Read the entire instruction manual
carefully and make sure that you fully
understand it before you use the
equipment. Keep the manual for future
reference.
Viktig information:
Läs hela bruksanvisningen noggrant och
försäkra dig om att du har förstått den
innan du använder utrustningen. Spara
bruksanvisningen för framtida bruk.
Viktig informasjon:
Les disse anvisningene nøye og forsikre
deg om at du forstår dem, før du tar
produktet i bruk. Ta vare på anvisningene
for seinere bruk.
Tärkeää tietoa:
Lue nämä ohjeet huolellisesti ja varmista
että olet ymmärtänyt ne, ennen kuin
alat käyttää laitetta. Säilytä ohjeet
myöhempää tarvetta varten.
Wichtiger Hinweis:
Vor Inbetriebnahme die komplette
Bedienungsanleitung sorgfältig
durchlesen und aufbewahren.
ENGLISHSVENSKANORSKSUOMIDEUTSCH
Art.noModel
40-8665 PAT-106
Ver. 20161020
Original instructions
Bruksanvisning i original
Originalbruksanvisning
Alkuperäinen käyttöohje
Original Bedienungsanleitung
2
½″ Air Impact Wrench
Art.no 40-8665 Model PAT-106
Please read theentire instruction manual before using theproduct and save it
for future reference. We reserve theright for any errors in text or images and any
necessary changes made to technical data. If you have any questions concerning
technical problems please contact our Customer Services.
Safety
Warning: Read theentire instruction manual before using theproduct and keep it for
future reference. Make sure that you have read and understood theinstruction manual
before using thetool. Failure to follow thesafety instructions could lead to serious
personal injuries.
Warning: Do not exceed therecommended working pressure, 6.3 bar (90 psi).
Too high apressure can cause theimpact wrench to explode which may result in
serious or fatal personal injuries.
a) Disconnect theimpact wrench from theair hose before changing sockets/
tools, before servicing it, and as soon as you have finished using it.
b) Always wear safety glasses and ear defenders when theimpact wrench is in use.
c) Do not wear loose-fitting clothing or jewellery. Keep hair, clothes and loose-
fitting gloves away from moving parts. Loose-fitting clothes, jewellery or long
hair could become caught in moving parts and result in serious injury.
d) Do not pull thetrigger whilst theair hose is being connected.
e) Only use tools and accessories designed for use with pneumatic/air powered
tools. WARNING: Only use impact sockets which are designed for use
with impact wrenches. Normal sockets designed for use with hand tools, worn
sockets or damaged sockets should never be used with animpact wrench.
f) Do not pull thetrigger before thesocket has securely mated with thenut
or bolt. The socket must grip thehead of thebolt or nut securely.
g) Before using thetool, make sure that all connections are tight and that
theair hose is not damaged in any way.
h) WARNING: Always disconnect theair hose from theimpact wrench before
attaching thesocket/accessory and before carrying out any maintenance.
i) Neither this tool nor its accessories must be modified in any way.
ENGLISH
3
Workplace hazards
a) Keep your work area clean and well-illuminated.
b) The most common causes of serious or fatal injury in theworkplace are related to
ENGLISH
slipping, tripping or falling. Watch out for hanging cables or hoses and slippery floors.
c) Keep afirm footing and good balance at all times.
d) Repetitive work movements, uncomfortable work postures and vibrating
tools can be harmful to hands and arms.
e) Exposure to high noise levels can cause permanent hearing loss. Always use
ear protection.
f) Avoid inhaling dust particles or contaminants which might be harmful to
your health.
g) Keep pets and bystanders out of thework area when thetool is being used.
h) This tool is not designed for use in explosive atmospheres and is not
insulated for contact with electric power sources.
Personal safety precautions
a) Pay attention to what you are doing and use common sense when using
pneumatic tools. Never use any hand tool, pneumatic or power tool if you are
tired or under theinfluence of drugs, alcohol or medication. One moment of
inattention while using apower tool may result in serious injury.
b) Wear protective clothing. Always wear safety glasses. Using protective
clothing such as dust masks, non-slip safety shoes, helmets and ear defenders
when needed decreases therisk of injury.
c) Avoid accidental starts. Never hold your finger on thetrigger when connecting
theair hose or changing asocket.
d) Do not overreach. Make sure you stand steady and well balanced at all times.
This will allow you to have more control in unexpected situations.
e) Wear suitable clothing. Do not wear loose-fitting clothing or jewellery.
Keep hair, clothes and gloves away from moving parts. Loose-fitting clothes,
jewellery or long hair could potentially become caught in any moving parts.
f) Dust extraction or collection equipment should be used whenever thework
environment contains large amounts of dust.
g) Hold theproduct by its insulated gripping surfaces whenever using thetool
where it could come in contact with hidden live wiring. Contact with live wires
will make themetal parts of thetool live and could shock theuser.
h) Avoid direct contact with accessories during use.
Projectile hazards
a) Parts of theworkpiece, accessories or even thesocket can fly off at high speed.
b) Always wear impact-rated safety eyewear when using theimpact wrench.
Select suitable safety eyewear that provides adequate protection for thetask you
are performing.
c) Ensure that theworkpiece is securely fastened or clamped.
4
Entanglement hazards
a) Loose-fitting clothing, jewellery, necklaces or hair which becomes entangled
with thetool could result in strangulation, constriction or crushing.
b) Gloves can become entangled in therotating drive, resulting in severed or
broken fingers.
c) Rubber-coated or steel-reinforced gloves can easily become caught in
rotating sockets or extension bars.
d) Do not wear loose-fitting gloves or gloves with cut or frayed fingers.
e) Never hold onto thedrive anvil, socket or extension bar.
f) Keep hands away from rotating drive anvils.
Connection to the air supply system
a) This tool must only be connected to aclean, filtered and dry air supply
which provides anair pressure at thetool of 6.3 bar (90 psi). Warning: Too
high apressure will reduce thelifespan of thetool and could cause serious
personal injuries.
b) Connect thetool to theair supply using ahose designed for high pressure air.
c) Fit aquick-connect coupling in theair hose and aregular inlet nipple onto
theimpact wrench. Do not attach aquick-connect coupling to theimpact
wrench itself, as this would retain pressure in thetool even when theair hose
has been disconnected.
d) In order for thetool to work at its full capacity, theair compressor must
provide thetool with at least thetool’s rated air consumption.
e) Only use air hoses of therecommended dimension and length. Do not
connect thetool to theair compressor without incorporating aneasy to
reach and operate air cut-off valve.
f) Make sure that any water which has condensed in thetank of theair
compressor or theair hoses is emptied out regularly to prevent water being
delivered into thetool. Water in thesystem could freeze in thehose or cause
thetool to rust.
ENGLISH
Explanation of symbols
Read theinstruction manual before operating thetool.
Always wear ear protection.
Always wear eye protection.
5
Description
ENGLISH
1
2
1. ½″ square drive anvil
2. Hammer mechanism
lubrication point
3. Trigger
4. Exhaust port
5. Air inlet coupling
6. Function selector
3
4
5
6
Lubrication
The air supply to thetool can be lubricated by connecting amist-oiler into theair line
or by applying afew drops of oil to thetool’s air inlet nipple before connecting theair
hose. The tool needs to be lubricated at different intervals depending on how often it
is used.
Lubrication of the air motor
The impact wrench’s air motor should be lubricated
before initial use and before each subsequent use
thereafter. Use aneasy-flowing, resin-free and acid-free
oil with aviscosity grade of max 22, such as sewing
machine oil or oil designed for air tools and machines.
Disconnect theimpact wrench form theair hose, hold
theimpact wrench upside down and drip 2–3 drops
of oil into theair inlet (5). Do not apply too much oil;
any excess oil will be sprayed out of theexhaust port.
You should therefore hold arag over theexhaust port
and make sure that no people or sensitive objects are
close by.
5
6
Lubrication of the hammer mechanism
If you do not use theimpact wrench very often, thehammer mechanism does not
need lubricating more than 1–2 times amonth. If theimpact wrench is used daily,
thehammer mechanism should be lubricated every day.
Disconnect theimpact wrench from theair hose.
Remove thescrew (2) and drip 2–3 drops of oil
into thehole. There is alittle o-ring on thescrew,
make sure that it is not misplaced. Screw in
thescrew again, making sure that theo-ring is in
place. Engine oil can be used here.
2
Operating instructions
ENGLISH
1. Remove theprotective plug from theair inlet (5). Screw theair inlet nipple into
theair inlet (5). Use some form of thread sealant to ensure that theseal is airtight.
2. Fit asocket onto theanvil (1).
Use only undamaged impact
sockets.
3. Connect thequick-connect coupling
of theair hose to theair inlet nipple
on theimpact wrench.
7
4. Select thedirection of rotation and theimpact force using thefunction selector (6):
ENGLISH
Clockwise rotation
Turn thefunction selector clockwise
to tighten nuts/bolts (forward). There
are 3 forward settings for tightening
with different impact forces: low –
medium – high. Always begin with
thelowest force and then increase if
necessary.
5. When starting theimpact wrench hold it in both hands (if possible) and pull
thetrigger.
Anticlockwise rotation
Turn thefunction selector
anticlockwise to untighten nuts/bolts
(reverse). There is only one reverse
setting – full impact force.
Troubleshooting
The impact wrench
fails to deliver full
power or does not
rotate at all.
The tool is unlubricated.Lubricate thetool with appropriate
oil, refer to theLubrication section.
Low air pressure.Adjust thepressure regulator on
thecompressor to 90 psi/6.3 bar.
The function selector is in
thewrong position.
The pressure keeps falling. Air hose is too long or has too small
Worn/broken rotor blades
in air motor.
Water or spray blows out
of theexhaust.
If theimpact wrench
has been left unused
for along time therotor
blades in theair motor
might have stuck.
Check and adjust.
abore causing pressure drop.
Check and replace it with ashorter
hose or one with alarger bore.
Replace.
Empty any condensation from
thetank and hose.
Lubricate thetool with appropriate
oil, refer to theLubrication section.
Then run thetool on High impact
force for about 30 seconds.
Refer to Operating instructions.
If this doesn’t help, repeat
theprocedure.
8
Responsible disposal
This symbol indicates that this product should not be disposed of with
general household waste. This applies throughout the entire EU. In order
to prevent any harm to the environment or health hazards caused by
incorrect waste disposal, the product must be handed in for recycling
so that the material can be disposed of in a responsible manner. When
recycling your product, take it to your local collection facility or contact
the place of purchase. They will ensure that the product is disposed of in
an environmentally sound manner.
Specications
Anvil ½″ square drive
Air consumption 185 l/min
No-load speed 7500 rpm
Max impact force 750 Nm
Air inlet coupling ¼″ NPT
3
Recommended hose bore diameter
Max working pressure 6.3 bar (90 psi)
Weight 2.5 kg
Sound pressure (LpA) 95 dB(A) K: 3 dB(A)
Sound power level (LwA) 106 dB(A) K: 3 dB(A)
Vibration level a
3.12 m/s² K: 1.5 m/s²
h
/8″
ENGLISH
9
Mutterdragare ½″
Art.nr 40-8665 Modell PAT-106
Läs igenom hela bruksanvisningen före användning och spara den sedan för framtida
bruk. Vi reserverar oss för ev. text- och bildfel samt ändringar av tekniska data.
Vid tekniska problem eller andra frågor, kontakta vår kundtjänst.
Säkerhet
Varning! Läs hela bruksanvisningen innan du använder produkten och spara den för
SVENSKA
framtida bruk. Se till att läsa och förstå manualens innehåll innan verktyget används.
Om detta inte följs kan det leda till allvarliga personskador.
Varning! Överskrid inte rekommenderat arbetstryck, 6,3 bar (90 psi). Ett för högt tryck
kan få mutterdragaren att explodera med allvarliga personskador eller dödsfall som följd.
a) Koppla bort mutterdragaren från luftslangen före byte av verktyg och tillbehör
samt vid service eller då den inte används.
b) Använd alltid skyddsglasögon och hörselskydd när mutterdragaren är i bruk.
c) Bär inte löst sittande kläder eller smycken. Håll undan hår, kläder och löst
sittande handskar från rörliga delar. Lösa kläder, smycken eller långt hår kan
fastna i mutterdragarens rörliga del och orsaka personskada.
d) Håll inte in avtryckaren när luftslangen ansluts.
e) Använd endast tillbehör och anslutningar avsedda för luftdrivna verktyg.
VARNING! Använd enbart krafthylsor avsedda för mutterdragare. Använd inte
vanliga hylsor avsedda för handverktyg, slitna eller skadade tillbehör.
f) Håll inte in avtryckaren innan hylsan anslutits till muttern eller skruven.
Hylsan/verktyget ska vara ordentligt fastsatt.
g) Innan verktyget används, kontrollera att alla anslutningar sitter ordentligt fast
och att luftslangarna inte är skadade.
h) VARNING! Koppla bort luftanslutningen innan hylsan/verktyget monteras
eller service utförs.
i) Detta verktyg med tillbehör får inte modifieras på något sätt.
10
Risker på arbetsplatsen
a) Håll arbetsområdet rent och bra belyst.
b) De vanligaste orsakerna till allvarliga skador eller dödsolyckor är när man
halkar, snubblar eller faller. Var uppmärksam på hängande slangar och hala golv.
c) Se till att ha god balans och bra fotfäste.
d) Enformiga arbetsrörelser, obekväma ställningar och vibrationer kan vara
skadliga för händer och armar.
e) Höga ljudnivåer kan medföra bestående hörselskador. Använd alltid hörselskydd.
f) Undvik inandning av damm eller hantering som kan vara farlig för hälsan.
g) Se till att människor och djur håller avstånd till verktyget när det används.
h) Detta verktyg är inte avsett att användas i närheten av explosiva material
och är inte isolerat för kontakt med strömkälla.
Personlig säkerhet
a) Var uppmärksam på vad du gör och använd sunt förnuft när du använder ett
pneumatiskt handverktyg. Använd inte ett handverktyg om du är trött eller
påverkad av droger, alkohol eller medicinering. Ett ögonblicks ouppmärksamhet
när du använder ett handverktyg kan resultera i allvarlig personskada.
b) Använd skyddsutrustning. Bär alltid skyddsglasögon. Användning av skydds-
utrustning som andningsskydd, halksäkra skyddsskor, hjälm och hörselskydd vid
behov minskar risken för personskada.
c) Undvik oavsiktlig start. Håll inte fingret på avtryckaren när du ansluter luftslangen
eller byter hylsa.
d) Sträck dig inte för långt. Se till att du står stadigt med god balans hela tiden.
Detta möjliggör bättre kontroll i oväntade situationer.
e) Bär lämplig klädsel. Bär inte löst sittande kläder eller smycken. Håll undan hår,
kläder och handskar från rörliga delar. Lösa kläder, smycken eller långt hår kan
fastna i rörliga delar.
f) Använd utrustning för utsugning och uppsamling av damm vid damm-
relaterade arbeten.
g) Håll mutterdragaren i de isolerade greppytorna om verktyget kan komma
i kontakt med dolda spänningsförande delar. Metalldelar på mutterdragaren
kan bli spänningsförande och ge användaren elektriska stötar.
h) Undvik direkt kontakt med tillbehör under och efter användning.
SVENSKA
Risker med kringygande föremål
a) Delar av arbetsstycket, på tillbehör eller till och med det monterade verktyget
kan kastas iväg med hög kraft.
b) Använd alltid slagtåligt ögonskydd när du arbetar med mutterdragare.
Välj ett lämpligt ögonskydd som ger tillräckligt skydd för varje arbetsmoment.
c) Se till att arbetsstycket är säkert fastsatt.
11
Risk för att fastna
a) Det kan medföra risk för kvävning, skalpering och/eller sönderslitning om
löst hängande kläder, smycken, halsband, hår eller löst hängande handskar
fastnar i verktyget.
b) Handskar kan fastna i det roterande verktyget och medföra skadade eller
brutna fingrar.
c) Gummerade eller metallförstärkta handskar kan lätt fastna i roterande hylsor
och förlängare.
d) Använd inte löst hängande handskar eller handskar som är slitna.
e) Håll aldrig i drivtapp, hylsa eller förlängare.
SVENSKA
f) Håll händerna borta från roterande drivtapp.
Anslutning till tryckluftssystem
a) Verktyget ska anslutas till ett tryckluftssystem som har arbetstryck 6,3 bar
(90 psi) och som ger ren, filtrerad och torr luft. Varning! För högt tryck minskar
verktygets livstid mycket och kan ge allvarliga personskador.
b) Anslut verktyget med en slang som är avsedd för tryckluft.
c) Montera en snabbkoppling i slangen och en passande nippel på verktyget.
Montera inte en snabbkoppling på verktyget, då är inte verktyget trycklöst
även om luftslangen är bortkopplad.
d) För att verktyget ska leverera full kapacitet måste kompressorn avge minst
luftverktygets angivna luftförbrukning.
e) Använd slangar av rekommenderad dimension och längd. Anslut inte
verktyget till kompressorn utan att infoga en avstängningsventil som är lätt
åtkomlig och enkel att använda.
f) Se till att kondensvatten i kompressortank och slangar töms ur regelbundet
så att inte vatten följer med ut i tryckluftssystemet. Dels kan vattnet frysa i
slangen, dels kan det ge rostskador på verktyget.
Förklaring av symboler
Läs bruksanvisningen före användning.
Använd alltid hörselskydd.
Använd alltid skyddsglasögon.
12
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.