TECHNICAL DATA
CABLE GLAND TYPE : PXSS2K-REX INGRESS PROTECTION : IP66, IP67, IP68, Type 4X; Oil Resistant II PROCESS CONTROL SYSTEM : BS EN ISO 9001
: ISO/IEC 80079-34:2011
HAZARDOUS AREA CLASSIFICATION
ATEX CERTIFICATION No : SIRA 06ATEX1097X & SIRA 07ATEX4326X ATEX CERTIFICATION CODE : II 2 GD Ex d IIC / Ex e II / Ex nR II / Ex tD A21 IP66 IEC Ex CERTIFICATION No : IEC Ex SIR.06.0044X IEC Ex CERTIFICATION CODE : Ex d IIC / Ex e IIC / Ex nR II / Ex tD A21 IP66 CSA-US CERTIFICATION No. : 2288626 CSA-US CERTIFICATION CODE : Class I Div 1, 2, Groups A, B, C, D: Class II, Div 1, 2, Groups F and G; Class III, Div 1, 2;
Class I Zone 1 AEx d IIC / AEx e II (Code details depends upon application - please see certificate)
INSTALLATION INSTRUCTIONS
Installation should only be performed by a competent person using the correct tools. Spanners should be used for tightening. Read all instructions before beginning installation.
SPECIAL CONDITIONS FOR SAFE USE
1. The cable gland ranges shall only be used where the temperature, at the point of entry, is in the following ranges:
-60°C to +85°C.
2. The cable glands used for terminating braid cable are only suitable for fixed installations. Cables must be effectively clamped to prevent twisting and pulling.
3. The entry component threads may need additional sealing to maintain the ingress protection ratings as applicable to the associated equipment to which it is attached.
4. According to the CEC wiring code, connectors with metric threads are only suitable for Areas Classified in ZONES unless fitted with an approved Metric to NPT thread conversion adaptor.
5. Wiring method for type of cables that can be used in Class I, Div. 1, 2, and Class I, Zone 1, 2, Classified Areas according to 60079-14 installation wiring method restrictions.
6. Shipboard Cables are for use on Marine Platform or shipboards only and are subject to local authorities having jurisdiction on the installation.
INSTALLATION INSTRUCTIONS FOR CMP CABLE GLAND TYPE PXSS2K-REX
FOR TERMINATION OF UNARMOURED, BRAIDED CABLES AND EXTRA HARD CORD USEAGE CABLES. FOR USE IN HAZARDOUS LOCATIONS.
INCORPORATING EC DECLARATION OF CONFORMITY TO DIRECTIVE 94/9/EC
CABLE GLAND
CABLE GLAND
TYPE
TYPE
PXSS2K-REX
PXSS2K-REX
ACCESSORIES
The following accessories are available from CMP Products, as optional extras, to assist with fixing, sealing and earthing :-
Locknut | Earth Tag | Serrated Washer | Entry Thread (I.P.) Sealing Washer | Shroud *
Available Entry Threads
Cable Gland
Size
20S/16 M20 1/2” 3/4” 15.0 34 12.6 3.1 8.7 30.5 32.9 58.5 20S16PXSS2KREX1RA PVC04 0.200
20S M20 1/2” 3/4” 15.0 34 12.6 6.1 11.7 30.5 32.9 58.5 20SPXSS2KREX1RA PVC04 0.200
20 M20 1/2” 3/4” 15.0 34 12.6 6.5 14.0 30.5 32.9 60.5 20PXSS2KREX1RA PVC05 0.250
25 M25 3/4” 1” 15.0 80 17.5 11.1 20.0 37.5 40.5 67.5 25PXSS2KREX1RA PVC09 0.403
32 M32 1” 1-1/4” 15.0 115 23.6 17.0 26.3 46.0 49.7 69.5 32PXSS2KREX1RA PVC10 0.555
40 M40 1-1/4” 1-1/2” 15.0 185 30.0 22.0 32.1 55.0 59.4 78.0 40PXSS2KREX1RA PVC13 0.600
50S M50 1-1/2” 2” 15.0 274 36.6 29.5 38.2 60.0 64.8 75.5 50SPXSS2KREX1RA PVC15 0.605
50 M50 2” 2-1/2” 15.0 343 41.0 35.6 44.1 70.0 75.6 80.5 50PXSS2KREX1RA PVC18 0.620
63S M63 2” 2-1/2” 15.0 466 47.9 40.1 50.1 75.0 81.0 91.5 63SPXSS2KREX1RA PVC21 0.705
63 M63 2-1/2” 3” 15.0 585 53.7 47.2 56.0 80.0 86.4 92.0 63PXSS2KREX1RA PVC23 0.730
75S M75 2-1/2” 3” 15.0 727 59.9 52.8 62.0 89.0 94.3 99.0 75SPXSS2KREX1RA PVC24 1.150
75 M75 3” 3-1/2” 15.0 837 64.3 59.1 68.0 99.0 106.9 102.0 75PXSS2KREX1RA PVC26 1.150
90 M90 3” 3-1/2”” 15.0 1146 75.3 66.6 79.4 114.0 123.1 120.0 90PXSS2KREX1RA PVC31 2.700
100 M100 4” - 15.0 1480 85.6 80.0 90.9 133.0 143.6 135.0 100PXSS2KREX1RA LSF33 3.400
I, the undersigned, hereby declare that the equipment referred to herein conforms to the requirements of the ATEX Directive 94/9/EC and the following
standards:-
Standard Option
Metric NPT NPT Max Min Max Max Max
Minimum
Thread Length
Number
Cores
All dimensions in millimetres unless otherwise stated
Of
Diameter
Over
Conductors
Overall Cable
Diameter
Across
Flats
Across
Corners
Protrusion
Length
Ordering
Reference
(Brass Metric)**
PVC
Shroud
Reference
*
Cable Gland
Weight
(KGs)
Cable Gland Selection Table
CMP Document No. FI403 Issue 4 01/13
EN60079-0:2006, EN60079-1:2007, EN60079-7:2007, EN60079-15:2005, BS 6121:1989, EN50262:1998 (Amd 2001), EN61241-0:2007, EN61241-1:2004
Dr Geof Mood - Technical Director - (Authorised Person)
Glasshouse Street • St. Peters • Newcastle upon Tyne • NE6 1BS
0518
Notified Body: Sira Certification Service, Rake Lane, Chester CH4 9JN, England.
E-Mail: cmp@cmp-products.com • Web: www.cmp-products.com
www.cmp-products.com
Logo’s shown for illustration purposes only. Please check certification for details
DUBAI • HOUSTON • NEWCASTLE • SINGAPORE • SHANGHAI • PUSAN • PERTH
www.cmp-products.com
INSTALLATION INSTRUCTIONS FOR CMP CABLE GLAND TYPE PXSS2K-REX
CABLE GLAND COMPONENTS
1. Resin
2. Entry Component “A”
3. Compound Tube
4. Resin Dam
5. Spacer
6. Main Item
7. Skid Washer
8. Outer Seal
9. Outer Seal Nut
10. Thread Shield
10
1 5
Resin Dam
63 42
‘L’
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING THE INSTALLATION
1. Separate the gland components by removing the main item (6) and outer seal nut assembly (7, 8, 9). Slacken the outer seal nut slightly to relax the seal and pass the main item/outer seal nut assembly over the cable, nut end first. Prepare the cable by stripping back the outer sheath to suit the equipment.
87 9
4. Refer to ‘RapidEx Resin’ assembly instructions to fill the connector Compound Tube
with the required amount of resin. The resin should not be mixed or applied at temperatures below 5°C (40°F).
Resin Dam with good contact with cable sheath or electrical tape.
Ensure Resin Dam is in position in the gland and making a good seal against the inner sheath.
Resin Dam with poor contact with cable cores.
Do not disassemble the gland to inspect the Resin Dam, diagrams are for representation.
2. Remove any bedding or fillers from around the cable cores. If the cable cores have screens, these should be unravelled and then twisted together to form a single core. This single core and/or any drain wires present should be sleeved with some heat shrink tubing.
Electrical tape MUST be wrapped around the tips of the cable cores. This is to ensure the cable cores are together and also to cover any sharp edges that could potentially tear the Resin Dam during installation.
3. Feed the cable carefully into the entry item (2) through the resin dam (4). Reassemble the gland and adjust the position of the cable if necessary to that the outer sheath just protrudes through the resin dam. (Use length ‘L’ as a guide for positioning the cable). Tighten the outer seal nut enough to secure the gland.
5. Once the resin has cured remove the thread shield, loosen the outer seal nut and remove the main item (6) and outer seal nut assembly (7,8,9) from the entry item (2). Fit the entry item into the equipment.
6. Re-install the cable assembly into the entry item and fully tighten the main item (6) onto the entry item (2). Tighten the outer seal nut (9) until it comes to an effective stop. This will occur when :-
A) The outer seal nut (9) has clearly engaged the cable and cannot be further tightened without the use of excessive force by the installer. B) The outer seal nut (9) is metal to metal with the main item (6).
N.B. If the outer sheath is too large to pass through the spacer then wrap some electrical tape around the cores at the point they pass through the resin dam.
www.cmp-products.com
DUBAI • HOUSTON • NEWCASTLE • SINGAPORE • SHANGHAI • PUSAN • PERTH
Loading...