Cobalt Digital Inc 8310(-C), 8321-C, 8310, 8321 User Manual

Cobalt Digital Inc.
8310(-C) (10-Slot)
8321(-C) (20-Slot)
openGearTM 2RU Frame and
Power Supply (PS-8300)
8310/8321-UM Version: 1.0
Page 2 8310/8321 User Manual ••• (V 1.0)
openGearTM 2RU Frame and Power Supply (PS-8300) User Manual
Cobalt Digital Inc. Part Number: 8310/8321-UM
Document Version: 1.0
Printed in the United States.
Last Author: CGG
Printing Date: 8/28/09
The information contained in this Owner’s Manual is subject to change without notice or obligation.
Copyright
© 2009 Cobalt Digital Inc. All rights reserved. Contents of this publication may not be reproduced in any form without the written permission of
Cobalt Digital Inc. Reproduction or reverse engineering of copyrighted software is prohibited.
Notice
The material in this manual is furnished for informational use only. It is subject to change without notice and should not be construed as a commitment by Cobalt Digital Inc. Cobalt Digital Inc. assumes no responsibility or liability for errors or inaccuracies that may appear in this manual.
Trademarks
is a registered trademark of Ross Video Limited.
is a registered trademark of Cobalt Digital Inc.
All other product names and any registered and unregistered trademarks mentioned in this manual are used for identification purposes only and remain the exclusive property of their respective owners.
8310/8321 User Manual ••• (V 1.0) Page 3
Important Regulatory and Safety Notices
Before using this product and any associated equipment, refer to the “Important Safety Instructions” listed below so as to avoid personal injury and to prevent product damage.
Products may require specific equipment, and /or installation procedures be carried out to satisfy certain regulatory compliance requirements. Notices have been included in this publication to call attention to these Specific requirements.
Symbol Meanings
This symbol on the equipment refers you to important operating and maintenance (servicing) instructions within the Product Manual Documentation. Failure to heed this information may present a major risk of damage or injury to persons or equipment.
Warning
The symbol with the word “Warning” within the equipment manual indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury.
Caution
The symbol with the word Caution within the equipment manual indicates a potentially hazardous situation, which if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices.
Notice
The symbol with the word Notice within the equipment manual indicates a situation, which if not avoided, may result in major or minor equipment damage or a situation which could place the equipment in a non-compliant operating state.
Warning
Hazardous
Voltages
This symbol is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product enclosure that may be of sufficient magnitude to constitute a risk of shock to persons.
ESD
Susceptibility
This symbol is used to alert the user that an electrical or electronic device or assembly is susceptible to damage from an ESD event.
Page 4 8310/8321 User Manual ••• (V 1.0)
Important Safety Instructions
Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions.
Warning
The safe operation of this product requires that a protective earth connection be provided. A grounding conductor in the equipment's supply cord provides this protective earth. To reduce the risk of electrical shock to the operator and service personnel, this ground conductor must be connected to an earthed ground.
Use only power cords specified for this product and certified for the country of use. Refer to the Product Power Cord Requirement Section that follows.
Do not defea t the safety purpose of t he grounding-type plug. A grounding type plug has two blades and a third grounding prong. The third prong is provided for your safety. If the provided plug does not fit in to your outlet, consult an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinching particularly at plugs, convenience receptacles, and point where they exit from the apparatus.
Warning
Indoor Use: “WARNING – TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPERATUS TO RAIN OR MOISTURE
Do not use this apparatus near water. Do not block any ventilation openings. Install in accordance with manufacturer’s
instructions. Do not install near heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat. Only use attachments/accessories specified by the manufacturer. Unplug this appa ratus during lightning storms or when unused for long perio ds of
time. Clean only with a dry cloth.
Warning
Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug damage, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Warning
Certain parts of this equipment still present a safety hazard, with the power switch in the OFF position. To avoid electrical shock, disconnect all A/C power cords from the chassis' rear appliance connectors before servicing.
Caution
To reduce the risk of fire, replacement fuses must be the same type and rating.
Caution
Service barriers within this product are intended to protect the operator and service personnel from hazardous voltages. For continued safety, replace all barriers after servicing.
Warning
This product contains safety critical parts, which if incorrectly replaced may present a risk of fire or electrical shock. Components contained within the products power supplies and power supply area, are not intended to be customer serviced and should be returned to the factory for repair.
8310/8321 User Manual ••• (V 1.0) Page 5
Product Power Cord Requirements
Warning
North American Line Voltages 100 - 120 Volts
This product is supplied with certified 10A/125V SVT type supply cords. Conductors are color coded white (neutral), black (line) and green or green/yellow
(ground). Operation of this equipment at line voltages exceeding 130V requires that alternative
supply cords with appropriate voltage and current ratings be used
Warning
International Line Voltages 200 - 240 Volts
This product has been designed for use with certified IEC 320- C13 10A/250V - H03 VV-F3G 1.00mm
2
type line cord.
International product orders are supplied with a certified 10A/250V line cords, utilizing a molded 3-pin IEC 320-C13 type connector at one end and stripped conductors on the other. One line cord is provided. Conductors are CEE color coded; blue (neutral), brown (line), and green/yellow (ground).
Installation by a qualified Electrician, of an appropriately approved A/C wall plug certified for the country of use, is required.
Alternatively, other IEC 320 C-13 type power cords may be used, provided that they meet the necessary safety certification requirements for the country in which they are to be used. Refer to the correctly specified line cord above.
EMC Notices
US FCC Part 15
This equipment has been tested and found to comply with the limits for a class A Digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense.
Notice
Changes or modifications to this equipment not expressly approved by Cobalt Digital Inc. could void the users authority to operate this equipment.
CANADA
This Class “A” digital apparatus complies with Canadian ICES-003.
EUROPE
This equipment is in compliance with the essential requirements and other relevant provisions of CE Directive 93/68/EEC.
INTERNATIONAL
This equipment has been tested to CISPR 22:1997 along with amendments A1:2000 and A2:2002 and found to comply with the limits for a Class A Digital device.
Notice
This is a Class A product. In domestic environments this product may cause radio interference in which case the user may have to take adequate measures.
Page 6 8310/8321 User Manual ••• (V 1.0)
Maintenance/User Serviceable Parts
Routine maintenance to this Cobalt Digital Inc. product is not required. This product contains no user serviceable parts. If the frame does not appear to be working properly, please contact Technical Support using the numbers listed under the Contact Us section on the last page of this manual. All Cobalt Digital Inc. products are covered by a generous 5-year warranty and will be repaired without charge for materials or labor within this period. See the Warranty and Repair Policy section in this manual for details.
Environmental Information
The equipment that you purchased required the extraction and use of natural resources for its production. It may contain hazardous substances that co uld impact health and the environment.
To avoid the potential release of those substances into the environment and to diminish the need for the extraction of natural resources, Cobalt Digital Inc. encourages you to use the appropriate take-back systems. These systems will reuse or recycle most of the materials from your end-of-life equipment in an environmentally friendly and health conscious manner.
The crossed-out wheeled bin symbol invites you to use these systems.
If you need more information on the collection, reuse, and recycling systems, please contact your local or regional waste administration.
You can also contact Cobalt Digital Inc. for more information on the environmental performances of our products.
8310/8321 User Manual ••• (V 1.0) Page 7
Contents
Introduction 9
In This Chapter..........................................................................................................................9
A Word of Thanks .......................................................................................................9
Overview.....................................................................................................................9
Features .....................................................................................................................10
Documentation Terms...............................................................................................11
Installation and Setup 12
In This Chapter........................................................................................................................12
Static Discharge.........................................................................................................12
Unpacking.................................................................................................................. 13
Installing the Frame...................................................................................................14
Power Supply PS-8300 and Power Cable..................................................................14
Fault Reporting..........................................................................................................15
Improving Performance.............................................................................................15
Ventilation and Cooling.............................................................................................15
Cable Connections.....................................................................................................16
Rear I/O Modules......................................................................................................17
SMPTE 269M Fault Reporting Option 20
In This Chapter........................................................................................................................20
Overview...................................................................................................................20
Frame Connections ....................................................................................................21
Details........................................................................................................................21
Specifications 22
In This Chapter........................................................................................................................22
Technical Specifications............................................................................................22
Frame Features 25
In This Chapter........................................................................................................................25
Cooling Features......................................................................................................................26
Installing the Cooling Fan Module............................................................................26
Cooling Fan Functions and User Controls.................................................................27
Installing the Controller Card..................................................................................................28
Functions of the Controller Card...............................................................................28
Controls and LEDs for the Controller Card...............................................................29
Remote Control Networking Features......................................................................................31
Installing the Network Controller Card .....................................................................31
Ethernet Setup ...........................................................................................................31
Functions of the Network Controller Card ................................................................32
Controls and LEDs for the Network Controller Card................................................32
DashBoard and DashBoard Lite Control System Software.......................................35
SNMP Monitoring and Control.................................................................................35
Rear Support Bars and Brackets..............................................................................................37
Page 8 8310/8321 User Manual ••• (V 1.0)
Installing the Rear Support Bars and Brackets..........................................................37
Service Information 43
In This Chapter ........................................................................................................................43
Troubleshooting Checklist.........................................................................................43
Frame Controller Alarm Mute/Bootload Button........................................................43
Warranty and Repair Policy.......................................................................................45
Ordering Information 46
In This Chapter ........................................................................................................................46
Contact Us 48
Contact Cobalt Digital Inc.......................................................................................................48
Visit us at the Cobalt Digital Inc. website. ...............................................................................48
8310/8321 User Manual ••• (V 1.0) Page 9
Introduction
In This Chapter
This chapter contains the following sections:
A Word of Thanks
Overview
Features
Documentation Terms
A Word of Thanks
Congratulations on choosing the openGearTM 2RU Frame and Power Supply (PS-8300). The Cobalt Digital Inc. openGear
TM
line includes video decoders and encoders, audio embedders and de-
embedders, distribution amplifiers, format converters, and much more. Cobalt Digital Inc. openGear
TM
modular conversion gear will meet your signal conversion needs now, and well into the future. Should you have questi ons or concerns pertaining to the installati on or operatio n of your frame, please
contact Cobalt Digital Inc. (Contact information is supplied on the back cover of this manual.) Our technical staff is always available for consultation, training, or service.
Overview
Note: Refer to 8321 20-Slot Frame Setup (page 38) in this manual if you are installing an 8321
frame. This chapter contains installation information unique to the 8321 frame. In all other aspects for either frame, follow the installation instructions as described in the following sections.
The 8310 is a 2RU modular frame, designed to accommodate up to 10 cards of the openGear
TM
product family. The 8321 is a 2RU modular frame, designed to accommodate up to 20 cards of the openGear
TM
product family.
Modular Frame Architecture
The 8310 blends the simplicity of a fixed rear connector frame, and the flexibility of independent rear BNC connector modules.
For most applications which use BNC connectors, the 8310 is available with a fixed 100-BNC rear module. This frame configuration allows any openGear
TM
card using only BNC connectors to be installed into any slot, without restrictions. Installation of separate rear modules is not required. Unused slots can be pre-wired into a facility, and installation of cards can be done at any time without accessing the rear of the frame.
Page 10 8310/8321 User Manual ••• (V 1.0)
For applications where other types of I/O connections are necessary (such as twisted-pair audio or fiber interfaces), the frame also supports slot-dependent rear modules. Rear modules can be ordered with cards, and are easy and quick to install.
Robust Power Supplies
The 8310 frame can accommodate two front-loaded PS-8300 power supplies. Although a single power supply can fully power a loaded frame, the addition of a second (optional) power supply gives the frame full power redundancy. Each power supply is fed by a separate power cord, which is held in position to guard against accidental power loss.
Each power supply contains an independent cooling fan, status LED, and a front-mounted power switch.
Each frame comes standard with one PS-8300 power supply.
Optional Cooling Fans
The frame has been designed with an advanced cooling architecture to increase ventilation. For applications where the total card load is less than 40 Watt, the 8310 can be used without cooling
fans. Frames should be mounted with 1RU empty space between frames. For applications where frames are mounted directly above or below other equipment, or where the total
card power load is greater than 40 Watt, an optional cooling fan kit must be added. These front-door mounted fans provide forced air cooling for all cards, and additional cooling for the power supplies. An intelligent fan controller adjusts fan speed with changes in frame power loading. Particular attention has been paid to frame acoustics in order to keep fan noise to a minimum.
Additional Frame Accessories
To help reduce mechanical stress due to cable weight, a rear frame support bracket (FSB-8310) is also available.
openGear
TM
Cards
The 8310 will accommodate any openGear
TM
8200 series cards.
Important
For long-term reliability and increased product lifespan, total dissipation of all cards installed in a 2RU frame must not exceed 40 Watt total without the use of the Cooling Fan Module. Refer to the section, Ventilation and Cooling,” in this manual, for details.
Features
The following features make the 8310 frame the best solution for standard and high definition terminal equipment:
2RU Frame houses up to 10 cards
Can house any mix of analog, digital, video and audio cards in the same frame
Available with fixed 100-BNC rear module, or individual card specific modules for
connector flexibility
Heavy-duty hinged front panel lowers to allow easy card insertion
Durable powder-coat paint finish
8310/8321 User Manual ••• (V 1.0) Page 11
Aluminum construction red uces overall weight
Two independent looping Reference Inputs feed all card slots
SMPTE alarm interface for simple monitoring
Ethernet po rt for optional networked control
Robust 150 Watt Power Supply with integral cooling fan
Optional redundant power supply is hot-swappable for 24/7 operation
Power switch is accessible from front of the rack frame
Power supplies are replaceable from the front of the frame without requiring rear-
frame access
Separate power cords to each supply for power feed redundancy
PowerLock cord retainer mechanism guards against accidental power loss
Optional Cooling Fan Module for increased ventilation and enhanced reliability
Fan Fail and Error Indicator LEDs on front of the frame (available with optional
Cooling Fan Module )
Optional Ethernet based Frame Controller for remote setup, monitoring, and control
5-year transferable warranty
Documentation Terms
The following ter ms ar e used throughout this guid e:
Frame refers to the frames that house the 8200 series cards.
All references to the 8310 and 8321 also include the 8310-C and 8321-C versions
(respectively) with the cooling fan option. Refer to the section Cooling Features for details.
Operator and User both refer to the person who uses the frame.
System and Video system refers to the mix of interconnected digital and analog
production and terminal equipment in which the frame operates.
Page 12 8310/8321 User Manual ••• (V 1.0)
Installation and Setup
In This Chapter
This chapter contains the following sections:
Static Discharge
Unpacking
Installing the Frame
Power Supply PS-8300 and Power Cable
Fault Reporting
Improving Performance
Ventilation and Cooling
Cable Connections
Rear I/O Modules
Static Discharge
Whenever handling the frame and other related equipment, please observe all static discharge precautions as described in the following note:
8310/8321 User Manual ••• (V 1.0) Page 13
ESD
Susceptibility
Static discharge can cause serious damage to sensitive semiconductor d evices. Avoid handling ci rcuit boards in high static environments such as carpeted areas, and when wearing synthetic fiber clothing. Always exercise prope r grounding precautions when working on circuit boards and related equipment.
Unpacking
Unpack each frame you received from the shipping container, and check the contents against the packing list to ensure that all items are included. If any items are missing or damaged, contact your sales representative directly.
Page 14 8310/8321 User Manual ••• (V 1.0)
Installing the Frame
The frame frame mounts in the rack frame by means of four ra ck screws fastened through the front mounting flanges. This should normally be sufficient to carry the load, including the weight of accompanying cables. However, in certain applications such as mobile truck installations, it may be desirable to also support the rear of the frame. The optional FSB-8310 Rear Support Bars and Brackets are specifically engineered to compensate for extra load stress. Refer to the section Installing the Rear Support Bars and Brac kets of this manual for installation instructions. The Ordering Information section at the end of this manual provides contact information for acquiring this equipment.
Note the following installation requirements:
Rack Units: 2 RU
Height: 3.5 inches (8.89 cm)
Depth: 15.625 inches (40 cm)
Rack: standard 19 inch wide equipment rack
Install the frame for maximum stability during operation and in such a way as to allow adequate ventilation. Ensure that adequate space exists behind the frame and on the right side of the frame for airflow exhaust. The location of the frame should be accessible, dry, and dust free.
Power Supply PS-8300 and Power Cabl e
The frame comes standard with one PS-8300 power supply, with a second optional power supply available for redundancy. For redundancy, and in applications where the equipment is used in a critical signal path, we recommend that two power supplies be used in the frame. One A/C power cable has been provided with each power supply ordered.
For further redundancy, each power cord should be connected to a separate power source for protection against failure of the A/C power circuit. Reliability will also be improved when using redundant supplies as each supply shares the load. In the event of one power supply failure, card power is seamlessly transferred t o the other redunda nt power supply. Although the power supply is "hot­swappable," turning the power supply off before inserting or removing it from the frame will increase the lifespan of the connectors.
Installing the Frame Power Supply
The power supply plugs into the right-hand section of the chassis. The universal power supply supports all worldwide AC power voltages, and no power adjustments are required. The secondary (redundant) power supply, if ordered, is already installed in the frame.
Use the following procedure to install the power supply:
Warning
Warning
Hazardous
Voltages
1. Carefully unpack the power supply from its box, and retain all packing material for future use, if required.
2. Align the power supply into an unused power slot on the right side of the frame.
3. Push the power supply in firmly to ensure a tight connection at the rear of the frame.
8310/8321 User Manual ••• (V 1.0) Page 15
Note
In case of a power supply failure, contact your openGear
TM
dealer.
The PS-8300 is a power factor corrected supply, capable of working with all world AC standards (100-240V). The supply has an indicator LED on the front, and an error detection circuit that will indicate the conditions described in Table 1.
Table 1. Status LED Descri pt i ons
LED Color Display and Description
Fault Red When lit, an alarm condition is occurring on a card. (CFM-8310 option) Fan Fail Red When lit, a fan on the frame door or PS-8300 is stalled. (CFM-8310 option)
Power Supply
Green/ Red
When lit green, the PS-8300 is operating normally. When flashing red:
there is an output over or under voltage condition on the PS-8300
there is no A/C; assumed that the second supply is operating
normally
Fault Reporting
If the optional CFM-8310 module is installed, the error conditions listed in Table 1 above will trigger the SMPTE 269M fault reporting circuit, and the signal will be sent to the Fault BNC on the back of the frame. Refer to the section Fault Report Connector in this chapter and the chapter, SMPTE 269M Fault Reporting Option” for further details.
Improving Performance
To improve performance and reliability, the PS-8300 has an on-board fan. Under high load conditions (>40 Watt), the optional CFM-8310 Cooling Fan Module must be added for increased ventilation.
Ventilation and Cooling
This frame has been specially engineered to minimize internal heat buildup and thus improve card reliability. However, for long-term reliability and increased product life of the frame (without the Cooling Fan Module installed), it is recommended that the total power dissipation of all cards installed in the frame should not exceed 40 Watt, and to leave an empty 1RU panel space above and below the frame for improved heat dissipation. For information on the power dissipation of openGear
TM
cards,
please refer to the openGear
TM
Product Catalog or visit our website.
For applications using less than 40 Watt in a non-ventilated frame, but where the individual card power consumption is greater than 8 Watt, the cards should be evenly distributed in the frame. This will prevent the creation of concentrated heat, or unbalanced heat-rise areas, in the frame.
For applications that require greater heat dissipation, or where the card power consumption is greater than 40 Watt, it is necessary to use the 8310-C frame (with Cooling Fan Module installed), or to install the CFM-8310 Cooling Fan Module field upgrade option. When the Cooling Fan Module is installed, the frame and PS-8300 can supply up to 120 Watt of card power. Under these ventilated conditions, there is no requirement for extra spacing between the frames. The 8310-C (or 8310 with CFM-8310 option) can be stacked one on top of the other, a feature that is highly desirable in densely crowded rack frame environments.
Page 16 8310/8321 User Manual ••• (V 1.0)
Notice
For reliable performance, it is recommended that the frame door not be opened for longer than 5 minutes when using the Cooling Fan Module option on frames loaded with more than 40 Watt.
Figure 1. Cooling Fan Module Frame Stacking Options
Cable Connections
SMPTE Alarm BNC
Power Supply Inputs
Ethernet Connector
RossBUS Connector
Reference Connectors
Figure 2. Frame Cable Connectors
Power Cable Connection
Use the following procedure to connect the power cable:
1. Connect the supplied power cable’s three prong male connector to an AC outlet.
2. Connect the cables female IEC connector to the frame socket marked PSU 1.
3. If the Redundant Power Supply option is installed, repeat ste p 1 and 2, plugging the
second IEC connector into PSU 2.
E
mpty Space
E
mpty Space
8310-C
Max. 120W Module Power
8310-C
Max. 120W Module Power
8310-C
Max. 120W Module Power
8310
Max. 40 Watt
Without Fan Kit: Fan Kit Installed:
8310/8321 User Manual ••• (V 1.0) Page 17
4. Each AC connector includes a Powerlock, which is designed to retain the power cable
connector. Clip the Powerlock over the shoulder of the inserted AC cable end.
5.
Warning
Warning
Hazardous
Voltages
Note In some countries, it may be necessary to supply the
correct mains supply cord. Use only an approved IEC 320 C-13 type A/C line cord rated for a minimum 10A at 250V and certified for the country of use.
Further, the safe operation of this product requires that a protective earth connection be provided. This protective earth is provided by the grounding conduc tor in the equipment’s supply cord. To reduce the risk of electrical shock to operator and service pe rsonnel, this ground conductor must be connected to an earthed ground.
Rear I/O Modules
Depending on the frame model you purchased, there may be variations in the BNC rear I/O modules connected to it. If the frame was ordered with cards requiring custom rear I/O modules, the appropriate modules will be installed at the factory or included with the card modules.
8310 and 8310-C frames come without a 100-BNC rear I/O module. Cards ordered with these
frames require rear I/O modules tailored to the card.
8310-BNC and 8310-C-BNC frames come with fixed 100-BNC rear I/O module.
Consult the installation section of each cards manual for BNC designations. Each card comes with a BNC label to place on the frames BNC rear I/O module. Each card also has BNC designations printed on the card PCB.
Figure 3. 100 BNC Rear I/O Module
Figure 4. AES-BNC Rear I/O Module
Figure 5. 10 BNC Rear I/O Module
Figure 6. Blank Rear I/O Module
Page 18 8310/8321 User Manual ••• (V 1.0)
Rear I/O Module Installation
If you are installing an openGearTM card in a 8310-C-BNC or 8310-BNC frame, skip this section. If you received a custom rear I/O module for your openGear
TM
card, you will need to install the I/O
module in your 8310 frame before you can connect cables. Use the following procedure to install the DFR-RM-82xx in the 8310 digital distribution frame:
1. Ensure that the frame is properly installed according to instructions in the section
Installing the Frame of this manual.
2. On the rear of the 8310, locate the card frame slot.
3. As shown in Figure 7, seat the bottom of the DFR-RM-82xx in the seating slot at the
base of the frame’s back plane.
Figure 7. Rear Module Installation
4. Align the top screw of the DFR-RM-82xx with the screw hole on the top edge of the
DRF-8310 back plane.
5. Using a Phillips driver and the supplied screw, fasten the DFR-RM-82xx panel to the
8310 back plane. Do not over tighten.
6. Ensure proper frame cooling and ventilation by having all rear frame slots covered
with rear I/O modules or blank metal plates. If you need blanks, see the chapter, Ordering Information and contact your openGear
TM
sales representative.
This completes the procedure for installing the DFR-RM-82xx in the 8310 digital distribution frame.
SMPTE Alarm Connector
The SMPTE Alarm BNC connector may be wired to an external alarm system for reporting alarms in SMPTE 269M format. The circuit can drive a 20mA alarm load. For more details on this type of system, refer to the document ANSI/SMPTE 269M - 1999, available from SMPTE. Refer also to page 19-20, SMPTE Fault Reporting Option, for further details.
8310/8321 User Manual ••• (V 1.0) Page 19
openBUS Connector
This RJ45 connector is used to exchange information data from cards installed in the 8310 frame to an external monitoring/control system. Only cards having the openBUS interface will be able to be monitored and controlled this way. This is reserved for future use with openGear
TM
products.
Notice
Connect only openBUS compatible devices and cables on this connector otherwise damage can occur to the frame or to the incompatible device.
Ethernet Connector
This RJ45 connector is used to connect the optional MFC-8310-N frame controller card to an external Ethernet network. This standard 10/100Base-TX RJ45 Ethernet connector is used to exchange information with an external monitoring/control system over an Ethernet network. The optional MFC-8310-N is required to bridge the external Ethernet network to the local openBUS for monitoring and control of cards installed in the 8310 frame. Only cards having the openBUS interface will be able to be monitored and controlled this way.
Note
Use up to 100 meters of CAT5 Fast Ethernet cable or better to connect the frame to an external Ethernet hub or switch.
The Ethernet port does not have AutoMDIX support and its RJ45 connector is wired as a Network Interface Card (NIC).
The Ethernet port does not provide Power-over-Ethernet (PoE).
Dual Reference Connectors
Two sets of looping BNC inputs are provided to accept two independent reference signals:
Analog black
Tri-level sync
AES/DARS reference
This feature distributes one or two reference signals to all cards in the frame. Cards which need an external reference use this master reference signal in place of taking the signal from one of the card BNCs. This provides for ease of installation and reduction in reference cabling requirements. If this signal is required, it will be mentioned in the Installation section of the particular card's Owner’s Manual.
If only one reference type is required for the frame, connect it to the REF-1 BNC. If the reference is not being looped to another frame or device, ensure that the Loop Ref BNC is terminated.
Page 20 8310/8321 User Manual ••• (V 1.0)
SMPTE 269M Fault Reporting Option
In This Chapter
This chapter contains the following sections:
Overview
Frame Connections
Details
Overview
The SMPTE 269M Fault Reporting system, also known as a SMPTE “alarm, provides an indication if one or more frame cards encounter a fault or an abnormal condition. This option is available when a Network Controller Card is installed in the Frame Controller Slot. The MFC-8310 is included if the frame has cooling fans in the front door. The individual card(s) can report fault conditions to the Network Controller Card, which in turn outputs to a BNC connector on the openGear
TM
8310 series
frame. When the frame connection is interfaced with a customer-designed system of LEDs or audible alarms, faults can be traced to a specific frame when a card fault occurs within that frame.
8310/8321 User Manual ••• (V 1.0) Page 21
Frame Connections
The SMPTE 269M Fault Reporting connection on openGearTM 8310 series frames is provided by the FAULT BNC connector, for interfacing with a customer-designed alarm system.
SMPTE Fault BNC
Figure 8. SMPTE 269M Alarm Reporting Frame Connect i ons
Details
The fault report contacts are closed when the card detects an internal failure or a power loss condition. The fault report contacts are closed for about 2 milliseconds every 16 ms to report any error for which SMPTE fault reporting has been enabled.
Some internal failures may include:
Hardware failure of any card or power supply.
Loss of AC power to any power supply
Soft errors from any card setup to detect and report such errors
For additional information on alarm system design, refer to the SMPTE document ANSI/SMPTE 269M - 1999.
Page 22 8310/8321 User Manual ••• (V 1.0)
Specifications
In This Chapter
This chapter contains the Technical Specifications table.
Technical Specifications
Table 2. Technical Specifications
Category Parameter Specification
Input 100 - 240VAC, 47-63 Hz, 190 Watt Output 1 +12V, ± 10%, 0.5A - 12.5A Output 2 -7.5V, ± 10%, 0A - 2.5A
PS-8300 Power Supply
Total
Sum of both outputs not to exceed 150 Watt maximum
For safety reasons, Cobalt Digital Inc. power supplies do not fit into rack frames of other manufacturers.
Height 3.5" (90mm) Width 19" (483mm) Depth 15.625" (390mm)
Rack Frame Mechanical
Weight, with 1 PS-8300 installed 10 lbs. (4.5kg) Number of Slots 10
Max Power: +12V Rail 1.0A (12 Watt) Max Power: -7.5V Rail 0.2A (1.5 Watt)
Frame Card Slots
Total 120 Watt, total power consumption not to
exceed 12W maximum per card slot. Max Power: +12V Rail 1.5A (18 Watt) Max Power: -7.5V Rail 0.2A (1.5 Watt)
Frame Controller and Fans
Total 19.5 Watt maximum
OpenBUS Remote Power
Max Power: +12V
2.0A (24 Watt), total frame power not to exceed
150W total.
Reference Inputs
Number of Inputs 2 looping
8310/8321 User Manual ••• (V 1.0) Page 23
Category Parameter Specification
Level 1Vpp nominal
Signal
Analog video sync (black burst or tri-level), or AES/EBU DARS
Impedance
75 terminating Return Loss >30dB to 30MHz Max DC on Ref Input ±1V Alarm Indicator ANSI/SMPTE 269M-1999 contact closure Connector Female BNC Max Voltage 24V DC Max Current 20mA
Loss of AC input power Alarm Conditions
DC output volta ge error
DC output volta ge
DC output current
Critical temperature
PS Monitored Parameters (-C version only)
PS-8300 fan failure
Backplane rail voltage
Cooling fan failure
Frame Monitored Parameters (-C version only)
Ambient temperature
System fault LED
Fan failure LED
Frame controller audio alarm
SMPTE Fault Reporting
Alarm Indicators (-C version only)
Frame door audio alarm Ambient temperature range 0 ºC to 40 ºC
Environmental
Humidity, non condensing <95%
Specifications are subject to change without notice.
Page 24 8310/8321 User Manual ••• (V 1.0)
Important Notes:
The power dissipation of each product installed in this frame is indicated in the Specifications section of the documentation provided with each module. For long-term reliability and increased product life, it is recommended that the total dissipation of all modules installed in a 8310 frame should not exceed 40 Watt total without the CFM-8310, and 120 Watt total with the CFM-8310. In addition, frames without the CFM-8310 should be provided with one rack unit of empty space above and below each frame for ventilation.
Please see the Ventilation and Cooling section in this product's Owners Manual for further information and options for higher load applications requiring greater heat dissip ation.
8310/8321 User Manual ••• (V 1.0) Page 25
Frame Features
In This Chapter
This chapter contains the following sections:
Cooling Features
o Installing the Cooling Fan Module o Cooling Fan Functions and User Controls o Installing the Controller Card o Functions of the Controller Card o Controls and LEDs of the Controller Card
Remote Control Net wor king Features
o Installing the Network Controller Card o Ethernet Setup o Functions of the Network Controller Card o Controls and LEDs of the Network Controller Card
DashBoard and DashBoard Lite Control System Software
SNMP Monitoring and Control
Rear Support Bars and Brackets
o Installing the Rear Support Bars and Brackets
Page 26 8310/8321 User Manual ••• (V 1.0)
Cooling Features
The standard 8310 frame can be also be ordered as the 8310-C version, with the Cooling Fan Module installed as original equipment from the factory. However, for customers wishing to increase the ventilation on their standard 8310 frames, the optional CFM-8310 Cooling Fan Module is available as a field upgrade kit.
The CFM-8310 module consists of a fan board, which installs in the frame door, and a controller card, which installs in a designated frame slot. The controller may be either an MFC-8310, which provides fan control and local alarm monitoring, or an MFC-8310-N , which provides fan control, alarm monitoring, and support for remote monitoring and control via Ethernet. Installation instructions are provided in this chapter for both types of controller cards.
Installing the Cooling Fan Module
This section includes instructions on installing the Fan Board component of the CFM-8310 module and an outline of the Functions and User Controls of the module. After you install the CFM-8310 module, you must install the MFC-8310 or the MFC-8310-N controller card.
Fan Board Installation Instructions
Use the following figure and procedure to install the Fan Board component of the CFM-8310:
Frame Controller MFC-8310 & Connector
Socket
Power
Supply LED Pi pes
Fan PCB 8310A-016
Fan Filter S958-006 (beneath PCB)
8 Nuts 8 Washers
Figure 9. CFM-8310 Cooling Fan Module
8310/8321 User Manual ••• (V 1.0) Page 27
1. Open the CFM-8310 package and remove the components. Verify that all necessary
components are included.
Fan PCB 8310A-016
Fan Filter S985-006
8 nuts 650-007
8 washers 960-025
MFC-8310(-N) Frame Controller Card
2. Turn frame power off.
3. Open the frame door.
4. Carefully remove the door from the frame by unscrewing the two screws that attach
the door to the extender arms.
5. Place the frame door inside up on a clean antistatic workspace.
6. Insert the Fan Filter with the panhandle over the smaller fan vents and the cut corner
adjacent to the LED pipes already on the door. Gently push the filter down so the mounting bolts pass thr ough cleanly.
7. Place a washer on each of the 8 mounting bolts.
8. Align the Fan PCB with the fans up so the LED pipes pass thr ough their board hol es.
9. Ensure the Alarm Mute button clears its door hole and that the Fault and Fan Fail
LEDs clear their door holes while you slowly press the Fan PCB down onto the 8 mounting bolts. See Figure 11 for details on these item locations.
10. On the frame door, check that the Alarm Mute button pushes in and out without
binding.
11. Tighten the 8 nuts until they just make contact with the rubber grommets on the
8310A-016 Fan PCB. Do not over tighten.
12. Reconnect the door to the frame extender arms with the two screws from step 4.
This completes the procedure to install the Fan Board component of the CFM-8310 module. Next you will learn about the CFM-8310 functions and user controls.
Cooling Fan Functions and User Controls
The CFM-8310 provides LED and Alarm switching controls to the front edge of the 8310 frame door. Refer to Table 4 for details on LED functions for the MFC-8310 controller card.
Figure 10. Frame Door Features
Page 28 8310/8321 User Manual ••• (V 1.0)
Next you will install either an MFC-8310 or an MFC-8310-N controller card. Refer to the appropriate section for installation instructions for your specific controller card.
Installing the Controller Card
Use the following procedure to install the MFC-8310 controller card component of the CFM-8310:
Figure 11. MFC-8310 Fan Controller Card and Unscrewed Ret ai ni ng Screw
1. With the frame door open, unscrew the MFC-8310 Card Retaining Screw (Part No.
850-040) enough to eliminate any protrusion into the card guide slot on the right of the screw. If necessary, remove any cards from the frame that would interfere with easy access and lines of sight.
2. Insert the MFC-8310 frame controller card, with the component side out as shown in
Figure 11, into the card guides along the dividing wall between slot 10 and the PS­8300 section of the frame, ensuring the card does not touch the Card Retaining Screw.
3. Slide the card in the slot until firmly seated and so the Card Retaining Screw hole on
the bottom front edge aligns with the mounted nut beside the bottom guide slot.
4. Tighten the Card Retaining Screw through the mounted nut a nd the MFC-8310 Card
Retaining Screw hole, to ensure the card does not move from the slot.
5. Close the door, power up the frame, and check the operation of the fans. If the fans
do not operate, verify that the MFC-8310 is seated properly in the frame backplane and is aligned to the Fan PCB when the door is closed.
This completes the installation of the MFC-8310 controller card for the CFM-8310 Cooling Fan Module. Next you will learn the general functions and controls available on the MFC-8310 controller card.
Functions of the Controller Card
The MFC-8310 controller card component of the CFM-8310 performs several functions:
Monitors frame power usage and sets the fan speed accordingly (higher power consumption
requires higher fan speed for ad equate cooling). The fans always run at maximum speed for 5
8310/8321 User Manual ••• (V 1.0) Page 29
seconds after the fan door is closed, then adjust to the appropriate level based on power consumption.
Monitors the frame door and PS-8300(s) to ensure that fans in all units are operating
correctly.
Monitors the fan door and notifies the user if it is left open too long.
Monitors the status of other cards in the frame via the internal bus.
Generates alarms if any of the monitored functions develop errors.
Next you will learn the various controls and LEDs available on the MFC-8310 controller card.
Controls and LEDs for the Controller Car d
This section provides information on the jumpers, buttons and LEDs for the MFC-8310 controller card. The location of the LEDs and controls for fan, alarm, and communication activity are shown in the
following figure.
Alarm LED
Status OK LED
Comm Activity LED
Alarm Mute/Bootload Button
Alarm Config Jumper
Fan Board Connector Edge
Figure 12. MFC-8310 Card Edge Controls
MFC-8310 Alarm Configuration Jumper
The Alarm Configuration Jumper enables or disables the audio alarm signal. The Alarm LED will still be lit if alarm conditions are occurring, but the audio will be off.
Alarm Mute Button
If the optional CFM-8310 Cooling Fan Module is installed, there is an Alarm Mute Button on the right side of the frame door front. If a card, that is in the frame, is reporting an error, pressing the Alarm Mute Button will mute the audio alarm until another fault condition occurs.
MFC-8310 LEDs
The front edge of the MFC-8310, and the CFM-8310 in the frame door, have LED indicators for cooling module fan, alarm, and communication activity. The CFM-8310 provides LED and Alarm switching controls to the front edge of the 8310 frame door.
Page 30 8310/8321 User Manual ••• (V 1.0)
LED displays and descriptions are provided in the following table:
Table 3. MFC-8310 Controller Card LED Descriptions
LED Color Display and Description
Alarm (MFC-8310)
Red
When lit, an alarm condition is occurring in the frame.
Status OK (MFC-8310)
Green When lit, the MFC-8310 module is operating correctly.
Comm. Activity (MFC-8310)
Yellow When lit, the card is communicating within the frame.
Fault (CFM-8310)
Red When lit, a SMPTE alarm condition is occurring in the frame.
Fan Fail (CFM-8310)
Red When lit, a fan on the frame door or PS-8300 is stalled.
Power Supply (8310)
Green/ Red
When lit Green, the PS-8300 is operating normally When flashing Red:
there is an output over or under voltage condition on the PS-8300
there is no A/C; provided that the second supply is operating normally
8310/8321 User Manual ••• (V 1.0) Page 31
Remote Control Networking Features
This section includes instructions for installing the MFC-8310-N controller card for the CFM-8310 module.
Note: Refer to Cobalt
®
reference guide COMPASS Remote Control User Guide
(PN 9000RCS-RM) for thorough information and step-by-step instructions for setting up network remote control of COMPASS cards using DashBoard and the Network Controller Card. This guide provides information for setting up remote control using either the MFC-8310-N or MFC-8320­N Network Controller Cards.
Installing the Network Controller Card
Perform the physical installation of the MFC-8310-N controller card for the CFM-8310 using the steps provided in the section Installing the Controller Card of this manual. Once the controller card is installed, you can proceed to the section below to set up the Ethernet connection for your card.
Ethernet Setup
Use the following procedure to set up the Ethernet connection for the MFC-8310-N controller card:
1. On the MFC-8310-N card, set DIP_8 to ON. Refer to Figures 13 and 14 for DIP
Switch locations.
2. Power up the MFC-8310-N card. The IP address of the MFC-8310-N card is set to
192.168.1.1 by default.
3. Set the IP Address of your PC to 192.168.1.x, where x is a value other than 1.
Consult your IT Department for details.
4. Point your Web browser to 192.168.1.1, the IP Address of the MFC-8310-N card.
5. Set the following parameters as required:
Frame Name – This name identifies the frame.
DHCP – Set this parameter to Yes if the frame IP Address is to be set
automatically.
IP Address This is the IP Address, which is supplied by your IT Department,
of the card.
NetMask This is the subnet mask for your LAN as supplied by your IT
Department.
Gateway – This is the IP Address for connection outside the subnet.
Time Server – This is the IP Address of the NTP server used as a time source.
Save Changes – Select this button to send your changes to the MFC-8310-N
card. The IP Address of the card is updated.
6. Power down the MFC-8310-N card.
7. On the MFC-8310-N card, set the DIP_8 to OFF.
8. Power up the MFC-8310-N. The card will use the configured IP Address.
9. Verify the configured IP Address of the MFC-8310-N card by pointing your Web
browser to the new address.
Page 32 8310/8321 User Manual ••• (V 1.0)
This completes the procedure to configure the network settings for the MFC-8310-N controller card.
Functions of the Network Controller Card
The MFC-8310-N controller card component of the CFM-8310 performs several functions:
Monitors frame power usage and sets the fan speed accordingly (higher power consumption
requires higher fan speed for ad equate cooling). The fans always run at maximum speed for 5 seconds after the fan door is closed, then adjust to the appropriate level based on power consumption.
Monitors the frame door and PS-8300(s) to ensure that fans in all units are operating
correctly.
Monitors the fan door and notifies the user if it is left open too long.
Monitors the status of other cards in the frame via the internal bus.
Generates alarms if any of the monitored functions develop errors.
Provides an Ethernet connection to allow remote monitoring and control of the frame.
Controls and LEDs for the Networ k Controller Card
This section provides information on the controls and LEDs for the MFC-8310-N controller card. These are similar to the controls and LEDs on the MFC-8310, with some additional LEDs and DIP switches. The location of the controls are show in the following figures.
Figure 13. MFC-8310-N DIP Switc hes
The LED indicators and controls for fan, alarm, and communication activity are shown in the following figure.
8310/8321 User Manual ••• (V 1.0) Page 33
DS1 DS2
DS3
Alarm Mute Button
Fan Board Connector Edge
DS6
DS7
DS5
DS4
Figure 14. MFC-8310-N Card Edge Controls
DIP Switches on the MFC-8310-N
The following DIP Switches are located on the MFC-8310-N controller card.
DIP_1 Switch
DIP_1 switch disables the audio alarm signal as follows:
ON This setting disables the audio alarm.
OFF This setting enables the audio alarm.
DIP_2 to DIP_7 Switches
DIP_2 to DIP_7 switches are not used.
DIP_8 Switch
DIP_8 switch sets the default IP Address of the MFC-8310-N controller card as follows:
ON This setting enables the card to use the default IP Address of 192.168.1.1.
OFF This setting enables the card to use the IP Address configured by the user.
Buttons on the MFC-8310-N
The following buttons are located on the MFC-8310-N controller card.
Alarm Mute/Bootload Button
When a card in the frame is reporting an error, pressing the Alarm Mute Button will mute the audio alarm until another fault condition occurs. This button is also used as a bootload button for factory service in the unlikely event of a complete card failure. The bootload process is further described in pages 36-37, Service Information.
Page 34 8310/8321 User Manual ••• (V 1.0)
Reset Button
This button is used to restart both of the onboard processor s: the fan control processor and the communications processor. The communications processor requires approximately 30 seconds to restart and r e-establish network communications.
MFC-8310-N LEDs
The front edge of the MFC-8310-N, and the CFM-8310 in the frame door, have LED indicators for cooling module fan, alarm, and communication activity.
The CFM-8310 provides LED and Alarm switching controls to the front edge of the 8310 frame door. LED displays and descriptions are provided in the following table:
8310/8321 User Manual ••• (V 1.0) Page 35
Table 4. MFC-8310-N Controller Card LED Descri pt i ons
LED Color Location Display and Description
Alarm (MFC-8310-N)
Red DS1
When lit, an alarm condition is occurring in the frame.
Status OK (MFC-8310-N)
Green DS2
When lit, the fan control process is operating correctly.
Comm. Activity (MFC-8310-N)
Yellow DS3
When lit, the card is communicating within the frame.
Processor Red DS4
This LED flashes red briefly when the card is first powered up. If lit at any other time, this LED indicates that the communications processor is not running.
Error (MFC-8310-N)
Red DS5
This LED is lit when the MFC-8310-N card is first powered up and the card is booting up. The LED turns off once boot up is complete. If this LED is lit during normal operation, it indicates that the communications software is not running correctly. You must restart the processor by pressing the
RESET button. Transmitting (MFC-8310-N)
Green DS6
When lit, the MFC-8310-N card is transmitting
messages on the internal communications bus. Receiving (MFC-8310-N)
Yellow DS7
When lit, the MFC-8310-N card is receiving
messages via the internal bus. Fault
(CFM-8310)
Red
When lit, a SMPTE alarm condition is occurring in
the frame. Fan Fail
(CFM-8310)
Red
When lit, a fan on the frame door or PS-8300 is
stalled.
Power Supply (8310)
Green/Red
When lit Green, the PS-8300 is operating normally.
When flashing Red:
there is an output over or under voltage
condition on the PS-8300
there is no A/C; provided that the second
supply is operating normally
DashBoard and DashBoard Lite Control System Software
You can use the DashBoard or DashBoard Lite Control Systems to monitor and control your openGear
TM
frames and controller cards from a computer. The DashBoard software and manual can be
downloaded from the Cobalt Digital Inc. website.
SNMP Monitor i ng and Control
The MFC-8310-N Network Controller card provides optional support for remote monitoring and control of your frame and openGear
TM
cards using SNMP (Simple Network Management Pr otocol), which is compatible with many third-party monitoring and control tools. This section describes how to enable this feature and how to configure the SNMP software on the card.
Page 36 8310/8321 User Manual ••• (V 1.0)
Enabling SNMP
You must obtain a license key from Cobalt Digital Inc. to enable SNMP support. Use the following procedure to obtain your license key:
1. Request a license key from your distributor or at sales@cobaltdigital.com, quoting
the 8-character hardware-ID provided on the page.
2. Open the Frame Configuration Page for the frame using DashBoard. OR
Point your web browser to the IP address of the frame.
3. Select the tab titled SNMP Configuration.
If SNMP has not been enabled, this page will ask you to enter a license key.
4. Enter the license key in the field provided.
5. Click Submit.
After a valid license key has been entered, the frame displays the SNMP configuration page.
This completes the procedure to enable the SNMP agent on the frame.
Configuring SNMP
The SNMP agent on the frame will accept SNMP GET and SET requests on the default SNMP port (161), using SNMP version 1 or SNMP version 2c. The SNMP commands will send SNMP traps to one or more notification targets, with user-configurable address, port, and protocol version number.
Use the following procedure to configure your SNMP Agent:
1. Open the configuration page for the frame using DashBoard. OR
Point your web browser to the IP address of the frame.
2. Select the tab titled SNMP Configuration.
3. Set the required parameters as follows:
Read Community String Enter the SNMP password for GET requests.
Write Community String Enter the SNMP password for SET requests.
4. To add a trap/notification target, specify the following:
Target IP address  Enter the IP address to which traps should be sent.
Port number Enter the UDP port number to which traps should be sent.
SNMP version Enter the protocol version to be used for traps to this target.
Target community string Enter the community string.
5. Click Add to add the target to the list.
Operating
Tip
To remove a trap/notification target, select the target in the list, and click Delete.
6. Click the Submit button to configure the frame.
This completes the procedure to configure your SNMP Agent.
8310/8321 User Manual ••• (V 1.0) Page 37
Rear Support Bars and Brackets
Under normal conditions, mounting the frame to the front of the rack with four rack screws should be sufficient to carry the load, including the weight of accompanying cables. The optional FSB-8310 Rear Support Bars and Brackets are specifically engineered to compensate for extra load stress associated with certain applications, such as mobile truck installations, to also support the rear of the frame.
Figure 15. FSB-8310 Rear Support Bars and Brackets Diagram
Installing the Rear Support Bars and Brackets
Use the following procedure to install the FSB-8310 rear support bars and brackets:
1. The rear support bars can be attached to the openGear
TM
frame in six possible positions; refer to Figure 15. Choose the position that suits the cabinet depth that will give approximately a ½ inch (0.5") projection beyond the rear vertical mounting rails. Using four screws per bar, as shown in the illustration, fasten one bar to each side of the openGear
TM
frame.
2. Mount the openGear
TM
frame to the front rails of the rack cabinet using four rack
screws fastened through the front mounting flanges.
3. At the rear of the cabinet, slide the bracket slots over the rear of the support bars and
secure to the cabinet rear rails with two rack screws each.
This completes the procedure to install the FSB-8310 rear support bars and brackets.
Page 38 8310/8321 User Manual ••• (V 1.0)
8321 20-Slot Frame Setup
In This Chapter
This chapter provides information on setting up and using the 8321 series frame. The 8321 is a 2RU modular frame, designed to accommodate up to 20 openGear cards and support up to 10 high-density openGe ar fiber cards.
The following topics are discussed:
Rear Modules for the 8321 Series Frame
Cooling Features
Specifications for the 8321 Series Frames
8310/8321 User Manual ••• (V 1.0) Page 39
Rear Modules for the 8321 Series Frames
If your 8321 series frame was ordered with cards requiring Full Rear Modules or Split Rear Modules, the appropriate modules are installed at the factory or included with the cards. Blank Rear Modules (R2-BLANK) are installed when the slot does not have an openGear card installed. This helps to ensure proper frame cooling and ventilation.
Full Rear Module
The Full Rear Modules features a single card connector and can include up to 10 BNCs, or a combination of BNC, AES, and fiber optic connectors. Each module occupies two slots in the frame and the openGear card must be installed in an even slot number, such as slot 2 or 4. Up to 10 cards can be installed using this rear module type.
Figure 4.2 Full Rear Module — Ten BNC Connectors
Page 40 8310/8321 User Manual ••• (V 1.0)
Split Rear Module
This module features two card connectors and can include up to 10 BNCs, or a combination of BNC, AES, and fiber optic connectors. Each card connector is routed to a column of five BNCs. This module can only be used in a 8321 series frame. A Split Rear Module occupies two slots in the frame but provides connectors for two openGear cards. Up to 20 cards can be installed in the frame using this type of rear module.
Figure 4.3 Split Rear Module Ten BNC Connectors
8310/8321 User Manual ••• (V 1.0) Page 41
Cooling Features
The 8321 series frames come standard with the Cooling Fan Module installed as original equipment from the factory. However, if you need to replace the ventilation in a 8321 series frame door, the optional CFM-8321 Cooling Fan Module is available as a field installation kit.
Cooling Fan Functions and User Controls
The 8321 series frames includes Fault LEDs and the Alarm mute button on the front of the frame door. For details on the LED functions, refer to Table 2.2. For oper a tional details for your MFC­8300 series controller card, refer to the MFC-8300 Series User Manual.
Figure 4.5 8321 Series Frame Door Features
Replacing the CFM-8321 Cooling Fan Module
This section includes instructions on installing the CFM-8321 Cooling Fan Module Replacement Kit. The CFM-8321 Cooling Fan Module Replacement Kit includes the fan board and filter pre­installed in a new 8321 series frame door.
Use the following procedure to replace the CFM-8321 Cooling Fan Module:
1. Carefully remove the door from the frame as follows:
Gently pull the side door tabs towards the center of the door, releasing the door from
the frame. The door extender arms prevent the door from falling.
Using both hands, pull the door towards you.
Tilt the door upward until the arms match the cutout.
Gently push the door extender arms in and over the retaining bolts and unhook from
the frame.
2. Remove the door and place it on a clean, flat, static-free surface
3. On the new frame door of the CFM-8321 Cooling Fan Module, verify that the Alarm Mute button pushes in and out without binding.
This completes the procedure for replacing the CFM-8321 Cooling Fan Module.
Page 42 8310/8321 User Manual ••• (V 1.0)
Specifications for the 8321 Series Frames
This section includes the Technical Specifications table for the 8321 series frame.
Table 4.5 8321 Series Frame Technical Specifications
Category Parameter Specification
Input 100-240VAC, 47-63Hz, 190W Output 1 +12V, ± 10%, 0.5A - 12.5A Output 2 -7.5V, ± 10%, 0A - 1.5A
PS-8300
Power Supply
Total
Sum of both outputs not to exceed 150W
m
aximum
Height 2RU 3.5" (8.89cm) Width 19" (48.26cm) Depth 17" (43.18cm)
Rack Frame
Mechanical
Weight, with 1 PS-8300
13lbs (5.90kg)
N
umber of Slots 20 Max Power: +12V Rail 2.0A (24W) Max Power: -7.5V Rail 0.2A (1.5W)
Frame Card Slots
Total
120W, total power consumption not to exceed 24W maximum per card slot
Max Power: +12V Rail 1.5A (18W) Max Power: -7.5V Rail 0.2A (1.5W)
Frame Controller
and Fans
Total 19.5W maximum Max Power: +12V Rail
0.2A (2.4W)
Max Power: -7.5V Rail
0.2A (1.5W)
Comm I/O
Controller
Total
3.9W maximum
N
umber of Inputs
2 looping
Level
1Vpp nominal
Signal
Analog video sync (black burst or tri-
l
evel), or AES/EBU DARS
Impedance
75ohm terminating
Return Loss
>30dB to 30MHz
Reference Inputs
Max DC on Ref Input
±1V
Ambient temperature range
0 ºC to 40 ºC
Environmental
Humidity, non condensing <95%
Specifications are subject to change without notice.
8310/8321 User Manual ••• (V 1.0) Page 43
Service Information
In This Chapter
This chapter contains the following sections:
Troubleshooting Checklist
Frame Controller Alarm Mute/Bootload Button
Warranty and Repair Policy
Troubleshooting Checklist
Routine maintenance to this openGearTM product is not required. In the event of problems with your 8310, the following basic troubleshooting checklist may help identify the source of the problem. If the frame still does not appear to be working properly after checking all possible causes, please contact your openGear
TM
products distributor, or the Technical Support department at the numbers listed under
the Contact Us section at the end of this manual.
1. Visual Review – Performing a quick visual check may reveal many problems, such
as connectors not properly seated or loose cables. Check the card, the frame, and any associated peripheral equipment for signs of trouble.
2. Power Check – Check the power indicator LED on the distribution frame front panel
for the presence of power. If the power LED is not illuminated, verify that the power cable is connected to a power source and that power is available at the power main. Confirm that the power supplies are fully seated in their slots. If the power LED is still not illuminated, replace the power supply with one that is verified to work.
3. Input Signal Status – Verify that source equipment is operating correctly and that a
valid signal is being supplied.
4. Output Signal Path – Verify that destination equipment is operating correctly and
receiving a valid signal.
5. Unit Exchange – Exchanging a suspect unit with a unit that is known to be working
correctly is an efficient method for localizing problems to individual units.
Frame Controller Alarm Mute/Bootload Button
In the unlikely event of a complete card failure, you may be instructed by a Cobalt Digital Inc. Technical Support specialist to perform a complete software reload on the MFC-8310 frame controller card.
Page 44 8310/8321 User Manual ••• (V 1.0)
Use the following procedure to reload the software:
1. Eject the card.
2. Press and hold the Alarm Mute/Bootload button, while re-inserting the card into the frame.
3. Release the button.
The STATUS OK LED will flash GREEN while the card is waiting for a new software load. If a new software load is not sent to the card within 60 seconds, the card will attempt to restart
with it's last operational software load.
Software loads can be sent to the Network Controller Card via the connection to the openBUS on the rear of the frame.
8310/8321 User Manual ••• (V 1.0) Page 45
Warranty and Repair Policy
Cobalt Digital Inc. Limited Warranty
This product is warranted to be free from defects in material and workmanship for a period of five (5) years from the date of shipment to the original purchaser, except that 4000, 5000, 6000, 8000 series power supplies, and Dolby
®
modules (where applicable) are warranted to be free from defects in
material and workmanship for a period of one (1) year. Cobalt Digital Inc.'s (“Cobalt”) sole obligation under this warranty shall be limited to, at its option, (i)
the repair or (ii) replacement of the product, and the determination of whether a defect is covered under this limited warranty shall be made at the sole discretion of Cobalt.
This limited warranty applies only to the original end-purchaser of the product, and is not assignable or transferrable therefrom. This warranty is limited to defects in material and workmanship, and shall not apply to acts of God, accidents, or negligence on behalf of the purchaser, and shall be voided upon the misuse, abuse, alteration, or modification of the product. Only Cobalt authorized factory representatives are authorized to make repairs to the product, and any unauthorized attempt to repair this product shall immediately void the warranty. Please contact Cobalt Technical Support for more information.
To facilitate the resolution of warranty related issues, Cobalt recommends registering the product by completing and returning a product registration form. In the event of a warrantable defect, the purchaser shall notify Cobalt with a description of the problem, and Cobalt shall provide the purchaser with a Return Material Authorization (“RMA”). For return, defective products should be double boxed, and sufficiently protected, in the original packaging, or equivalent, and shipped to the Cobalt Factory Service Center, postage prepaid and insured for the purchase price. The purchaser should include the RMA number, description of the problem encountered, date purchased, name of dealer purchased from, and serial number with the shipment.
Cobalt Digital Inc. Factory Service Center 2406 E. University Avenue Office: (217) 344-1243 Urbana, IL 61802 USA Fax: (217) 344-1245 www.cobaltdigital.com Email: info@cobaltdigital.com THIS LIMITED WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON COBALT'S PART. ANY SOFTWARE PROVIDED WITH, OR FOR USE WITH, THE PRODUCT IS PROVIDED AS IS. THE BUYER OF THE PRODUCT ACKNOWLEDGES THAT NO OTHER REPRESENTATIONS WERE MADE OR RELIED UPON WITH RESPECT TO THE QUALITY AND FUNCTION OF THE GOODS HEREIN SOLD. COBALT PRODUCTS ARE NOT AUTHORIZED FOR USE IN LIFE SUPPORT APPLICATIONS.
COBALT'S LIABILITY, WHETHER IN CONTRACT, TORT, WARRANTY, OR OTHERWISE, IS LIMITED TO THE REPAIR OR REPLACEMENT, AT ITS OPTION, OF ANY DEFECTIVE PRODUCT, AND SHALL IN NO EVENT INCLUDE SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING LOST PROFITS), EVEN IF IT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Page 46 8310/8321 User Manual ••• (V 1.0)
Ordering Information
In This Chapter
Your 8310 openGearTM Two Rack Unit Frame and Power Supply (PS-8300) is a part of the openGear
TM
family of products. We offer a full line of openGearTM terminal equipment including distribution, conversion, monitoring, synchronizers, encoders, decoder s , AES, keyers, control switches, a s well a s analog audio and video products.
Standard Equipment
8310-C Digital Products Frame and Power Supply with Cooling Fans
(2RU, holds 10 cards)
8321-C Digital Products Frame and Power Supply with Cooling Fans
(2RU, holds 20 cards)
8310-C-BNC Digital Products Frame and Power Supply with fixed 100-BNC Rear
Module and Cooling Fans. (2RU, holds 10 cards)
8310-UM Multi-Definition Digital Products Frame & Power Supply (PS-8300) Owner’s
Manual
Optional Equipment
8310-UM Multi-Definition Digital Products Frame & Power Supply (PS-8300) Owner’s
Manual (additional Owners Manual)
PS-8300 openGear
TM
Power Supply, 150W (redundancy option power supply for Cobalt
Digital Inc. 8310 series 2RU digital product frames)
MFC-8310-N openGear
TM
2RU Frame Controller with Network Interface
(upgrade controller card with Ethernet communication capability)
MFC-8320-N openGear
TM
2RU Frame Controller with Network Interface (upgrade controller card with Ethernet communication capability for use with 8310 and 8321 frames)
8310/8321 User Manual ••• (V 1.0) Page 47
Notes:
Page 48 8310/8321 User Manual ••• (V 1.0)
Contact Us
Contact Cobalt Digital Inc.
General Business Office and Technical Support
217.344.1243
PHONE
Fax
217.344.1245
General Information
Info@cobaltdigital.com
E-MAIL
Sales Information
Sales@cobaltdigital.com
Cobalt Digital Inc.
2406 East University Avenue Urbana, IL 61802 USA
POSTAL
SERVICE
Visit us at the Cobalt Digital Inc. website.
http://www.cobaltdigital.com/
Online catalog
Related products and full product lines
Trade show information
Dealer information
Cobalt Digital Inc. news
Loading...