CMP T3CDSX User Manual

DUBAI • HOUSTON • NEWCASTLE • SINGAPORE • SHANGHAI • PUSAN • PERTH
TECHNICAL DATA
CABLE GLAND TYPE : T3CDSX INGRESS PROTECTION : IP66, NEMA 4X, DELUGE TO DTS01-01, Oil Resistan PROCESS CONTROL SYSTEM : BS EN ISO 9001
: ISO/IEC 80079-34:2011
INSTALLATION INSTRUCTIONS FOR INSTALLATION OF CMP CABLE
HAZARDOUS AREA CLASSIFICATION
ATEX CERTIFICATION No : SIRA 06ATEX1283X & SIRA 06ATEX4328X ATEX CERTIFICATION CODE : II 2 GD Ex d IIC / Ex e II / Ex nR II / Ex tD A21 IP66 IEC Ex CERTIFICATION No : IEC Ex SIR.07.0005X IEC Ex CERTIFICATION CODE : Ex d IIC / Ex e II / Ex nR II / Ex tD A21 IP66 CSA-US CERTIFICATION No : CSA.02.310517X CSA-US CERTIFICATION CODE : Class I, Div 2, Groups ABCD; Class II, Div 2, Groups EFG; Class III; Ex d IIC; Ex e II;
UL CERTIFICATION FILE : E200163 UL CERTIFICATION CODE : Class I, Zone 1, AEx II; TYPE 4X, OIL RES II
INSTALLATION INSTRUCTIONS
Installation should only be performed by a competent person using the correct tools. Read all instructions before beginning installation.
SPECIAL CONDITIONS FOR SAFE USE
1. The glands ranges shall only be used on enclosures where the temperature, at the point of mounting, is in the range -60°C to +130°C.
2. When used with braided cable, the cable glands shall be used for fixed installations only. Cables must be effectively clamped to prevent twisting and pulling.
3. When used in Group I applications, the equipment must only be mounted where the risk of mechanical impact is low.
4. According to CEC Wiring methods, connectors with Metric entry threads are only suitable for Areas classified in ZONES unless fitted with an approved Metric to NPT thread conversion adaptor.
ACCESSORIES
The following accessories are available from CMP Products, as optional extras, to assist with fixing, sealing and earthing :-
Locknut | Earth Tag | Serrated Washer | Entry Thread (I.P.) Sealing Washer | Shroud *
Cable Gland
20S/16 M20 1/2" 3/4" 15.0 3.2 8.7 6.1 13.4 0.15 0.5 24.0 25.9 70.0 20S16T3CDSX1RA 0.170
* For IP67 & IP68 requirements the Cable Diameter “B” (minimum value) shown above should be increased by 1.0 mm to ensure complete compliance
Available Entry Threads
ize
S
20S M20 1/2" 3/4" 15.0 6.1 11.7 9.5 15.9 0.15 0.5 24.0 25.9 70.0 20ST3CDSX1RA 0.170
20 M20 1/2" 3/4" 15.0 6.5 14.0 12.5 20.9 0.2 0.5 30.5 32.9 72.0 20T3CDSX1RA 0.256
25S M25 3/4" 1" 15.0 11.1 20.0 14.0 22.0 0.2 0.6 37.5 40.5 82.0 25ST3CDSX1RA 0.384
25 M25 3/4" 1" 15.0 11.1 20.0 18.2 26.2 0.2 0.6 37.5 40.5 82.0 25T3CDSX1RA 0.379
32 M32 1" 1 1/4" 15.0 17.0 26.3 23.7 33.9 0.2 0.6 46.0 49.7 85.0 32T3CDSX1RA 0.560
40 M40 1 1/4" 1 1/2" 15.0 23.5 32.2 27.9 40.4 0.2 0.8 55.0 59.4 86.0 40T3CDSX1RA 0.848
50S M50 1 1/2" 2" 15.0 31.0 38.2 35.2 46.7 0.2 0.8 60.0 64.8 98.0 50ST3CDSX1RA 1.055
50 M50 2" 2 1/2" 15.0 35.6 44.1 40.4 53.1 0.3 0.8 70.0 75.6 100.0 50T3CDSX1RA 1.521
63S M63 2" 2 1/2" 15.0 41.5 50.0 45.6 59.4 0.3 0.8 75.0 81.0 108.0 63ST3CDSX1RA 1.750
63 M63 2 1/2" 3" 15.0 47.2 56.0 54.6 65.9 0.3 0.8 80.0 86.4 103.0 63T3CDSX1RA 1.685
75S M75 2 1/2" 3" 15.0 54.0 62.0 59.0 72.1 0.3 0.8 89.0 96.1 105.0 75ST3CDSX1RA 2.345
75 M75 3" 3 1/2" 15.0 61.1 68.0 66.7 78.5 0.3 0.8 99.0 106.9 114.0 75T3CDSX1RA 3.200
90 M90 3" 3 1/2" 15.0 66.6 79.3 76.2 90.4 0.4 0.8 114.0 123.1 140.0 90T3CDSX1RA 5.100
100 M100 4" 4 1/2" 15.0 76.0 91.0 86.1 101.5 0.4 0.8 123.0 132.8 170.0 100T3CDSX1RA 6.500
115 M115 4 1/2" 5" 15.0 86.0 98.0 101.5 110.3 0.4 0.8 133.4 144.1 210.0 115T3CDSX1RA 7.000
130 M130 5" 6" 15.0 97.0 115.0 114.2 123.3 0.4 0.8 146.1 157.8 250.0 130T3CDSX1RA 7.800
I, The undersigned, hereby declare that the equipment referred to herein conforms to the requirements of the ATEX Directive 94/9/EC and the following
Standard Option
etricNPT
standards:-
PT
N
Class I, Zone 1, AEx d IIC; Class I, Zone 1, AEx e II
Minimum
hread
T Length
Cable
Bedding
Diameter
MinMaxMinM
Dimensions are displayed in millimetres unless otherwise stated
Overall Cable
Diameter
ax
Braid Wire
Diameter
in
ax
Across
Flats
ax
Across
Corners
ax
Protrusion
Length
Ordering Reference
(Brass Metric)
Cable Gland
Weight
(Kgs)
GLAND TYPES T3CDSX
CABLE GLAND FOR USE WITH WIRE BRAID, STRIP, AND TAPE ARMOUR FOR USE IN HAZARDOUS LOCATIONS.
INCORPORATING EC DECLARATION OF CONFORMITY TO DIRECTIVE 94/9/EC
CMP TRITON
T
CDS
COMPENSATING DISPLACEMENT SEAL SYSTEM.
Cable Gland Selection Table
LISTED MARINE SHIPBOARD CABLE FITTING 31YM
T
DELUGE PROOF CABLE GLAND FEATURING
CABLE GLAND
CABLE GLAND
TYPE T3CDSX
TYPE T3CDSX
CMP Document No. FI409 Issue 4 01/13
EN60079-0:2006, EN60079-1:2007, EN60079-7:2007, EN60079-15:2005, BS 6121:1989, EN50262:19989 (Amd 2001), EN61241-0:2004, EN61241-1:2004
Dr Geof Mood - Technical Director - (Authorised Person)
Glasshouse Street • St. Peters • Newcastle upon Tyne • NE6 1BS
Tel: +44 191 265 7411 • Fax: +44 191 265 0581
0518
Notified Body: Sira Certification Service, Rake Lane, Chester CH4 9JN, England.
E-Mail: cmp@cmp-products.co.uk • Web: www.cmp-products.com
www.cmp-products.com
Logo’s shown for illustration purposes only. Please check certification for details
DUBAI • HOUSTON • NEWCASTLE • SINGAPORE • SHANGHAI • PUSAN • PERTH
www.cmp-products.com
INSTALLATION INSTRUCTIONS FOR CMP CABLE GLAND T3CDSX
CABLE GLAND COMPONENTS
1. Entry Item
2. Body
3. Compensating Sleeve
4. Armour Cone
5. AnyWay Clamping Ring
6. Outer Seal Nut
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING THE INSTALLATION
SUB-ASSEMBLY A
ITEM 4
ITEM 5 SUB-ASSEMBLY B
4321 65
4. Pass the cable through sub-assembly A, spacing the braid evenly around the cone. Whilst continuing to push the cable forward to keep the cable braid in contact with the cone, tighten the compensating sleeve (3) into the entry component (1) until all the threads are used. (Note that the internal compensator will prevent the cable gland inner seal from being over-tightened onto the cable inner sheath.)
5. Terminate the cable by tightening the body (2) onto the entry component (1) using a spanner on each part. Tighten the body until the body and entry components are metal to metal and cannot be tightened further.
“CDS” INNER SEAL
HOUSING
DELUGE
SEAL
BRAID CONE
ANYWAY
CLAMPING RING
BODY AND OUTER
SEAL NUT
1. Separate the gland into two sub-assemblies, A and B, by unscrewing the body (2) from the entry item (1). Note that items (4) and (5) are loose items.
2. Prepare the cable by stripping back the cable outer sheath and armour to suit the equipment geometry. Expose the braid by stripping back the outer sheath further using the table below as a guide.
Cable Strip Length “L”
CABLE GLAND SIZE 20S/16, 20S, 20 25S, 25, 32, 40 50S, 50, 63S, 63 75S, 75, 90, 100, 115, 130
CABLE STRIP LENGTH “L” 12mm 15mm 18mm 20mm
3. Secure the entry components (sub-assembly A) into the equipment. (Not for remote installation) Pass the sub-assembly B and AnyWay clamping ring (5) over the cable, outer seal first. Insert the armour cone (4) in the sub-assembly B:
6. Tighten the outer seal nut (6) until it comes to an effective stop. This will occur when:­A) The outer seal nut (6) has clearly engaged the cable and cannot be further tightened without the use of excessive force by the installer. B) The outer seal nut (6) is metal to metal with the body of the gland (2).
www.cmp-products.com
DUBAI • HOUSTON • NEWCASTLE • SINGAPORE • SHANGHAI • PUSAN • PERTH
Loading...