Code CODE-2641 Series User Manual

Page 1
Other Products In The Range
Code
Description
1 or 2 door controller with Ethernet connection
1 or 2 door controller with Serial connection
2 or 4 door controller with Ethernet connection
2 or 4 door controller with Serial connection
5 Amp Power supply in Metal Box Enclosure
Card Distributor
Mifare Card
CODE-6800
CODE-FC02
CODE-MF01
CODE-2641 Series
Vandal Resistant Reader
USER MANUAL
Page 2
A
For the reader cable connection to the CODE Controller, CAT 5 cable or 8 core twisted pair cable can be used.
B
The reader is normally installed at the right side of the door (outside) at a height of 1.4m from the floor and 3-5 cm from the door frame, with the exit button (inside) also at a height of 1.4m off the floor.
C
The reader should not be installed against a metal sur face. If this can not be avoided, either the metal surface should be removed, with only the fixing area remaining, or an isolation material thicker than 10cm should be placed between the reader and the metal surface.
D
The Controller to reader length should not exceed 60 metres using CAT 5 cable
E
Please observe reader power polarity when connecting to the access controller
Notes For Installation
Product Specification
Reader Parameters
Reader Radio Frequency: 13-56 MHz
Card Identification Mode: MF card
Sensing Distance: MF Card 2-4cm
Reader Data Output: Wiegand 26 Bit
Reading Speed: < 0.1s
Name Qty Note
CODE-2641 1 Vandal Reader
User manual 1 User Documentation
Screw driver 1 Φ20mm×60mm,Special for RF006
Rubber plug 2 Φ6mm×30 mm, used for fixing
Self tapping screws 2 Φ4mm×28 mm, used for fixing
Material Metal
Operating Voltage 9-16V DC
Output WG 26
Card type Mifare
Reading Distance 2-4 cm
Communication Distance 60M
Idle Current <80mA
Operating Temperature -45ºC ~ 60ºC
Operating Humidity 10%- 90% RH
Waterproof Conforms to IP68
Dimension 120X56X18 mm
Packing List
Specification
Page 3
Wiring Connections
Installation Procedure
LED
BEEPER
D0
D1
+12V
GND
Reader Wire
Blue
Yellow
Green
White
Red
Black
Connect with controller LED
Connect with controller beeper
WG output line D0
WG output line D1
Power supply +12V
Power supply GND
*Note
To activate the sounder during the operation of the LED changing to Green, connect the Yellow Buzzer wire to “BUZ” on the controller.
Colour
Controller Connection
STEP 1STEP 2
Remove the back cover from the keypad using the supplied special screw driver
Gently pull the metal back plate cover away from the main body of the reader.
• Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
• Put the supplied rubber bungs to into the two holes
• Fix the back cover firmly on the wall with 2 Self tapping screws
• Thread the cable through the cable hole, connect the wire needed, wrap unused wire with insulating tape isolated to prevent short circuit
• Attach the keypad to the back cover.
STEP 3
”BUZ” input on controller
Page 4
FAQ
What should I do?:
7.1
Card not recognised by reader
• Check whether the Data transmission connections of DATA 0 and DATA 1 are correct.
• Check that the distance between the controller and the reader is no longer than 60 metres (Wiegand 26 bit). If so, reduce the distance between the controller and the reader.
• Check the RD OK (Reader signal OK) LED ok goes green when an ID device is presented to the reader.
• Check the power on the reader power wires is within 10.5v DC and 12.5v DC.
7.2
If the lock does not operate.
• Check whether the connections of the readers, exit buttons and electric locks are wired correctly.
• Check if the output of the relay switches and the relay operation LED switches on.
• Check if the power is being switched to the lock.
• If there is no switching of the relay, then check the reader and the wiring.
• Check the access software programming.
7.3
If the Reader does not operate after a power down.
• Please perform a controller download from the CODE Access Software
Loading...