Cobalt Digital 9910DA-4Q-3G-RCK Users Guide

Page 1
9910DA-4Q-3G-RCK
9910DA-4Q-3G-RCK
9910DA-4Q-3G
9910DA-4Q-3G
Quad-Channel Multi-Rate DA
• 9910DA-4Q-3G-RCK (Reclocking)
• 9910DA-4Q-3G (Non-Reclocking)
Product Manual
Cobalt Digital Inc.
2506 Galen Drive Champaign, IL 61821 Voice 217.344.1243 • Fax 217.344.1245 www.cobaltdigital.com
9910DA-4Q-3G-OM (V1.3)
Page 2
Copyright
©Copyright 2015, Cobalt Digital Inc. All Rights Reserved.
Duplication or distribution of this manual and any information contained within is strictly prohibited without the express written permission of Coba lt Digital Inc. This manual and a ny information contained within, may not be re produced, distribute d, or transmitted in any form, or by any means, for any purpose, without the express written permission of Cobalt Digital Inc. Reproduction or reverse engineering of software used in this device is prohibited.
Disclaimer
The information in this document has been carefully examined and is believed to be entirely reliable. However, no responsibility is assumed for inaccuracies. Furthermore, C obalt Digit al Inc. res erves the right to ma ke changes to any pro ducts herein to improve readability, function, or design. Cobalt Digital Inc. does not assume any liability arising out of the application or use of any product or circuit described herein.
Trademark Information
Cobalt® is a registered trademark of Cobalt Digital Inc. Compass openGear
®
is a registered trademark of Cobalt Digital Inc.
®
is a registered trademark of Ross Video Limited. DashBoard™ is a trademark of Ross Video Limited.
Congratulations on choosing the Cobalt Output Crosspoint . (This manual c overs both th e 9910DA-4Q -3G-RCK Quad -Channel Multi-Rate Re clocking DA with x4 Output Crosspoint (Reclocking) and the 9910DA-4Q-3G Quad-Channel Multi-Rate Reclocking DA with x4 Output Cr osspoint (Non-Reclocking ) cards. The 9910DA-4Q-3G car ds are part of a full line of modular processing and conversion gear for broadcast TV environments. The Cobalt Digital Inc. line includes video decoders and encode rs, audio embedders and de-embedde rs, distribution amplifiers , format converters, remote control systems and much more. Should you have questions pertaining to the installation or operation of your card, please contact us at the contact information on the front cover.
®
9910DA-4Q-3G Quad -Channel Multi-Rate Rec locking DA with x4
Manual No.: 9910DA-4Q-3G-OM Document Version: V1.3 Release Date: April 23, 2015 Applicable for
Firmware Version
1.0.5
(or greater): Description of
- Correction of errata (max power)
product/manual changes:
9910DA-4Q-3G-OM (V1.3)
Page 3
Table of Contents
Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Overview ................................................................................................................ 1-1
Manual Conventions............................................................................................... 1-2
Warnings, Cautions, and Notes .................................................................. 1-2
Labeling Symbol Definitions...................................................................... 1-3
Safety Summary ..................................................................................................... 1-3
Warnings..................................................................................................... 1-3
Cautions...................................................................................................... 1-3
9910DA-4Q-3G Functional Description ................................................................ 1-4
9910DA-4Q-3G Rear I/O Modules............................................................ 1-5
Technical Specifications......................................................................................... 1-6
Warranty and Service Information ......................................................................... 1-7
Cobalt Digital Inc. Limited Warranty......................................................... 1-7
Contact Cobalt Digital Inc...................................................................................... 1-8
Chapter 2 Installation and Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Overview ................................................................................................................ 2-1
Card-Edge Switches and Monitoring ..................................................................... 2-1
Input/Output Routing With Card in Card-Edge (Local) Control Mode........ 2-2
Installing the 9910DA-4Q-3G Into a Frame Slot................................................... 2-4
Installing a Rear I/O Module.................................................................................. 2-5
9910DA-4Q-3G Rear I/O Modules............................................................ 2-7
Chapter 3 Operating Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Overview ................................................................................................................ 3-1
Accessing the 9910DA-4Q-3G Card via Remote Control ..................................... 3-1
Accessing the 9910DA-4Q-3G Card Using DashBoard........................ 3-1
Checking 9910DA-4Q-3G Card Information and Status ....................................... 3-2
Card-Edge Controls and Indicators ........................................................................ 3-2
9910DA-4Q-3G Function Menu List and Descriptions......................................... 3-3
Output Source Crosspoint Control ............................................................ 3-3
Reclock Outputs Control ........................................................................... 3-5
Presets ........................................................................................................ 3-5
Troubleshooting...................................................................................................... 3-6
Basic Troubleshooting Checks................................................................... 3-6
Troubleshooting Network/Remote Control Errors..................................... 3-7
In Case of Problems.................................................................................... 3-7
9910DA-4Q-3G-OM (V1.3) 9910DA-4Q-3G PRODUCT MANUAL i
Page 4
This page intentionally blank
ii 9910DA-4Q-3G PRODUCT MANUAL 9910DA-4Q-3G-OM (V1.3)
Page 5

Overview

Chapter 1

Chapter 1 Introduction

This manual provides installati on and o per at ing instr uct ions for the 9910DA-4Q-3G Quad-Channel Multi-Rate Reclocking DA with x4 Output Crosspoint cards (also referred to herein as the 9910DA-4Q-3G).
Note: This manual is applicable for both the 9910DA-4Q-3G-RCK Quad-Channel
Multi-Rate Reclocking DA with x4 Output Crosspoint (Reclocking) and the 9910DA-4Q-3G Quad-Channel Multi-Rate DA with x4 Output Crosspoint (Non-Reclocking) versions of this card. Reclocking functions and specifications listed in this manual are not applicable to 9910DA-4Q-3G. In all other aspects, both versions function identically as described in this manual unless otherwise noted.
This manual consists of the following chapters:
Chapter 1, Introduction – Provides i nformation a bout this manua l
and what is covered. Als o pr ovi des general information re gar di ng the 9910DA-4Q-3G.
Chapter 2, Installation and Setup” – Provides instructions for
installing the 9910DA-4Q-3G in a frame, and optionally installing a 9910DA-4Q-3G Rear I/O Module.
Chapter 3, Operating Instructions” – Provides overviews of
operating controls and instructions for using the 9910DA-4Q-3G.
This chapter contains the following information:
Manual Conventions (p. 1-2)
Manual Conventions (p. 1-2)
Safety Summary (p. 1-3)
9910DA-4Q-3G Functional Description (p. 1-4)
Technical Specifications (p. 1-6)
Warranty and Service Information (p. 1 - 7)
Contac t Cobalt Digital Inc. (p. 1-8)
9910DA -4Q- 3G- OM (V1. 3) 9910DA-4Q-3G PRODUCT MANUAL 1-1
Page 6
1 Manual Conventions

Manual Conventions

In this manual, display messages and connectors are shown using the exact name shown on the 9910DA-4Q-3G it sel f ( fo r ex ample , connector names are shown like this:
In this manual, the terms below are applicable as follows:
9910DA-4Q-3G-RCK refers to the 9910DA-4Q-3G Quad-Channel
Multi-Rate Reclocking DA with x4 Output Crosspoint card.
9910DA-4Q-3G refers to the 9910DA-4Q-3G Quad-Channel
Multi-Rate DA with x4 Output Crosspoint (Non-Reclocking) card.
SDI IN A)

Warnings, Cautions, and Notes

Certain items in this manual are highlighted by special messages. The definitions are provided below.
Warnings
Warning messages indicate a possible hazard which, if not avoided, could result in personal injury or death.
Cautions
Caution messages indicate a problem or incorrect practice which, if not avoided, could result in improper operation or damage to the product.
Frame refers to the HPF-9000, OG3-FR, 8321, or similar 20-slot
frame that houses Cobalt
Device and/or Card refers to a Cobalt
System and/or Video System refers to the mix of interconnected
®
or other cards.
®
or other card.
production and termi nal e quipment in which t he 991 0DA-4Q-3G and other cards operate.
Notes
Notes pro vide suppl emental information to the accompanying text. Notes typically precede the text to which they apply.
1-2 9910DA - 4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Page 7
Introduction Safety Summary

Labeling Symbol Definitions

Important note regarding product usage. Failure to observe may result in unexpected or incorrect operation.
Electronic device or assembly is susceptible to damage from an ESD event. Handle only using appropriate ESD prevention practices.
If ESD wrist strap is not available, handle card only by edges and avoid contact with any connectors or components.
Symbol (WEEE 2002/96/EC) For product disposal, ensure the following:
Do not dispose of this product as unsorted municipal waste.
Collect this product separately.
Use collection and return systems available to you.

Safety Summary

Warnings

! WARNING !

Cautions

CAUTION
CAUTION
CAUTION
CAUTION
T o re duce risk of electr ic shock do not remove line voltage service barrier cover on frame equipment containing an AC power supply. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
This device is intended for environmentally controlled use only in appropriate video terminal equipment operating environments.
This product is intended to be a compo nent produc t of a n open Gea r® or equiva lent frame . Refer to the frame Product Manual for important safety instructions regarding the proper installation and safe operation of the frame as well as its component products.
If required, make certain Rear I/O Module(s) is installed before installing the 9910DA-4Q-3G into the frame slot. Damage to card and/or Rear I/O Module can occur if module installation is attempted with card already installed in slot.
If card resists fully engaging in rear I/O mod ule mating connec tor, check for alignment and proper insertion in slot tracks. Damage to card and/or rear I/O module may occur if improper card insertion is attempted.
9910DA-4Q-3G-OM (V1. 3) 9910DA- 4 Q-3G P RODU CT MA N UAL 1-3
Page 8
1 9910DA-4Q-3G Functional Description

9910DA-4Q-3G Functional Description

Figure 1-1 shows a fu nction al bl ock di agram o f the 9910DA-4Q- 3G. With the appropriate rear module, the 9910DA-4Q-3G can provide up to 16 DA video outputs.
Input/Output Formats
The 9910DA-4Q-3G provides the following inputs and outputs:
Inputs:
3G/HD/SD-SDI IN (A-D) four coaxial 3G/HD/SD-SDI / ASI video
inputs
Outputs:
3G/HD/SD-SDI IN (1-16) up to 16 coaxial 3G/HD/SD-SDI / ASI
video outputs. All outputs are non-inverting and can be used as SDI or ASI outputs.
Remote/Local Control
The 9910DA-4Q-3G is equipped with card-edge controls that allow limited control such as distribution mode. When card-edge control is enabled, DashBoard remote control is disabled (and vice-versa).
Distribution Modes Select
The 9910DA-4Q-3G uses four DA quadrants (each consisting of a 1x4 non-inverting DA). Using these four quadrants fed by an input-sourcing crosspoint, the card provides multiple dist ri bution modes, allowing the card’s distribution potential to be maximized as desired. While the DashBoard control allows fully flexible input crosspoint sourcing, the basic typically used modes are:
Quad-Channel 1x4 DA
Dual-Channel 1x8 DA
Single-Channel 1x16 DA
Reclock Select (9910DA-4Q-3G-RCK Only)
Reclocking can be individually enabled or disabled for any of the 4-output card DA quadrants. (As shown in Figure 1-1, the card applies its four inputs to an output crosspoint block which in turn feeds up to four quad DA blocks, each with selectable reclock enable/disable.)
1-4 9910DA - 4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Page 9
Introduction 9910DA-4Q-3G Functional Description
Output
Crosspoint
/Mux
3G/HD/SD-SDI / ASI
3G/HD/SD-SDI / ASI
3G/HD/SD-SDI / ASI
3G/HD/SD-SDI / ASI
IN A
IN B
IN C
IN D
EQ
EQ
EQ
EQ
X
Reclock*
Reclock*
Reclock*
Reclock*
DA
DA
DA
DA
1
3G/HD/SD-SDI /
2
ASI OUT (1-4)
3 4
5
3G/HD/SD-SDI /
6
ASI OUT (5-8)
7 8
9
3G/HD/SD-SDI /
10
ASI OUT (9-12)
11 12
13
3G/HD/SD-SDI /
14
ASI OUT (13-16)
15 16
* 9910DA-4Q-3G-RCK ONLY
Figure 1-1 9910DA-4Q-3G Functional Block Diagram

9910DA-4Q-3G Rear I/O Modules

The 9910DA-4Q-3G physically in te rfaces to system video connecti ons at the rear of its frame using a Rear I/O Module. The full assortment of 9910DA-4Q-3G Rear I/O Modules is shown and described in 9910DA-4Q-3G Rear I/O Modules (p. 2-7) in Ch apter 2, Installation and Setup”.
BASIC CROSSPOINT MODES
Quad 1x4 Dual 1x8 Single 1x16
A
B
C
D
A
B
A
9910DA-4Q-3G-OM (V1. 3) 9910DA- 4 Q-3G P RODU CT MA N UAL 1-5
Page 10
1 Technical Specifications

Technical Specifications

Table 1-1 lists the technical specifications for the 9910DA-4Q-3G-RCK Quad-Channel Multi-Rate Reclocking DA with x4 Output Crosspoint and 9910DA-4Q-3G Quad-Channel Multi-Rate DA with x4 Output Crosspoint (Non-Reclocking) cards.
Table 1-1 Technical Specifications
Item Characteristic
Part number, nomenclature 9910DA-4Q-3G-RCK Quad-Channel Multi-Rate Reclocking DA
with x4 Output Crosspoint (Reclocking) card
9910DA-4Q-3G Quad-Channel Multi-Rate DA with x4 Output Crosspoint (Non-Reclocki ng) card
Installation/usage environment Intended for installation and usage in frame meeting openGear
modular system definition. Power consumption < 3 Watts maximum Installation Density Up to 20 cards per 20-slot frame Environmental:
Operating temperature: Relative humidity (operating or storage):
32° – 104° F (0° – 40° C)
< 95%, non-condensing Frame communication 10/100 Mbps Ethernet with Auto-MDIX. Indicators Card edge display and indicators as follows:
Status/Error LED indicator
Input Presence LED indicators
3G/HD/SD-SDI / ASI Inputs (4) 75 coaxial inputs (A thru D)
SDI Formats Supported: SMPTE 259M, SMPTE 292M, SMPTE 424M
SDI Return Loss: >15 dB up to 1.485 GHz; >10 dB up to
2.970 GHz
Receive Performance (Cable Length; Belden 1694A)
3G/HD/SD-SDI / ASI Outputs (4x4) 75 coaxial outputs (16 total). Each group of 4 outputs can
3 Gbps: 120m
1.485 Gbps: 160m 143-360 Mbps: 400m
be crosspoint connected to inputs A thru D. Signal Level: 800 mV nominal Return Loss: >15 dB at 5 MHz - 1.485 GHz Jitter (wideband): HD
< 0.2 UI
1-6 9910DA - 4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Page 11
Introduction Warranty and Service Information

Warranty and Service Information

Cobalt Digital Inc. Limited Warranty

This product is warranted to be free from defects in material and workmanship for a period of five (5) years from the date of shipment to the original purchaser, except that 4000, 5000, 6000, 8000 series power supplies, and Dolby material and workmanship for a period of one (1) year.
Cobalt Digital Inc.'s (Cobalt) sole obligation under this warranty sh all be limited to, at its option, (i) the repair or (ii) replacement of the produc t, and the det ermination of whether a defect is covered under this limited warranty shall be made at the sole discretion of Cobalt.
This limited warrant y appl ies on ly t o the origi nal end-pu rchaser of the produ ct, and i s not assign able o r transferrable therefrom. This warr ant y i s li mited to defects in material and work ma nship, and shall not apply to acts of God, accidents, or negligence on behalf of the purchaser, and shall be voided upon the misuse, abuse, alteration, or modification of the product. Only Cobalt authorized factory representatives are authorized to make repairs to the product, and any unauthorized attempt to repair this product shall immediately void the warranty. Please contact Cobalt Technical Support for more information.
®
modules (where applicable) are warranted to be free from defects in
To facilitate the resolut ion of warranty related issues, Cobalt recommends registering the product by completing and returning a product registration form. In the event of a warrantable defect, the purchaser shall notify Cobalt with a descripti on of t he p r oble m, an d Cobalt shall provide the pur ch aser with a Re turn Mate rial Auth oriz ation (“RMA”). For retu rn, defective product s should be double boxed, and sufficiently protecte d, in the original packa ging, or equivalent, a nd shipped to the Coba lt Factory Service Center, postage prepaid and insured for the purchase price. The purchaser should include the RMA number, description of the problem encountered, date purchased, name of dealer purchased from, and serial number with the shipment.
Cobalt Digital Inc. Factory Service Center
2506 Galen Drive Office: (217) 344-1243 Champaign, IL 61821 USA Fax: (217) 344-1245 www.cobaltdigital.com Email: info@cobaltdigital.com
THIS LIMITED WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON COBALT'S PART. ANY SOFTWARE PROVIDED WITH, OR FOR USE WI TH, THE PRODUCT IS PROVIDED AS IS. THE BUYER OF THE PRODUCT ACKNOWLEDGES THAT NO OTHER REPRESENTATIONS WERE MADE OR RELIED UPON WITH RESPECT TO THE QUALITY AND FUNCTION OF THE GOODS HEREIN SOLD. COBALT PRODUCTS ARE NOT AUTHORIZED FOR USE IN LIFE SUPPORT APPLICATIONS .
COBALT'S LIABILITY, WHETHER IN CONTRACT, TORT, WAR RANTY, OR OTHERWISE, IS LIMITED TO THE REPAIR OR REPLACEMENT, AT ITS OPTION, OF ANY DEFECTIVE PRODUCT, AND SHALL IN NO EVENT INCLUDE SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING LOST PROFITS), EVEN IF IT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
9910DA-4Q-3G-OM (V1. 3) 9910DA- 4 Q-3G P RODU CT MA N UAL 1-7
Page 12
1 Contact Cobalt Digital Inc.

Contact Cobalt Digital Inc.

Feel free to contact our thorough and professional suppo rt repr es entatives for any of the following:
Name and address of your local dealer
Product information and pricing
Technical support
Upcoming trade show informatio n
Phone: (217) 344-1243 Fax: (217) 344-1245 Web: www.cobaltdigital.com General Information: info@cobaltdigital.com Technical Support: support@cobaltdigital.com
1-8 9910DA - 4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Page 13

Chapter 2 Installation and Setup

Overview

This chapter contains the following information:
Card-Edge Switches and Monitoring (p. 2-1)
Installing the 9910DA-4Q-3G Into a Frame Slot (p. 2-4)
Installing a Rear I/O Module (p. 2-5)

Card-Edge Switches and Monitoring

CAUTION
This device contains semiconductor devices which are susceptible to serious damage from Electrostatic Discharge (ESD). ESD damage may not be immediately apparent and can affect the long-term reliability of the device.
Chapter 2
Always use proper ESD handling precautions and equipment when working on circuit boards and related equipment.
Figure 2-1 shows and describes the card-edge switches which can be used to provide li mited card control without requiring a remote control connection (local control).
9910DA -4Q- 3G- OM (V1. 3) 9910DA-4Q-3G PRODUCT MANUAL 2-1
Page 14
2 Card-Edge Switches and Monitoring
Card-Edge Switch
PWR
COM
ERR
IN A
IN B
IN C
IN D
SW1
SW2
SW3
UP (off)
DOWN (on)
SW1 S W2 SW3 Mode
UP DOWN
DOWN DOWN Quad 1x4 DA (uses IN A thru IN D) DOWN UP Dual 1x8 DA (uses IN A and IN B) UP Single 1x16 DA (uses IN A)
Note: • When using card-edge control, DA modes are limited to inputs listed.
When using remote control, inputs to the four quad DA blocks can be sourced as desired and as supported by rear I/O module connector count.
When using card-edge control, displayed DashBoard routing settings may not reflect actual fixed card-edge routing.
SW4 is reser ved.
Setting switch SW1 to local locks out remote control of the card.
SW4
——
Remote Control Local (card-edge) Control
9910DA-4Q
Status/Error
Indicators
Input Format
Indicators
Figure 2-1 9910DA-4Q-3G Card-Edge Switches

Input/Output Routing With Card in Card-Edge (Local) Control Mode

When the 9910DA-4Q-3G is set for car d-edge (local) cont rol, only fixed quad 1x4, dual 1x8, and single 1x16 routing is available using dedicated input and output ports. When using any of these fixed modes, the rear I/O module used must be compatible with the mode. (See 9910DA-4Q-3G Rear I/O Modules (p. 2-7) for rear module detai ls. ) Figure 2-2 shows the fixed routi ng ava il abl e using local control and compatible rear modules.
2-2 9910DA - 4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Page 15
Installation and Setup Card-Edge Switches and Monitoring
In card-edge (local) control mode, I/O routing is fixed to certain input and output ports. Also, when a mode is selected that uses less than the four maximum inputs (SD I IN A th ru SDI IN D), only certain inputs are available.
The figure below shows I/O routing for the three fixed card-edge DA modes for various rear modules.
Quad 1x4
A
SDI IN A I/O Routing Path
A
Dual 1x8
A
B
B
SDI IN A I/O Routing Path
SDI IN A I/O Routing Path
C
SDI IN A I/O Routing Path
D
Not available
X
A A
B B
B
C
D
A
C
B
D
RM20-9910-4Q-B
X X
A
B
A
B
RM20-9910-4Q-A
Single 1x16
A
RM20-9910-4Q-B
X
X X
A A
A A
A
A A
RM20-9910-4Q-D
A
RM20-9910-4Q-B
Figure 2-2 Input/Output Routing (Card-Edge (Local) Control Mode)
9910DA-4Q-3G-OM (V1. 3) 9910DA- 4 Q-3G P RODU CT MA N UAL 2-3
Page 16
2 Installing the 9910DA-4Q-3G Into a Frame Slot

Installing the 9910DA-4Q-3G Into a Frame Slot

CAUTION
This device contains semiconductor devices which are susceptible to serious damage from Electrostatic Discharge (ESD). ESD damage may not be immediately apparent and can affect the long-term reliability of the device.
Avoid handling circuit boards in high static environments such as carpeted areas, and when wearing synthetic fiber clothing. Always use proper ESD handling precautions and equipment when working on circuit boards and related equipment.
Note: If installing the 9910DA-4Q-3G in a slot with no rear I/O module, a Rear
I/O Module is required before cabling can be connected. Refer to Installing a
Rear I/O Module (p. 2-5) for rear I/O module installation procedure.
CAUTION
If required, make certain Rear I/O Module(s) is installed before installing the 9910DA-4Q-3G into the frame slot. Damage to card and/or Rear I/O Module can occur if module installation is attempted with card already installed in slot.
Note: Check the packaging in which the 9910DA-4Q-3G was shipped for any extra
items such as a Rear I/O Module connection label. In some cases, this label is shipped with the card and to be installed on the Rear I/O connector bank corresponding to the slot location of the card.
Install the 9910DA-4Q-3G into a frame slot as follows:
1. Determine the slot in which the 9910D A-4Q-3G is to be installed.
2. Open the frame front access panel.
3. While holding the card by the card edges, align the card such that the
plastic ejector tab is on the bottom.
4. Align the card with the top and bottom guides of the slot in which the
card is being installed.
5. Gradually slide the card into the slot. When resistance is noticed, g ently
continue pushing the card until its rear printed circuit edge terminals engage fully into the rear I/O module mating connector.
CAUTION
If card resists fully engaging in rear I/O module mating connector, check for alignment and proper insertion in slot tracks. Damage to card and/or rear I/O module may occur if improper card insertion is attempted.
2-4 9910DA - 4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Page 17
Installation and Setup Installing a Rear I/O Module
6. Verify that the card is fully engaged in rear I/O module mating
connector.
7. Close the frame front access panel.
8. Connect the input and output cables as shown in 9910DA-4Q-3G Rear I/
O Modules (p. 2-7).
9. Repeat steps 1 through 8 for other 9910DA-4Q-3G cards.
Note: To remove a card, press down on the ejector tab to unseat the card from the
rear I/O module mating connector. Evenly draw the card from its slot.
Note: If installing a card in a frame already equipped for, and connected to
DashBoard, no network setup is required for the card. The card will be discovered by DashBoard and be ready for use.

Installing a Rear I/O Module

Note: This procedure is applicable only if a Rear I/O Module is not currently
installed in the slot where the 9910DA-4Q-3G is to be installed.
If installing the 9910DA-4Q-3G in a slot already equipped with a suitable I/O module, omit this procedure.
Install a Rear I/O Module as follows:
1. On the frame, determine the slot in which the 9910DA-4Q-3G is to be
installed.
2. In the mounting area corresponding to the slot location, install
Rear I/O Module as shown in Figure 2-3.
9910DA-4Q-3G-OM (V1. 3) 9910DA- 4 Q-3G P RODU CT MA N UAL 2-5
Page 18
2 Installing a Rear I/O Module
Align and engage mounting tab on Rear I/O Module with the module seating slot
1
on rear of frame chassis.
DSCN3483A.JPG
Hold top of Rear I/O Module flush against frame chassis and start the captive screw.
2
Lightly tighten captive screw.
DSCN3487A.JPG
Figure 2-3 Rear I/O Module Installation
2-6 9910DA - 4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Page 19
Installation and Setup Installing a Rear I/O Module

9910DA-4Q-3G Rear I/O Modules

Table 2-1 shows and describes the full assortment of Rear I/O Modules specifical l y for use with the 9910DA-4Q-3G cards.
Table 2-1 9910DA-4Q-3G Rear I/O Modules
9910DA-4Q-3G Rear I/O Module Description
Note: Rear I/O Module output designations here correlate to output numbers for four DA quadrants as shown in the
card block diagram (for example, SDI OUT 3 in diagrams below is tied to (driven from) DA quadrant SDI Out (1-4) in the block diagram; SDI OUT 5 in diagrams below is tied to (driven from) DA quadrant SDI Out (5-8) in the block diagram, and so on).
As such, SDI outputs within a quadrant group can only be sourced from a particular input at one time (for example, if the card is set to feed SDI IN A to quadrant SDI Out (1-4), the rear module outputs 1 thru 4 will all output SDI IN A). Dissimilar inputs cannot be routed within a quadrant group (for example, SDI OUT 1 sourced from SDI IN A and SDI OUT 2 sourced from SDI IN B).
RM20-9910-4Q-A Provides the following connections:
Two SDI/ASI video input BNCs (SDI IN A and SDI IN B)
Eight DA outputs:
SDI OUT 3 / 4 SDI OUT 5 / 7 SDI OUT 11 / 12 SDI OUT 13 / 14
RM20-9910-4Q-B Provides the following connections:
Four SDI/ASI video inputs (SDI IN A thru SDI IN D)
16 DA outputs (SDI OUT 1 thru SDI OUT 16)
Note: Available equipped with High-Density BNC
(HDBNC) or DIN1.0/2.3 connectors as: RM20-9910-4Q-B-HDBNC or RM20-9910-4Q-B-DIN, respectively.
9910DA-4Q-3G-OM (V1. 3) 9910DA- 4 Q-3G P RODU CT MA N UAL 2-7
Page 20
2 Installing a Rear I/O Module
Table 2-1 9910DA-4Q-3G Rear I/O Modules — continued
9910DA-4Q-3G Rear I/O Module Description RM20-9910-4Q-C Provides the followin g conne cti on s:
Three SDI/ASI video inputs (SDI IN A thru SDI IN C)
Seven DA outputs:
SDI OUT 4 SDI OUT 5 / 7 SDI OUT 11 / 12 SDI OUT 13 / 14
RM20-9910-4Q-D Provides the followin g conne cti on s:
One SDI/ASI video inputs (SDI IN A)
Nine DA outputs:
SDI OUT 3 / 4 SDI OUT 5, / 7 / 8 SDI OUT 11 / 12 SDI OUT 13 / 14
2-8 9910DA - 4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Page 21
Installation and Setup Installing a Rear I/O Module
Table 2-1 9910DA-4Q-3G Rear I/O Modules continued
9910DA-4Q-3G Rear I/O Module Description RM20-9910-4Q-E Provides the following connections:
Four SDI/ASI video inputs (SDI IN A thru SDI IN D)
16 DA outputs (SDI OUT 1 thru SDI OUT 16)
9910DA-4Q-3G-OM (V1. 3) 9910DA- 4 Q-3G P RODU CT MA N UAL 2-9
Page 22
This page intentionally blank
2-10 9910DA-4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Page 23
Chapter 3

Chapter 3 Operating Instructions

Overview

This chapter contains the following information:
Accessing the 9910DA-4Q-3G Card via Remote Control (p. 3-1)
Checking 9910DA-4Q-3G Card Information and Status (p. 3-2)
Card-Edge Controls and Indicators (p. 3-2)
Troubleshooting (p. 3-6)

Accessing the 9910DA-4Q-3G Card via Remote Control

The 9910DA-4Q-3G card can be remote monitored via DashBoard or
®
Cobalt DashBoard or Cobalt
Remote Control Panel. Access the 9910DA-4Q-3G card using
®
Remote Control Panel as described below.

Accessing the 9910DA-4Q-3G Card Using DashBoard

1. On the computer connected to the frame LAN, open DashBoard™.
2. As shown below, in the left side Basic View Tree locate the Network
Controller Card associ ated wit h the fra me con taining t he 9910DA- 4Q-3G card to be accessed (in this example, MFC-8320-N SN: 00108053”).
3. As shown below, expand the tree to access the cards within the frame.
Click on the card to be accessed (in this example, Slot 6: 9910DA-4Q-3G-RCK).
9910DA -4Q- 3G- OM (V1. 3) 9910DA-4Q-3G PRODUCT MANUAL 3-1
Page 24
3 Checking 9910DA-4Q-3G Card Information and Status
.

Checking 9910DA-4Q-3G Card Information and Status

The operating status of the 9910DA-4Q-3G card can be checked using DashBoard. Figure 3-1 shows and describes the 9910DA-4Q-3G card information screen using DashBoard™.
The Tree View shows the cards seen by DashBoard. In this example, Network Controller Card is hosting a 9910DA-4Q-3G card in slot 6.
Card Status/Info Displa y
This displays shows the 9910DA-4Q-3G operating status.
The Product Info sub-tab shows product identification and version, as well as power/ temperature details and Cobalt mfg PN of the currently-installed rear module and compatibility of the rear module with this card (with green indicating a compatible rear module).
Figure 3-1 9910DA-4Q-3G Card Info/Status Utility

Card-Edge Controls and Indicators

If card edge control is to be used for card DA mode, refer to Card-Edge Switches and Monitoring (p. 2-1) in Installation and Setup, Chapter 2.
3-2 9910DA - 4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Page 25
Operating Instructions 9910DA-4Q-3G Function Menu List and Descriptions

9910DA-4Q-3G Function Menu List and Descriptions

Table 3-1 individually lists and describes each 9910-DA-4Q-3G function menu and its related list selections, controls, a nd paramete rs. Where helpful, examples showing usage of a function are also provided. Table 3-1 is primarily based upon using DashBoard to access each function and its corresponding menus and parameters.
Table 3-1 9910-DA-4Q-3G Function Menu List
Provides card input-to-output crosspoint routing matrix

Output Source Crosspoint Control

controls and input failover selection.
Output Source Select Selects the input routing for each of the four 4x DA output quadrants. Shown below are common muxing schemes, but any of the four 4x DA output quadrants can be sourced from any of the four card inputs.
Settings shown here provides quad 4x4 DA function.
Quad 4:4
A
B
C
D
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16
Settings shown here provides dual 2x8 DA function.
Dual 2:8
A
B
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
9910DA-4Q-3G-OM (V1. 3) 9910DA- 4 Q-3G P RODU CT MA N UAL 3-3
Page 26
3 9910DA-4Q-3G Function Menu List and Descriptions
Table 3-1 9910-DA-4Q-3G Function Menu List continued
(continued)
Output Source Select (cont.)
Settings shown here provides single 1x16 DA function.
Single 1:16
A
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
Failover Select and Status Selects an alternate failover input source for each of the four DA quadrants. If failover is not desired for a particular quadrant, the quadrant can be set to Off (as shown in this example for the 5-8 quadrant).
Shown in this example, the card is set as a single 1:16 DA using primary source In A with failover to In B selected as the failover for all outputs.
If a failover is in effect, the failover sourcing is shown on the card Status page (as shown in this example of all outputs now being sourced from Input B instead of Input A and a Last Event of Lost Input A”.
3-4 9910DA - 4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Page 27
Operating Instructions 9910DA-4Q-3G Function Menu List and Descriptions
Table 3-1 9910-DA-4Q-3G Function Menu List continued
(9910DA-4Q-3G-RCK only) Provides reclock enable/

Reclock Outputs Control

disable for each of the four DA quadrants.
Reclock Enable/Disable

Presets

Preset Save/Load Controls
Sets reclocking as enabled or disabled for each of the four DA quadrants. In the example here with the card being used as a quad 1x4 DA with an
ASI input feeding quadrant 13-16 with other inputs as SDI, Disabled setting for 13-16 accommodates ASI on this path while providing reclocking for the other paths that are passing SDI.
Note: Reclocking Enabled provides automatic reclocking that sets
reclocking automatically for SMPTE 259M, 292M, and 424M SDI signals. Disable setting forces disable regardless of signal detected.
If passing signals such as ASI or MADI, it is recommended to set the path carrying these signal type to Disabled.
Allows user control settings to be saved in a Preset and then recalled (loaded) as desired.
Card Settings > Save button allows all custom user setting configurations to be saved to a Preset.
Card Settings > Load button allows the saved preset to be loaded (recalled and applied).
In the example here:
- Preset 1 would be set up to save quad 1x4 routing selection with reclocking enabled for all output quadrants.
- Preset 2 would be set up to save quad 1x4 routing selection but in this preset, output quadrant 13-16 is saved with reclocking disabled.
9910DA-4Q-3G-OM (V1. 3) 9910DA- 4 Q-3G P RODU CT MA N UAL 3-5
Page 28
3 Troubleshooting

Troubleshooting

Basic Troubleshooting Checks

Failures of a general nature (affecting many cards and/or functions simultaneously), or gross inoperability errors are best addressed first by performing basic checks before proceeding further. Table 3-2 provides basic system checks that typically locate the source of most general problems. If required and applicable, perform further troubleshooting in accordance with the other troubleshooting tables in this section.
Table 3-2 Basic Troubleshooting Checks
Item Checks
Verify pow er presence and characteristics
Check Cable connection secureness and connecting points
Card seating within slots Make certain all cards are properly seated within its frame slot. (It is best to
Check status indicators and displays
On both the frame Network Controller Card and the 9910DA-4Q-3G, in all cases when power is being properly supplied there is always at least one indicator illuminated. Any card showing no illuminated indicators should be cause for concern.
Check the Power Consumed indication for the 9910DA-4Q-3G card. This can be observed using the DashBoard Card Info pane.
If display shows no power being consumed, either the frame power supply, connections, or the 9910DA-4Q-3G card itself is defective.
If display shows excessive power being consumed (see Technical Specifications (p. 1-6) in Chapter 1, “Introduction”), the 9910DA-4Q-3G card may be defective.
Make certain all cable connections are fully secure (including coaxial cable attachment to cable ferrules on BNC connectors). Also, make certain all connecting points are as intended. Make certain the selected connecting points correlate to the intended card inputs and/or outputs. Cabling mistakes are especially easy to make when working with large I/O modules.
assure proper seating by ejecting the card and reseating it again.) On both DashBoard and the 9910DA-4Q-3G card edge indicators, red
indications signify an error condition. If a status indicator signifies an error, proceed to the following tables in this section for further action.
Check card-edge switch settings
Troubleshoot by substitution
3-6 9910DA - 4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Refer to Chapter 2, Setup and Installation. Make certain switches are set for intended control mode (local or remote). If set for local, remote control is locked out.
All cards within the frame can be hot-swapped, replacing a suspect card or module with a known-good item.
Page 29
Operating Instructions Troubleshooting

Troubleshooting Network/Remote Control Errors

Refer to Cobalt® reference guide Remote Control User Guide (PN 9000RCS-RM) for network/remote control troubleshooting information.

In Case of Problems

Should any problem arise with this product that was not solved by the information in this section, please contact the Cobalt Digital Inc. Technical Support Department.
If required, a Return Material Authorizatio n num ber (RMA) will be issued to you, as well as specific shipping instructions. If required, a temporary replacement item will be made available at a nominal charge. Any shipping costs incur r ed are the customers responsibility. All products shipped to you from Cobalt Digital Inc. will be shipp ed collect.
The Cobalt Digital Inc. Technical Support Department will continue to provide advice on any product manufactured by Cobalt Digital Inc., beyond the warranty period without charge, for the life of the product.
See Contact Cobalt Digi tal Inc. (p. 1-8) in Chapter 1, “Introduction“ for contact information.
9910DA-4Q-3G-OM (V1. 3) 9910DA- 4 Q-3G P RODU CT MA N UAL 3-7
Page 30
This page intentionally blank
3-8 9910DA - 4Q-3G PRODUC T MAN U AL 9910DA-4Q-3G-OM (V1. 3)
Page 31
Page 32
Cobalt Digital Inc.
2506 Galen Drive Champaign, IL 61821 Voice 217.344.1243 Fax 217.344.1245 www.cobaltdigital.com
9910DA-4Q-3G-OM (V1.3) Printed in USA
Loading...