![](/html/e0/e084/e084241feda1e5b93f541e604213e1170113f16cd2f3949e02519dcd73b124d9/bg1.png)
CL4500 Installation Instructions
Box Contents
Check the contents of the box are correct
according to the model
4510 4520
1 Front Plate
2 Back Plate
3 Lever Handles
4 Gaskets
5 Sprung Spindle (x1)
6
Spring Spindle (x3) 15/26/60mm ( / ”/ / ”/ 2 / ”)
1211323
8
7 1.5vAA Batteries (x4)
8 Mortice Latch, Strike and 4 screws
9 Fixing Bolts x 3 incl. spare
10 Latch Support Post
11 Allen Keys
12 Euro profile cylinder escutcheons (x2)
13 Double euro profile cylinder & 3 keys
14 Cable Connections for REM1 and REM2
15 Front Plate Cylinder Keys
16 Front Plate Cylinder Cover
17 Classroom Function Tailpiece
18 Mortice Lock
This box should also contain the installation template and getting started guide.
Tools Required
Power Drill
Drill bits CL4510 10mm ( / ”) & 25mm (1”)
3
8
Drill bits CL4520 10mm ( / ”), 12mm ( / ”), 16mm ( / ”) & 20mm ( / ”)
3
8
15
32
5
8
25
32
Hammer / mallet
Philips screwdriver
Find more online at www.codelockssupport.com
Page 1
![](/html/e0/e084/e084241feda1e5b93f541e604213e1170113f16cd2f3949e02519dcd73b124d9/bg2.png)
Find more online at www.codelockssupport.com
Chisel 25mm (1")
Stanley knife
Adhesive tape, pencil, bradawl, tape measure
Pliers and hacksaw for cutting bolts
Operations Check
You should familiarise yourself with the operation of the lock and check that all the parts work properly.
Remove the battery cover from the back plate and install the 4 x AA cells supplied.
Connect the cables from the front plate and back plate. A BEEP should be heard when you do this. If no BEEP is heard then check that the
batteries are correctly installed.
Place the long spindle in the front plate socket and using finger grip only, test that the spindle is easily moved 80° in both directions.
Leave socket in the centred position.
Enter the factory Master Code #12345678.
The keypad will flash blue and the spindle should not turn as before. After 5 seconds the keypad will flash red and the spindle should turn
easily again. This confirms that the clutch engaged correctly when the code was entered
N.B. When the Master Code is entered 3 times consecutively without performing a programming function, a penalty time of 30 seconds is
activated.
Disconnect the cables.
Special Fixing Note
Remote Release Option
Cables are provided for the and terminals on the circuit board.REM 1 REM 2
REM 1 is for connection to a reception desk push button or a door intercom system. Pressing the button will cause the keypad to flash blue
on the lock and release the lock for the pre-set time.
REM 2 is for connection to the building alarm system to release a door in an emergency. This allows rooms, wards, offices to be easily
checked to ensure that no person is trapped or overlooked during an emergency evacuation. When activated will maintain theREM 2
unlocked condition for 30 minutes, the keypad will flash red and BEEP during this time. The lock will automatically lock again after 30
minutes. If necessary Program 7 can be used to re-lock before the end of the 30 minutes. and do not require additional power.REM 1 REM 2
They are normally open contacts requiring a momentary or maintained signal to close.
Page 2
![](/html/e0/e084/e084241feda1e5b93f541e604213e1170113f16cd2f3949e02519dcd73b124d9/bg3.png)
Find more online at www.codelockssupport.com
Functions
CL4510 Latch Function
Outside handle turns freely without operating the latchbolt. When the code is entered the keypad will flash blue and the handle will retract the
latchbolt. The latch automatically locks the door when closed. The key will open the door without the code.
CL4520 Anti-Panic Lock Function
Outside handle and key functions as before. Lock case key will double-throw the deadbolt, retract the deadbolt and retract the latchbolt
without the code. When deadbolt is thrown it denies access by code. The anti-panic feature allows the inside handle to simultaneously retract
the latchbolt and the deadbolt preventing people being accidentally locked in.
Installation of CL4510 Locks
Page 3