User Manual Coda® ECOTM 1200 V2 – October 18, 2017Page 2
Symbols
REF
SN
EC REP
Caution
Disposal of Device, if you wish to discard electrical and electronic
equipment, please contact your dealer or supplier for further information.
Alternating Current
Product Certication Authorized by BSI
Catalogue Number
Serial Number
Temperature Limitation
Humidity Limitation
Atmospheric Pressure Limitation
Canadian Standards Association
Consult Instructions For Use
RX OnlyBy Prescription Only
GS1 DataMatrix Barcode
Authorized Representative in the European Community
Manufacturer
M-CODA-1200
User Manual Coda® ECOTM 1200 V2 – October 18, 2017Page 3
General Information
Indication For Use: The Coda Air Purication System may be used as an accessory item during
assisted reproductive procedures.
Please familiarize yourself with this manual before using the device.
®
The Coda
improve health conditions for you, your employees, and your family.
Highlights
The Coda® ECOTM 1200 is a durable and an effective air purication unit.
Coda® ECOTM 1200 lter contains HEPA 99.97%, carbon and potassium permanganate to
The Coda® ECOTM 1200 lter should be changed at a minimum every 6 months.
Coda® ECOTM 1200 has a variable speed fan for your comfort.
Maximize and Support your Central Air Filter System
Most central air heating and air conditioning systems ‘dump’ larger levels of particulates and VOCs into
your space. This is due to inefcient lters and low ratings of lters.
ECOTM 1200 is a proven technology in IVF and ART to purify the air in your laboratory and
remove VOCs and CACs.
®
In our study we measured particulate levels of 7000 ppm. By installing a Coda
ECOTM 1200 you can
bring this level to less than 1500 ppm, a signicant reduction. The impact is cleaner air and better
health. This reduction is important because particulates may carry contaminants onto your samples
and into your space.
®
The Coda
ECOTM 1200 lter will capture more than 1000 harmful particulates, VOCs, CACs and
distributed completely or in part without the written consent of LifeGlobal Group, LLC.
Catalogue Numbers
Catalogue #s:GELT-115
Floor Coverage: sq. ft.
sq. m.
Room Volume: cu. ft.
cu. m.
Air exch. per hour
Size dXwXh: in
cm
Weight: pounds
kilograms
GELT-230
800 – 1800
74 – 167
6400 – 14400
185 – 417.5
8 – 27 times
13 x 18 x 54
33 x 46 x 137
120
54
4-stage lter system (4 Canisters)
Carbon & Potassium Permanganate Mix
kgs2411
Annual Kit
(Install with initial set-up of unit and
change 6 months after semi-annual kit.)
Semi-Annual Kit
(Change 6 months after annual kit.)
lbs
GEAK-1200
GESA-1200
M-CODA-1200
User Manual Coda® ECOTM 1200 V2 – October 18, 2017Page 4
Warning & Caution
Warning: To avoid risk of electrical shock, this equipment must only be connected to a supply mains
with protected earth.
Avertissement: Pour éviter tout risque de choc électrique, cet appareil doit être branché à une prise
de terre avec terre protégée.
CAUTION: Indicates a condition that may lead to equipment damage or malfunction.
ATTENTION: Indique une condition pouvant entraîner des dommages matériels ou des
dysfonctionnements.
Caution: No modication of this equipment is allowed.
Attention: Aucune modication de cet équipement n’est autorisée.
Caution: Do not place the unit in a damp area, in water or under an open window. This may cause
damage to the unit.
Attention: Ne pas placer l’appareil dans une zone humide, dans l’eau ou sous une fenêtre ouverte.
Cela peut causer des dommages à l’unité.
®
Caution: Damage to the Coda
ECOTM 1200 will occur if the unit is put in a damp area, in water or
under an open window. Do not operate the Coda® ECOTM 1200 if it appears to have been dropped or
damaged. Federal (U.S.A.) law restricts this device to sale, distribution, or use by or on the order of a
licensed medical practitioner.
Attention: Des dommages au Coda® ECOTM 1200 se produiront si l’appareil est mis dans une zone
humide, dans l’eau ou sous une fenêtre ouverte. N’utilisez pas le Coda® ECOTM 1200 s’il semble avoir
été tombé ou endommagé. Le droit fédéral (États-Unis) restreint la vente, la distribution ou l’utilisation
de ce dispositif par un médecin agréé ou sur son ordre.
Servicing the Coda® ECOTM 1200
All devices to be returned must be prepared as described below for the protection of the servicing
®
team and for safety during transport. Clean the surface of the Coda
the “Cleaning the Coda
®
ECOTM 1200” section. Place the unit in the original packaging. Enclose the
following information:
Contact Name; Telephone Number; Clinic Address; Description of the fault or service required and
proof of purchase.