T0022/FDN, T0022/FDH, T0032/FDN, T0032/FDH, T0056/FDN, T0056/FDH, T0082/FDN, T0082/FDH, T0082/XFDN, F0140/NDN, F0140/NDH, F0140/FDN, F0140/FDH, F0330/NDN, F0330/NDH, F0330/FDN, F0330/FDH, F0330/XFDN, F0720/NDN, F0720/NDH, F0720/FDN, F0720/FDH, F0760/NDN, F0760/NDH, F0760/FDN, F0915/NDN, F0915/NDH, F0915/FDN, F0915/FDH, F1340/NDN, F1340/NDH, F1640/NDN, F1640/NDH
Valid for all Coldtainer mobile fridges produced by Euroengel srl from May 2017 onwards
Copyright©2017 Euroengel srl
Coldtainer™ is a trademark by Euroengel srl
GENERAL 2
SAFETY 2
TECHNICAL NOTES 3
BEFORE USE 4
ELECTRICAL CONNECTIONS, STANDARD MODELS 4
DC
connectors, fridge side 5
dc cords 5
direct connection to a dc battery 5
optional - Use of the coldtainer connected to ac mains (100-240Vac 50/60 hz) 6
ELECTRICAL CONNECTIONS, “AUTONOMOUS OPERATION” MODELS
connection to ac mains (100-240Vac 50/60 hz)
6
OPERATION 7
control panel 7
electronic thermostat (eVco) 7
switch on the coldtainer 8
switch off the coldtainer 8
lock / Unlock the keypad 8
modify the setpoint 8
setting configUration parameters 8
enable temperatUre decimal point 9
change temperatUre Unit of measUre (°c or °f) 9
set a cabinet probe offset 9
set an high / low temperatUre alarm 9
BATTERY PROTECTION 10
SELF-DIAGNOSTIC 10
OPTIONAL – USE OF HACCP / BLUETOOTH MODULE
CLEANING AND MAINTENANCE 11
LIMITED LIABILITY 11
DISPOSAL 12
6
11
2
GENERAL
The
coldtainer
s has been designed for the professional temperature controlled transport of limited volumes of perishable items, like food, pharmaceuticals, biologicals. The units are designed, if properly operated and connected to a suitable power source, to maintain perishable items at a stable temperature during transport, as a link of a “cold chain” system. Units are not designed to cool down or freeze or heat up perishable items. The units are not intended for sale-to and use-by end consumers. The sales of Euroengel mobile fridges do not fall within the scope of Directive 1999/44/EC or similar end users protection legislations.
SAFETY
Before using the unit, read these operating instructions carefully, including all
information on operating safety, use and maintenance.
Keep these operating instructions ready at hand and leave them with the unit,
so that all users can nd out about the functions and safety regulations. Every
user must be well acquainted with the operation of the appliance and with the instructions concerning safety. Failure to observe these instructions can impair the performance of the appliance and cause damage.
All installation work and adjustments to the unit must only be carried out by
qualied personnel. Work performed by persons with insufcient technical
knowledge may adversely affect the performance of the unit or cause physical injury or damage to the equipment.
The unit must only be used by adults. Do not allow children to play with the
units or touch the controls.
Do not place inammable liquids or gas bottles in the cool box. Danger of
explosion!
For large containers: never lock anybody inside. Danger of suffocation!
Pay attention on all moving parts when closing the door. Watch out not to hurt
your hands or ngers when operating the closing mechanism.
Be aware of the full weight of the unit you are using. Use proper lifting
equipment in the case.
Before cleaning or carrying out maintenance work, always switch the refrigerator
off and disconnect the plug.
The unit’s hermetic cooling system contains CFC free refrigerant gas (R134a or
R404A). Make sure to not damage the cooling system so to avoid leaks.
3
TECHNICAL NOTES
Specic versions with different internal temperature setting are available for each container size, (ask for data sheet of single models for specic values):
NDN: cooling function, internal temperature down to 0°C (with +32°C ambient)
NDH: automatic cooling / heating function, internal temperature from 0°C to +30°C (with ambient temperature from -20°C to +32°C)
NDH: automatic cooling / heating function, internal temperature from 0°C to
+30°C (with ambient temperature from -20°C to +32°C)
FDN: freezer function, internal temperature down to -21°C (with +32°C ambient)
FDH: automatic cooling / heating function, internal temperature from -21°C to
+30°C (with ambient temperature from -20°C to +32°C)
XFDN: deep freezing, internal temperature down to -30°C or -35°C, according
to model (with +32°C ambient)
The
coldtainer
s operate via direct current compressors connected to a 12-24Vdc or 12Vdc power source (according to model). The high quality SECOP BD series direct current compressors used in the units are designed to withstand vibrations, also in case of use in off-road conditions, and can work with an inclination of up than 30°.The units shall be switched off if positioned at an angle of more than 30°.
After being returned to a level position, allow to rest for approximately 30 minutes
before switching on. SECOP compressors have built-in protection systems against overload and start
failure, fan overload, reverse polarity, overheating. When overload protection is activated, the compressor enters a cycle in which it attempts to start at approximately 60 second intervals until a successful start is achieved. When overheating protection is activated (i.e. ambient temperature exceed ab. +55°C) the compressor will restart automatically approximately 60 seconds after the temperature of the electronic has
cooled down to a safe value.
If a voltage outside the specied range is applied to the electronic unit, the compressor does not start, or it stops if the voltage limit is exceeded during operation. The compressor will restart automatically approximately 60 seconds
after the supply voltage has reached the reset voltage within the range in question. If a fan is installed, it will start to operate without a delay as soon as the reset voltage is reached.
Maximum operating ambient temperature is ab. +55°C (with degraded
performances). Minimum operating ambient temperature (for NDH and FDH models) is -20°C. The internal temperature displayed by the digital controller is the one sensed in the vicinity of the probe area. The temperature in other points of the container can vary, after stabilization, normally in a ± 2°C range. The NDH and FDH versions have an internal fan for a better internal air distribution. An “internal fan” kit is available as accessory for the NDN, FDN and XFDN versions. Always pre-condition the internal temperature of the unit before use. Do not place