position the fireplace as shown in figure 4a by sliding the unit backward until the nailing straps on each side touches the side framing. STEP 4: Check the level of the fireplace and shim with sheet metal if necessary. STEP 5: Before securing fireplace to prepared framing, the ember protector (provided), must be placed between the hearth extension (not supplied), and under the bottom front edge of the fireplace to protect against glowing embers falling through. If the fireplace is to be installed on a raised platform, a Z-type ember protector (not supplied) must be fabricated to fit your required platform height. The ember protector should extend under the fireplace a minimum of 1-½”. The ember protector should be made of galvanized sheet metal (28ga. minimum) to prevent corrosion. STEP 6: Secure fireplace to floor using tie-down straps (see figure 4) to prevent shifting.
Figure 1 FRAMING DIMENSION
Fi
ure 2 CORNER INSTALLATION
HEARTH EXTENSION: (HE 36)
A hearth extension projecting a minimum of 16” in front of and a minimum of 8” beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fireplace. Use DESA hearth extension (see accessories on page 11) HE 36 or an equal material which meets the following specifications: a layer of non­combustible, inorganic material having a thermal conductivity of K=0.84 BTU IN/FT. HR. F (or less) at 1” thick. [For
example, if the material selected has a K factor of 0.25, such as glass fiber, the following formula would apply. 0.25/0.84 x
1.0” = 0.30 thickness required. Thermal conductivity “K” of
materials can be obtained from the manufacturer or supplier of the non-combustible material.] If the hearth extension is to be covered, use non-combustible material such as tile, slate, brick, concrete, metal, glass, marble, stone etc. Provide a means to prevent the hearth extension from shifting and seal the gap between the fireplace frame and hearth extension with a non-combustible material (see figure 3).
Fi
ure 3
WARNING: HEARTH EXTENSION IS TO BE
INSTALLED ONLY AS ILLUSTRATED.
Fi
ure 4
Figure 5
OUTSIDE AIR KIT (MODEL AK6E)
The installation of an outside air kit should be installed during the rough framing of the fireplace due to the nature of its location. Outside combustion air is accessed through the mobile home floor (Refer to AK-6 Installation Instructions for details). In some instances, a wall installation is required (see figure 5). Note: An AK6WE Air Kit must be ordered when a sidewall installation is required (see accessories on page 11).
3
Loading...
+ 9 hidden pages