TECHNICAL DATA
CABLE GLAND TYPE : PX2K-REX, PX2KW-REX & PX2KX-REX
INGRESS PROTECTION : IP66, IP67, IP68, Type 4X; Oil Resistant II
PROCESS CONTROL SYSTEM : BS EN ISO 9001
HAZARDOUS AREA CLASSIFICATION
ATEX CERTIFICATION No : SIRA 06ATEX1097X & SIRA 07ATEX4326X
ATEX CERTIFICATION CODE : II 2 GD Ex d IIC / Ex e II / Ex nR II / Ex tD A21 IP66
IEC Ex CERTIFICATION No : IEC Ex SIR.06.0044X
IEC Ex CERTIFICATION CODE : Ex d IIC / Ex e IIC / Ex nR II / Ex tD A21 IP66
CSA-US CERTIFICATION No. : 2288626
CSA-US CERTIFICATION CODE : Class I Div 1, 2, Groups A, B, C, D: Class II, Div 1, 2, Groups F and G; Class III, Div 1, 2;
INSTALLATION INSTRUCTIONS
Installation should only be performed by a competent person using the correct tools. Spanners should be used for tightening. Read all instructions
before beginning installation.
SPECIAL CONDITIONS FOR SAFE USE
1. The cable gland ranges shall only be used where the temperature, at the point of entry, is in the following ranges:
-60°C to +85°C.
2. The cable glands used for terminating braid cable are only suitable for fixed installations. Cables must be effectively clamped to prevent twisting
and pulling.
3. The entry component threads may need additional sealing to maintain the ingress protection ratings as applicable to the associated equipment to
which it is attached.
4. According to the CEC wiring code, connectors with metric threads are only suitable for Areas Classified in ZONES unless fitted with an approved
Metric to NPT thread conversion adaptor.
5. Wiring method for type of cables that can be used in Class I, Div. 1, 2, and Class I, Zone 1, 2, Classified Areas according to 60079-14 installation
wiring method restrictions.
6. Shipboard Cables are for use on Marine Platform or shipboards only and are subject to local authorities having jurisdiction on the installation.
ACCESSORIES
The following accessories are available from CMP Products, as optional extras, to assist with fixing, sealing and earthing :-
Locknut | Earth Tag | Serrated Washer | Entry Thread (I.P.) Sealing Washer | Shroud *
Available Entry
Threads
Cable
Gland
Size
20S/16 M20 1/2” 3/4” 15.0 11 12.6 14.9 6.1 11.5 0.15 0.5 0.8 1.0 30.5 33.6 20S16PX2KREX1RA
20S M20 1/2” 3/4” 15.0 11 12.6 14.9 9.5 15.9 0.15 0.5 0.8 1.25 30.5 33.6 20SPX2KREX1RA
25S M25 3/4” 1” 15.0 38 17.5 21.0 14.0 22.0 0.2 0.6 1.25 1.6 37.5 41.3 25SPX2KREX1RA
50S M50 1-1/2” 2” 15.0 115 36.6 45.7 35.2 46.7 0.2 0.8 2.0 2.5 60.0 66.0 50SPX2KREX1RA
63S M63 2” 2-1/2” 15.0 140 47.9 58.4 45.5 59.4 0.3 0.8 2.0 2.5 75.0 82.5 63SPX2KREX1RA
75S M75 2-1/2” 3” 15.0 140 59.9 72.8 58.0 72.1 0.3 0.8 2.0 2.5 89.0 97.9 75SPX2KREX1RA
100 M100 4” - 15.0 200 85.6 100.5 86.1 101.5 0.4 0.8 3.15 4.0 133.0 146.3 100PX2KREX1RA
Note: Codes shown are for PX2K-REX glands, for PX2KW-REX or PX2KX-REX add “W” or “X” respectively, e.g. 20PX2KWREX1RA, 20PX2KXREX1RA
I, the undersigned, hereby declare that the equipment referred to herein conforms to the requirements of the ATEX Directive 94/9/EC and the following
Standard Option Grooved Cone Stepped Cone
Metric NPT NPT Max Max Min Max Min Max Min Max Max Max
20 M20 1/2” 3/4” 15.0 21 12.6 19.9 12.5 20.9 0.2 0.5 0.8 1.25 30.5 33.6 20PX2KREX1RA
25 M25 3/4” 1” 15.0 38 17.5 25.2 18.2 26.2 0.2 0.6 1.25 1.6 27.5 41.3 25PX2KREX1RA
32 M32 1” 1-1/4” 15.0 59 23.6 32.9 23.7 37.9 0.2 0.6 1.6 2.0 55.0 50.6 32PX2KREX1RA
40 M40 1-1/4” 1-1/2” 15.0 89 30.0 39.4 27.9 40.4 0.2 0.8 1.6 2.0 55.0 60.5 40PX2KREX1RA
50 M50 2” 2-1/2” 15.0 115 41.0 52.1 40.4 53.1 0.3 0.8 2.0 2.5 70.0 77.0 50PX2KREX1RA
63 M63 2-1/2” 3” 15.0 140 53.7 64.9 54.6 65.9 0.3 0.8 2.0 2.5 80.0 88.0 63PX2KREX1RA
75 M75 3” 3-1/2” 15.0 140 64.3 77.5 66.7 78.5 0.3 0.8 2.5 3.0 99.0 108.9 75PX2KREX1RA
90 M90 3-1/2” 3-1/2”” 15.0 140 75.3 89.4 78.2 90.4 0.4 0.8 3.0 3.5 114.0 125.4 90PX2KREX1RA
standards:-
Minimu
m
Thread
Length
: ISO / IEC 80079-34:2011
Class I Zone 1 AEx d IIC / AEx e II
(Code details depends upon application - please see certificate)
Diameter
Number
Of
Cores
Over
Conductors
All dimensions in millimetres unless otherwise stated
Maximum
Diameter
Over Lead
Sheath
Overall Cable
Diameter
Armour Wire Diameter
Across
Flats
Across
Corners
Ordering
Reference
(Brass Metric)
**
INSTALLATION INSTRUCTIONS FOR
CMP CABLE GLAND TYPES PX2K-REX,
PX2KW-REX, & PX2KX-REX
FOR TERMINATION OF CABLES WITH WIRE BRAID, TAPE ARMOUR (STA/DSTA), STRIP ARMOUR &
SINGLE WIRE ARMOUR (SWA) (WITH LEAD INNER SHEATH ON PB VARIANTS) . FOR USE IN
HAZARDOUS LOCATIONS.
INCORPORATING EC DECLARATION OF CONFORMITY TO DIRECTIVE 94/9/EC
CABLE GLAND TYPES
CABLE GLAND TYPES
PX2K-REX, PX2KW-REX &
PX2K-REX, PX2KW-REX &
PX2KX-REX & VARIANTS
PX2KX-REX & VARIANTS
Cable Gland Selection Table
CMP Document No. FI402 Issue 5 0113
EN60079-0:2006, EN60079-1:2007, EN60079-7:2007, EN60079-15:2005, BS 6121:1989, EN50262:1998 (Amd 2001), EN61241-0:2004, EN61241-1:2004
Dr Geof Mood - Technical Director - (Authorised Person)
Glasshouse Street • St. Peters • Newcastle upon Tyne • NE6 1BS
Tel: +44 191 265 7411 • Fax: +44 191 265 0581
0518
Notified Body: Sira Certification Service, Rake Lane, Chester CH4 9JN, England.
E-Mail: cmp@cmp-products.com • Web: www.cmp-products.com
www.cmp-products.com
Logo’s shown for illustration purposes only. Please check certification for details
DUBAI • HOUSTON • NEWCASTLE • SINGAPORE • SHANGHAI • PUSAN • PERTH
INSTALLATION INSTRUCTIONS FOR CMP CABLE GLAND TYPES PX2K-REX, PX2KW-REX,
& PX2KX-REX
CABLE GLAND COMPONENTS
1. Resin
2. Entry Component
3. Compound Tube
4. “O” Ring
5a. Grooved Armour Cone (XYZ)
5b. Stepped Armour Cone (W)
6. Body
7. AnyWay Clamping Ring
8. Outer Seal Nut Assembly
9. Thread Shield
9
Resin
Dam
5a342
b
5
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING THE INSTALLATION
67 8
www.cmp-products.com
5. Insert the armour cone (5a or 5b) into the entry item (2) and pass the
cable through them and the resin dam until the braid or armour contacts
the cone and make sure it is evenly spaced around it. Tighten the body
(6) to lock the braid or armour. Do not tighten the outer seal nut at this
stage. (On PB variants the earthing device automatically makes contact
with the lead sheath).
Fit the thread shield over the entry threads to protect them prior to
installing the resin.
1. The PX2K-REX type cable gland is supplied as a Universal Kit with two armour cones, the grooved
armour cone (5a) is suitable for Strip Armour, Tape Armour and Braided Cables, and the stepped cone
(5b) is suitable for Wire Armour (SWA) cables. The PX2KX-REX gland only has one cone (5a) and the
PX2KW-REX only has one cone (5b). (PB Variants have an earthing device for the lead sheath).
2. Separate the gland components by removing the body and outer seal nut assembly. Pass the body
and outer seal nut assembly (6),(8), and the AnyWay clamping ring (7) over the cable, outer seal nut
first.
3. Prepare the cable by stripping back the outer sheath and braid / armour to suit the equipment.
Expose the braid or armour further so that it can be formed around the armour cone by cutting back
the outer sheath by a length “L”. This length varies slightly depending upon cable diameter, but typical
values are shown below. The inner sheath should be long enough to just pass through the resin dam
when installed. (Typical length of inner sheath is shown as ‘M’ below.) On lead sheathed cables, the
lead sheath should be long enough to just pass through the armour cone when installed.
M
L
CABLE
GLAND SIZE
CABLE STRIP
LENGTH “L”
20S/16, 20S, 20 25S, 25, 32, 40 50S, 50, 63S, 63 75S, 75, 90
12 mm
(0.472 inches)
15 mm
(0.591 inches)
18 mm
(0.709 inches)
20 mm
(0.787inches)
6. Refer to ‘RapidEx Resin’ assembly instructions to fill the connector Compound Tube
with the required amount of resin (1). The resin should not be mixed or applied at
temperatures below 5°C (40°F).
Resin Dam
with good
contact against
inner sheath.
Ensure Resin Dam is
in position in the
gland and making a
good seal against the
inner sheath.
Resin Dam
with poor
contact with
cable cores.
Do not disassemble the gland to inspect the Resin Dam, diagrams
are for representation.
“M” 35 40 42 50
4. Remove any bedding or fillers from around the cable cores. If the cable cores have screens, these
should be unravelled and then twisted together to form a single core.
This single core and/or any drain wires present should be sleeved with some heat shrink tubing.
Electrical tape MUST be wrapped around the tips of the
cable cores. This is to ensure the cable cores are
together and also to cover any sharp edges that could
potentially tear the Resin Dam during installation.
www.cmp-products.com
7. Once the resin has cured remove the thread shield, loosen the body and remove the assembly
from the entry item. Fit the entry item into the equipment.
8. Re-install the assembly into the entry item and fully tighten the body (6) onto the entry item (2).
Tighten the outer seal nut assembly (8) until it comes to an effective stop. This will occur when :-
A) The outer seal nut has clearly engaged the cable and cannot be further tightened
without the use of excessive force by the installer.
B) The outer seal nut is metal to metal with the body of the gland (6).
DUBAI • HOUSTON • NEWCASTLE • SINGAPORE • SHANGHAI • PUSAN • PERTH