Coemar Panorama Power MK2 Instruction Manual

manuale di istruzioni
instructions manual
Version 1.0
Panorama
Power
MK2
A
B
C
D
E
F
760 mm
29,92”
max 720mm
28,35”
540mm
21,26”
430mm
16,93”
max 830mm
32,68”
460mm
18,11”
max 650mm
25,60”
590mm
23,23”
A
B
cod. 9821
333mm
13.11”
460mm
18.11”
13mm
0.51”
90mm
3.67”
360mm
14.17”
279mm
10.98”
15° Max 15° Max
15° Max 15° Max 15° Max
15° Max
15° Max 15° Max
OK NO NOOK
-35°
75°
D
C
B
A
60Hz
230V
208V
50Hz
240V
factory set main at:
0100115 208 230 240
24 0
1615
39 48
32
208V 230V 240V
60Hz 50Hz
208V 230V 240V
60Hz 50Hz
43
34
49
ground
neutral
live
brown
blue
yellow/green
main
60Hz
alto/top
5 pin XLR 5/M
3 pin XLR 3/F
in
out
out
in
Controller DMX 512
OUT
3
2
1
Ad altri Panorama Power MK2
Connect to other Panorama Power MK2
60Hz
alto/top
60Hz
alto/top
channel function type of control effect
step closed 0 - 7
0% - 3%
proportional from close to open 8 - 2 55
3% - 100%
2 cyan proportional
proportional cyan control from white to cyan
0-255
0%-100%
3 magenta proportional
proportional magenta control from white to magenta
0-255
0%-100%
4 yellow proportional
proportional yellow control from white to yellow
0-255
0%-100%
park, no function 0 - 10
0%-4%
right lamp off 11 - 29
4%-11%
park, no function 30 - 140
12%-55%
right lamp on 14 1 - 255
55%-100%
park, no function 0 - 10
0%-4%
left lamp off 11 - 29
4%-11%
cmy reset (once only) 30 - 13 5
12%-53%
cmy and dimmer reset (once only) 13 6 - 17 0
53%-67%
park, no function 17 1 - 24 0
67%-94%
left lamp on 24 1 - 255
95%-100%
decimal
percentage
1
dimmer
5
right lamp on-off
step
6
left lamp on-off and
motors reset
step
Note 1: back panel can inhibit lamp off function.
Note 2: lamp on-off and motors reset functions has a delay time of 6 second to prevent accidental activation.
Note 3: on/off lamp mode is not affected unless an opposite value is received.
AOO1
MODE
+o --
+o --
menu
enter
+o --
+o --
--SL--
-- MA--
DMX
DMIN
VOLT
RATE
ALRM
HOUR
+o --
+o --
+o --
+o --
enter
MEAS
FUNC
LAMP
enter
FANS
+o --
DISP
+o --
LED
+o --
RESE
+o --
OFSE
+o --
TEST
+o --
DIMM
+o --
COLR
+o --
ID
+o --
Press together enter and menu keys
for 10 seconds: the display will show
alignement functions menu
A023
new DMX address
+o
A023 DMX address 23
Select new DMX address
enter
AOO1
MODE
menu
enter
+o --
+o --
enter
--SL-- slave function
Slave unit
--SL--
enter
-- MA-- master function
Master unit
PRG.1
Example
program 1
enter
PROGprogram
To select the number of program to run
+o --
+o --
+o --
P ALL
all programs
PRG4
to program
PRG1
from program
enter
enter
enter
enter
WAIT waiting time
Waiting times among memories (sec)
0.1
from number
0460
to number
+o --
enter
enter
enter
DMX DMX function
DMX function mode
enter
AOO1
+o --
SPEE speed
Memories running time (sec)
+o --
enter
0.1
from number
0120
to number
enter
enter
DMIN DMX value on each channel
Reading of DMX value (0/255), received by each of the 6 channels on DMX512 line.
CH01
from channel 1
CH06
to channel 6
enter
enter
enter
+o --
10
DMX value reading
255
DMX value reading
30.0V
voltage measurament
VOLT main voltage
To measures the DC main voltage in volt. You must consider normal the values between 26V and 36 V.
enter
RATE DMX rate
Reading of DMX512 signal value
enter
24
value reading
NDMX
no dmx signal
ALRMalarm
Reading of warning message sequences (errors) shown after reset operation.
enter
NO.AL
no alarm
ADER
warning message
10
value reading
HOUR Working time
Working time (hour)
enter
+o --
LIFE
Visualisation of lamp life (time covered by
mains supply from last
reset operation)
LIFS
Life of all lamps
used on the unit
enter
+o --
enter
enter
10
value reading
1230
value reading
enter
+o --
enter
enter
enter
UNIT
Projector life
LEFT
left lamp
LEFT
left lamps
2340
value reading
+o --
RIGH
right lamp
RIGH
right lamps
menu
AOO1
MEAS
+o --
+o --
+o --
+o --
enter
oppure
oppure
1230
value reading
menu
AOO1
FUNC
STRD
standard speed
FAST
high speed
SLOU
low speed
D IMM dimmer speed
Mechanical dimmer operating time speed on DMX signal variation. (selection between standard and slow)
enter
+o --
+o --
enter
enter
enter
STRD
standard speed
FAST
high speed
SLOU
low speed
COLR colour changer speed
Colour changing system operating time speed on DMX signal variation (selection between standard and slow).
enter
+o --
+o --
enter
enter
enter
FANS fans control
Fan status control through PCB (Strd) or fans always on (On).
STRD
automatic control
ON
fan always ON
+o --
enter
LAMP switching on control
To disable on/off control of the lamps by DMX signal
STRD
switching on throught DMX512
ON
lamps always on
STRD
switching on throught DMX512
ON
lamp always on
STRD
switching on throught DMX512
ON
lamp always on
ALL
all the lamps
LEFT
left lamps
RIGH
right lamps
enter
enter
enter
+o --
+o --
enter
+o --
+o --
enter
enter
enter
enter
enter
AA
base downwards
reversed, base upwards
AA
DISP reverse display
Reverse reading display depending on mounting position(ground mounted or suspended)
enter
+o --
enter
enter
LED display control
To disable display visualisation
ON
display actived
AUTO
display switch off after 6 second
(press any key to re-activate it)
enter
enter
enter
enter
ID ID number setting
To set the unit’s ID number from 1 to 250
1--250
numeric value
enter
DFSE default function setting
To set all the functions at the original values, but for the alignement operations.
enter
enter
SURE
TESTtest function
Device operation test without DMX signal
0127
enter
enter
enter
0127
enter
enter
0127
enter
enter
0127
enter
enter
enter
+o --
+o --
+o --
+o --
0020
SURE
0020
0020
0020
es.
+o --
enter
es.
+o --
es.
+o --
es.
+o --
+o --
+o --
enter
enter
enter
+o --
enter
+o --
+o --
+o --
+o --
+o --
+o --
+o --
RESE reset
Reset function
-– -– -– -–
reset activation
enter
+o --
DIMM
dimmer activation
CYAN
cyan activation
MAG
magenta activation
YELL
yellow activation
STOR
to record the position of the unit and of its internal
components. If DMX signal is not applied, the recorded
setting will appear at the end of reset operation when
the unit is switched on.
Press together enter and menu keys for 10 seconds: the display will show
alignement functions menu
(see section 11.4. Electronic motor alignment)
menu
MODE MEAS
AOO1
FUNC
+o --
+o --
enter
ID ID number setting
To set the unit’s ID number from 1 to 250
1--250
numeric value
enter
+o --
enter
in
out
out
in
Ad altri Panorama Power MK2 slave
Connect to other Panorama Power MK2 slave
60Hz
alto/top
60Hz
alto/top
MASTER
SLAVE
R
e
m
o
v
e
t
o
r
e
-
l
a
m
p
R
e
m
o
v
e
t
o
r
e
-
l
a
m
p
DIMM dimmer
Dimmer alignment
CYANcyan
Cyan colour alignment
MAG magenta
Magenta colour alignment
YELL yellow
Yellow colour alignment
CL L lamp hour meter reset
To reset the hour meter of left lamp. The operation is made every lamp change.
CL R lamp hour meter reset
To reset the hour meter of left lamp. The operation is made every lamp change.
END end
To end the electronic setting procedure and confirm the recording.
enter
enter
enter
enter
enter
SURE
confirm reset
0128
0128
0128
0128
+o --
+o --
+o --
+o --
0128
0120
0165
0138
es.
es.
es.
es.
enter
enter
enter
enter
+o --
+o --
+o --
+o --
+o --
SURE
confirm reset
enter
+o --
A001
enter
+o --
Press together enter and menu keys for
10 seconds: the display will show this menu
RESE
AOO1
+o --
FUNC
+o --
menu
Loading...