(Typical value measured at CMO’s module: V216B1-L01)
Color Chromaticity R=(0.644, 0.331)
G=(0.273,0.588)
B=(0.151,0.061)
W=(0.285,0.293)
*Please refer to “color chromaticity” on p.15
(Typical value measured at CMO’s module: V216B1-L01)
Cell Transparency [и]
Polarizer (CF side) Anti-glare coating,
Polarizer (TFT side) 484.4(H) x 275.8(w)
7.38%Typ.s
(Typical value measured at CMO’s module: V216B1-L01)
484.4(H) x 275.8(w). Hardness: 3H
1.3 MECHANICAL SPECIFICATIONS
Item Min. Typ. Max. Unit Note
Weight 606 g
I/F connector mounting
position
The mounting inclination of the connector makes
the screen center within ±0.5mm as the horizontal.
(2)
Note (1) Please refer to the attached drawings for more information of front and back outline dimensions.
(2) Connector mounting position
+/- 0.5mm
4
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 2.0
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: Aug. 15, 2008
Model No.: V216B1 – P01
Approval
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT (BASED ON CMO MODULE V216B1-L01)
Item Symbol
Storage Temperature TST -20 +60 ºC (1), (3)
Operating Ambient Temperature TOP 0 +50 ºC (1), (2), (3)
Altitude Operating A OP 0 5000 M (3)
Altitude Storage A ST 0 12000 M (3)
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation..
Љ 40 ºC).
Relative Humidity (%RH)
100
90
80
Min. Max.
Value
Unit Note
Note (2) The maximum operating temperature is based on the test condition that the surface temperature of
display area is less than or equal to 65 ºC with LCD module alone in a temperature controlled
chamber. Thermal management should be considered in your product design to prevent the surface
temperature of display area from being over 65 ºC. The range of operating temperature may
60
40
20
10
Operating Range
Storage Range
Temperature (ºC)
8060-20 400 20-40
degrade in case of improper thermal management in your product design.
Note (3) The rating of environment is base on LCD module. Leave LCD cell alone, this environment condition can’t
be guaranteed. Except LCD cell, the customer has to consider the ability of other parts of LCD module
and LCD module process.
5
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 2.0
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: Aug. 15, 2008
Model No.: V216B1 – P01
2.2 ABSOLUTE RATINGS OF ENVIRONMENT (OPEN CELL)
Storage Condition : With shipping package.
Storage temperature range : 25±5
Storage humidity range : 50±10%RH
Shelf life : a month
к
2.3 ELECTRICAL ABSOLUTE RATINGS
2.3.1 ELECTRICAL ABSOLUTE RATINGS (OPEN CELL)
Item Symbol
Power Supply Voltage Vcc -0.3 6.0 V
Input Signal Voltage VIN -0.3 3.6 V
Min. Max.
Value
Unit Note
3. ELECTRICAL CHARACTERISTICS
3.1 TFT LCD OPEN CELL
Parameter Symbol
Power Supply Voltage VCC 4.5 5.0 5.5 V (1)
Power Supply Ripple Voltage VRP - - 150 mV
Rush Current I
White - 0.50 - A
Power Supply Current
Differential Input High
LVDS
Interface
interface
Note (1) The module should be always operated within above ranges.
Threshold Voltage
Differential Input Low
Threshold Voltage
Common Input Voltage V
Terminating Resistor R
Input High Threshold Voltage VIH 2.7 - 3.3 V CMOS
Input Low Threshold Voltage V
Black - 0.85 0.95 A
Vertical Stripe
Ta = 25 ± 2 ºC
Value
Min. Typ. Max.
- - 3.0 A (2)
RUSH
ICC
- 0.75 - A
+100 - - mV
V
LVT H
- - -100 mV
V
LVTL
1.125 1.25 1.375 V
LVC
- 100 - ohm
T
0 - 0.7 V
IL
Unit Note
Approval
(3)
Note (2) Measurement Conditions:
6
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 2.0
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: Aug. 15, 2008
Model No.: V216B1 – P01
Approval
Vcc rising time is 470us
+5V
0.9Vcc
0.1Vcc
GND
470us
Note (3) The specified power supply current is under the conditions at Vcc = 5 V, Ta = 25 ± 2 ºC, fv = 60 Hz,
whereas a power dissipation check pattern below is displayed.
a. White Pattern
b. Black Pattern
Active Area
Active Area
7
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 2.0
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: Aug. 15, 2008
Model No.: V216B1 – P01
Approval
c. Vertical Stripe Pattern
Active Area
R
G
R
B
G
R
B
G
RR
G
B
B
B
B
R
R
R
G
G
G
G
B
B
B
B
R
R
4. BLOCK DIAGRAM
4.1 TFT LCD OPEN CELL
RX0(+/-)
RX1(+/-)
RX2(+/-)
RX3(+/-)
RXCLK(+/-)
SELLVDS
(P-TWO,196108-30041)
INPUT CONNECTOR
Vcc
GND
V/L
Inverter (W/O)
TIMING
CONTROLLER
DC/DC CONVERTER &
REFERENCE VOLTAGE
SCAN DRIVER IC
TFT LCD PANEL
(1366x3x768)
DATA DRIVER IC
BACKLIGHT UNIT
8
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!