1. GENERAL DESCRIPTION
1.1 OVERVIEW
N154Z6 - L03 is a 15.4” TFT Liquid Crystal Display module with single LED Backlight unit and 30 pins
LVDS interface. This module supports 1680 x 1050 Wide-SXGA+ mode and can display 262,144 colors.
The optimum viewing angle is at 6 o’clock direction.
1.2 FEATURES
- Thin and High Brightness
- WSXGA+ (1680 x 1050 pixels) resolution
- DE only mode
- 3.3V LVDS (Low Voltage Differential Signaling) interface with 2 pixel/clock
- Meet RoHS requirement
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
1.3 APPLICATION
- TFT LCD Notebook
1.4 GENERAL SPECIFICATI0NS
Item Specification Unit Note
Active Area 331.128 (H) x 206.955 (V) (15.4 inch Diagonal) mm
Bezel Opening Area 335 (H) x 211.1 (V) mm
Driver Element a-si TFT active matrix - Pixel Number 1680 x 3 (RGB) x 1050 pixel Pixel Pitch 0.1971 x 0.1971 mm Pixel Arrangement RGB vertical stripe - Display Colors 262,144 color Transmissive Mode Normally white - Surface Treatment Hard coating (3H), Anti-glare - -
1.5 MECHANICAL SPECIFICATIONS
Item Min. Typ. Max. Unit Note
Horizontal (H) 343.5 344344.5 mm
Module Size
Note (1) Please refer to the attached drawings for more information of front and back outline dimensions.
Vertical (V) 221.5 222222.5 mm
Depth (D) ---6.06.3 mm
Weight --- 515 530 g -
(1)
(1)
4 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 5
Global LCD Panel Exchange Center
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item Symbol
Storage Temperature TST -20 +60 ºC (1)
Operating Ambient Temperature TOP 0 +50 ºC (1), (2)
Shock (Non-Operating) S
Vibration (Non-Operating) V
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta Љ 40 ºC).
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Note (2) The temperature of panel surface should be 0 ºC Min. and 50 ºC Max.
www.panelook.com
Min. Max.
- 220/2 G/ms (3), (5)
NOP
- 1.5 G (4), (5)
NOP
Value
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
Unit Note
Relative Humidity (%RH)
100
90
80
60
Operating Range
40
20
10
Storage Range
Temperature (ºC)
Note (3) 1 time for ± X, ± Y, ± Z. for Condition (220G / 2ms) is half Sine Wave,
8060-20400 20-40
Note (4) 10 ~ 500 Hz, 0.5 Hr / Cycle, 1 cycles for each X, Y, Z.
Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
so that the module would not be twisted or bent by the fixture.
The fixing condition is shown as below:
LCD Module
Side Mount Fixing Screw
gap=2mm
Bracket
Side Mount Fixing Screw
Stage
5 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 6
Global LCD Panel Exchange Center
2.2 ELECTRICAL ABSOLUTE RATINGS
2.2.1 TFT LCD MODULE
Item Symbol
Power Supply Voltage VCC -0.3 +4.0 V
Logic Input Voltage VIN -0.3 VCC+0.3 V
2.2.2 BACKLIGHT UNIT
Item
LED Light Bar Power Supply Voltage -5 * 8 3.4 * 8 V
LED Light Bar Power Supply Current -- 30 * 6 mA
Note (1) Permanent damage to the device may occur if maximum values are exceeded. Function operation
should be restricted to the conditions described under Normal Operating Conditions.
www.panelook.com
Value
Min. Max.
Value
Min Max.
Unit Note
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
(1)
Unit Note
DC
DC
(1), (2)
Note (2) Specified values are for LED (Refer to Section 3.2 for further information).
6 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 7
Global LCD Panel Exchange Center
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
3. ELECTRICAL CHARACTERISTICS
3.1 TFT LCD MODULE Ta = 25 ± 2 ºC
Parameter Symbol
Min. Typ. Max.
Power Supply Voltage Vcc 3.0 3.3 3.6 V Ripple Voltage VRP 50 mV Rush Current I
1.5 A (2)
RUSH
Initial Stage Current IIS 1.0 A (2)
Power Supply Current
LVDS Differential Input High Threshold V
LVDS Differential Input Low Threshold V
White350380mA(3)a
Black
Lcc
TH(LVDS)
TL(LVDS)
490 520 mA (3)b
+100 mV
-100 mV
LVDS Common Mode Voltage VCM 1.125 1.375 V (5)
LVDS Differential Input Voltage |VID| 100 600 mV (5)
Terminating Resistor RT 100 Ohm
Power per EBL WG P
- TBD - W (4)
EBL
Note (1) The ambient temperature is Ta = 25 ± 2 ºC.
Value
Unit Note
V
V
(5),
=1.2V
CM
(5)
=1.2V
CM
Note (2) I
I
: the maximum current when VCC is rising
RUSH
: the maximum current of the first 100ms after power-on
IS
Measurement Conditions: Shown as the following figure. Test pattern: black.
(High to Low)
(Control Signal)
SW
+12V
+3.3V
R1
47K
R2
1K
47K
VR1
C1
1uF
Q1 2SK1475
C2
0.01uF
Q2
2SK1470
FUSE
C3
1uF
Vcc
(LCD Module Input)
7 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 8
Global LCD Panel Exchange Center
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
Vcc rising time is 470us
VCC
0V
I
RUSH
470us
0.1Vcc
0.9Vcc
+3.3V
100ms
I
IS
ICC
Note (3) The specified power supply current is under the conditions at Vcc = 3.3 V, Ta = 25 ± 2 ºC, f
Hz, whereas a power dissipation check pattern below is displayed.
a. White Pattern
b. Black Pattern
= 60
v
Active Area
Active Area
Note (4) The specified power are the sum of LCD panel electronics input power and the converter input
power. Test conditions are as follows.
(a) Vcc = 3.3 V, Ta = 25 ± 2 ºC, f
= 60 Hz,
v
(b) The pattern used is a black and white 32 x 36 checkerboard, slide #100 from the VESA file
CMO doesn’t provide the converter in this product.
8 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 9
Global LCD Panel Exchange Center
|
|
|
|
Note (5) The parameters of LVDS signals are defined as the following figures.
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
Single Ended
Differential
V
V
V
0V
0V
CM
VID
VID
9 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 10
Global LCD Panel Exchange Center
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
3.2 BACKLIGHT UNIT Ta = 25 ± 2 ºC
Parameter Symbol
LED light bar input
voltage
LED light bar input
current
LED Current Peak If - - 100 mADC Per EA
Power Consumption PO 2.35 3.46 4.59 W (2), IL = 120 mA
LED Life Time L
Note (1) LED current is measured by utilizing a high frequency current meter as shown below:
26.1 28.8 30.6 VDC (1), (Duty 100%)
V
O
90 120 150 mADC (1), (Duty 100%)
I
O
12000 - - Hrs (3)
LED
Min. Typ. Max.
Value
Unit Note
9
Note (2) PO = I
Note (3) The lifetime of LED is defined as the time when it continues to operate under the conditions at
OVO
Ta = 25 2
o
C and I = 20 mA(Per EA) until the brightness becomes Љ 50% of its original value.
10 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 11
Global LCD Panel Exchange Center
4. BLOCK DIAGRAM
4.1 TFT LCD MODULE
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
LVDS Display
Data & Clock
Vcc
GND
Data
CLK
EDID
V
EDID
LED Power &
EDID
INPUT CONNECTOR
LED
Converter
LVDS INPUT /
TIMING CONTROLLER
DC/DC CONVERTER &
REFERENCE VOLTAGE
GENERATOR
EDID
EEPROM
SCAN DRIVER IC
TFT LCD PANEL
DATA DRIVER IC
BACKLIGHT UNIT
11 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 12
Global LCD Panel Exchange Center
5. INPUT TERMINAL PIN ASSIGNMENT
5.1 TFT LCD MODULE
Pin Symbol Description Polarity Remark
1 Vss Ground
2 VCC Power Supply +3.3 V (typical)
3 VCC Power Supply +3.3 V (typical)
4 V
5 NC Non-Connection
6 CLK
7 DATA
8 RXO0- LVDS Differential Data Input (Odd) Negative
9 RXO0+ LVDS Differential Data Input (Odd) Positive
10 Vss Ground
11 RXO1- LVDS Differential Data Input (Odd) Negative
12 RXO1+ LVDS Differential Data Input (Odd) Positive
13 Vss Ground
14 RXO2- LVDS Differential Data Input (Odd) Negative
15 RXO2+ LVDS Differential Data Input (Odd) Positive
16 Vss Ground
17 RXOC- LVDS Clock Data Input (Odd) Negative
18 RXOC+ LVDS Clock Data Input (Odd) Positive
19 Vss Ground
20 RXE0- LVDS Differential Data Input (Even) Negative
21 RXE0+ LVDS Differential Data Input (Even) Positive
22 Vss Ground
23 RXE1- LVDS Differential Data Input (Even) Negative
24 RXE1+ LVDS Differential Data Input (Even) Positive
25 Vss Ground
26 RXE2- LVDS Differential Data Input (Even) Negative
27 RXE2+ LVDS Differential Data Input (Even) Positive
28 Vss Ground
29 RXEC- LVDS Clock Data Input (Even) Negative
30 RXEC+ LVDS Clock Data Input (Even) Positive
Note (1) Connector Part No.: JAE-FI-XB30SL-HF10 or equivalent
DDC 3.3V Power
EDID
DDC Clock
EDID
DDC Data
EDID
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
Note (2) User’s connector Part No: FI-X30C2L or equivalent
Note (3) The first pixel is odd as shown in the following figure.
12 / 27
Version 1.0
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Page 13
Global LCD Panel Exchange Center
5.2 BACKLIGHT UNIT
Pin Symbol Description
1 V
L
LED Light-bar Input Power
2 VL LED Light-bar Input Power
3 VL LED Light-bar Input Power
4 NC No connection
5 CH1 Light-bar Feedback Channel 1
6 CH2 Light-bar Feedback Channel 2
7 CH3 Light-bar Feedback Channel 3
Header
Header
Header
Header
Header
Header
Header
Header
EISA ID manufacturer name (“CMO”)
EISA ID manufacturer name (Compressed ASCII)
ID product code (N154Z6-L03) 72
ID product code (hex LSB first; N154Z6-L03) 15
ID S/N (fixed “0”)
ID S/N (fixed “0”)
ID S/N (fixed “0”)
ID S/N (fixed “0”)
Week of manufacture (fixed week code)
Year of manufacture (fixed year code)
EDID structure version # (“1”)
EDID revision # (“3”)
Video I/P definition (“digital”)
Max H image size (“33.12 cm”)
Max V image size (“20.7 cm”)
Display Gamma (Gamma = ”2.2”)
Feature support (“Active off, RGB Color”)
Rx1, Rx0, Ry1, Ry0, Gx1, Gx0, Gy1, Gy0 CC
Bx1, Bx0, By1, By0, Wx1, Wx0, Wy1, Wy0 5D
Rx=0.554 8D
Ry=0.355 5B
Gx=0.351 59
Gy=0.559 8F
Bx=0.161 29
By=0.13 21
Wx=0.312 4F
Wy=0.329 54
Established timings 1
Established timings 2
Manufacturer’s reserved timings
Standard timing ID # 1
Standard timing ID # 1
Standard timing ID # 2
Standard timing ID # 2
Standard timing ID # 3
Standard timing ID # 3
Standard timing ID # 4
Standard timing ID # 4
Standard timing ID # 5
Standard timing ID # 5
Standard timing ID # 6
Standard timing ID # 6
Standard timing ID # 7
Standard timing ID # 7
Standard timing ID # 8
Standard timing ID # 8
VESA CVT Rev1.1)
# 1 Pixel clock (hex LSB first)
# 1 H active (“1680”)
# 1 H blank (“160”)
# 1 H active : H blank (“1680 : 160”)
# 1 V active (”1050”)
# 1 V blank (”30”)
# 1 V active : V blank (”1050 : 30”)
# 1 H sync offset (”48”)
# 1 H sync pulse width ("32”)
# 1 V sync offset : V sync pulse width (”3 : 6”)
(”48: 32 : 3 : 6”)
# 1 H image size (”331.2 mm”) 4B
# 1 V image size (”207.0 mm”) CF
# 1 H image size : V image size (”331.2 : 207”)
# 1 H boarder (”0”)
# 1 V boarder (”0”)
ASCII)
# 2 Flag
# 2 1st character of name (“N”)
# 2 2nd character of name (“1”)
# 2 3rd character of name (“5”)
# 2 4th character of name (“4”)
# 2 5th character of name (“Z”)
# 2 6th character of name (“6”)
# 2 7th character of name (“-”)
# 2 9th character of name (“0”)
# 2 9th character of name (“3”)
# 2 New line character indicates end of ASCII string
# 2 Padding with “Blank” character
# 2 Padding with “Blank” character
Detailed timing description # 3
# 3 Flag
# 3 Reserved
# 3 FE (hex) defines ASCII string (Vendor “CMO”, ASCII)
# 3 Flag
# 3 1st character of string (“C”)
# 3 2nd character of string (“M”)
# 3 3rd character of string (“O”)
# 3 New line character indicates end of ASCII string
# 3 Padding with “Blank” character
# 3 Padding with “Blank” character
# 3 Padding with “Blank” character
# 3 Padding with “Blank” character
# 3 Padding with “Blank” character
# 3 Padding with “Blank” character
# 3 Padding with “Blank” character
# 3 Padding with “Blank” character
# 3 Padding with “Blank” character
Detailed timing description # 4
# 4 Flag
# 4 Reserved
ASCII)
# 4 Flag
# 4 1st character of name (“N”) 4E
# 4 2nd character of name (“1”) 31
# 4 3rd character of name (“5”) 35
# 4 4th character of name (“4”) 34
# 4 5th character of name (“Z”) 5A
# 4 6th character of name (“6”) 36
# 4 7th character of name (“-”) 2D
# 4 8th character of name (“L”) 4C
# 4 9th character of name (“0”)
# 4 9th character of name (“3”)
# 4 New line character indicates end of ASCII string
# 4 Padding with “Blank” character
# 4 Padding with “Blank” character
Extension flag
Checksum
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 18
Global LCD Panel Exchange Center
6. INTERFACE TIMING
6.1 INPUT SIGNAL TIMING SPECIFICATIONS
The input signal timing specifications are shown as the following table and timing diagram.
Signal Item SymbolMin. Typ. Max. Unit Note
DCLK Frequency 1/Tc 53.6 59.6 62.6 MHz (2)
Vertical Total Time TV 105710801090 TH -
Vertical Active Display Period TVD 105010501050 TH -
DE
Note (1) Because of this module is operated by DE only mode, Hsync and Vsync are ignored.
(2) 2 channels LVDS input.
Vertical Active Blanking Period TVB TV-TVD30 TV-TVD TH -
Horizontal Total Time TH 890 920 1010 Tc (2)
Horizontal Active Display Period THD 840 840 840 Tc (2)
Horizontal Active Blanking Period THB
www.panelook.com
TH-THD
80
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
TH-THD
Tc (2)
DE
DCLK
DE
DATA
INPUT SIGNAL TIMING DIAGRAM
TC
HD
T
18 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 19
Global LCD Panel Exchange Center
6.2 POWER ON/OFF SEQUENCE
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
Power Supply
for LCD, Vcc
0V
- LVDS Interface
0V
- Power for Backlight
Timing Specifications:
0.5 Љ t1 Љ 10 ms
0 Љ t2 Љ 50 ms
0 Љ t3 Љ 50 ms
t4 Њ 500 ms
Power On
90%
10%
Power Off
90%
t1
t3t2
Valid Data
t6t5
50%50%
ONOFF OFF
Restart
t7
10%
t4
10%
t5 Њ 200 ms
t6 Њ 200 ms
Note (1) Please follow the power on/off sequence described above. Otherwise, the LCD module might be
damaged.
Note (2) Please avoid floating state of interface signal at invalid period. When the interface signal is invalid, be
sure to pull down the power supply of LCD Vcc to 0 V.
Note (3) The Backlight converter power must be turned on after the power supply for the logic and the
interface signal is valid. The Backlight converter power must be turned off before the power supply
for the logic and the interface signal is invalid.
Note (4) Sometimes some slight noise shows when LCD is turned off (even backlight is already off). To
avoid this phenomenon, we suggest that the Vcc falling time is better to follow (50us)Љt7Љ10 ms.
19 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 20
Global LCD Panel Exchange Center
7. OPTICAL CHARACTERISTICS
7.1 TEST CONDITIONS
Item Symbol Value Unit
Ambient Temperature Ta
Ambient Humidity Ha
Supply Voltage VCC 3.3 V
Input Signal According to typical value in "3. ELECTRICAL CHARACTERISTICS"
LED Light Bar Input Current IL 120 mA
7.2 OPTICAL SPECIFICATIONS
Item Symbol Condition Min. Typ. Max. Unit Note
Contrast Ratio CR500 600 - - (2), (5)
Response Time
Average Luminance of White
Red
Color
Chromaticity
Viewing Angle
White Variation of 5 Points GW
Green
Blue
White
Horizontal
Vertical
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
o
25r2
50r10
TR - 28 ms
- 612 ms
T
F
L
AVE
Rx
Ry
Gx
Gy
Bx
By
=0q, TY =0q
T
x
Viewing Normal Angle
220
TYP.
-0.05
250- cd/m2(4), (5)
0.553
0.358
0.350
0.564
0.160
TYP.
+0.05
0.128
Wx 0.313 Wy
Tx+
T
x
TY+
T
Y
-
-
5p
CRt10
Tx=0q, TY =0q
50 60 -
50 60 -
40 50 -
40 50 -
80 - - % (5),(6)
0.329
C
%RH
-
-
-
-
-
-
-
Deg.(1),(5)
(3)
(1)
20 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 21
Global LCD Panel Exchange Center
.67 ms
Note (1) Definition of Viewing Angle (Tx, Ty):
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
Normal
Tx = Ty = 0º
Ty-Ty
TX- = 90º
6 o’clock
T
y- = 90º
x-
y-
Note (2) Definition of Contrast Ratio (CR):
The contrast ratio can be calculated by the following expression.
Contrast Ratio (CR) = L63 / L0
L63: Luminance of gray level 63
L 0: Luminance of gray level 0
CR = CR (1)
CR (X) is corresponding to the Contrast Ratio of the point X at Figure in Note (6).
Tx
Tx
y+
12 o’clock direction
T
y+ = 90º
x+
TX+ = 90º
Note (3) Definition of Response Time (T
100%
90%
Optical
Response
10%
0%
T
R
66.67 ms
, TF):
R
21 / 27
66
Time
T
F
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 22
Global LCD Panel Exchange Center
(
)
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
Note (4) Definition of Average Luminance of White (L
Measure the luminance of gray level 63 at 5 points
L
= [L (1)+ L (2)+ L (3)+ L (4)+ L (5)] / 5
AVE
L (x) is corresponding to the luminance of the point X at Figure in Note (6)
Note (5) Measurement Setup:
The LCD module should be stabilized at given temperature for 20 minutes to avoid abrupt
temperature change during measuring. In order to stabilize the luminance, the measurement
should be executed after lighting Backlight for 20 minutes in a windless room.
LCD Module
LCD Panel
USB2000
AVE
):
CS-1000T
Center of the Screen
500 mm
Note (6) Definition of White Variation (GW):
Measure the luminance of gray level 63 at 5 points
GW
= Minimum [L (1)+ L (2)+ L (3)+ L (4)+ L (5)] / Maximum [L (1)+ L (2)+ L (3)+ L (4)+ L (5)]
5p
W/4 W
H
H/4
H/2
2 3
Horizontal Line
W
/23W/4
1
Light Shield Room
Ambient Luminance < 2 lux
: Test Point
X
X=1 to 5
Vertical Line
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
3H/4
4
22 / 27
Active Area
5
Version 1.0
www.panelook.com
Page 23
Global LCD Panel Exchange Center
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
8. PRECAUTIONS
8.1 ASSEMBLY AND HANDLING PRECAUTIONS
(1) Do not apply rough force such as bending or twisting to the module during assembly.
(2) To assemble or install module into user’s system can be only in clean working areas. The dust and oil
may cause electrical short or worsen the polarizer.
(3) It’s not permitted to have pressure or impulse on the module because the LCD panel and Backlight will
be damaged.
(4) Always follow the correct power sequence when LCD module is connecting and operating. This can
prevent damage to the CMOS LSI chips during latch-up.
(5) Do not pull the I/F connector in or out while the module is operating.
(6) Do not disassemble the module.
(7) Use a soft dry cloth without chemicals for cleaning, because the surface of polarizer is very soft and
easily scratched.
(8) It is dangerous that moisture come into or contacted the LCD module, because moisture may damage
LCD module when it is operating.
(9) High temperature or humidity may reduce the performance of module. Please store LCD module within
the specified storage conditions.
(10) When ambient temperature is lower than 10ºC may reduce the display quality. For example, the
response time will become slowly, and the starting voltage of CCFL will be higher than room
temperature.
8.2 SAFETY PRECAUTIONS
(1) The startup voltage of Backlight is approximately 1000 Volts. It may cause electrical shock while
assembling with converter. Do not disassemble the module or insert anything into the Backlight unit.
(2) If the liquid crystal material leaks from the panel, it should be kept away from the eyes or mouth. In
case of contact with hands, skin or clothes, it has to be washed away thoroughly with soap.
(3) After the module’s end of life, it is not harmful in case of normal operation and storage.
23 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 24
Global LCD Panel Exchange Center
9. PACKING
9.1 CARTON
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
Figure. 9-1 Packing method
24 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 25
Global LCD Panel Exchange Center
9.2 PALLET
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
Figure. 9-2 Packing method
25 / 27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 26
Global LCD Panel Exchange Center
www.panelook.com
Doc. No.:
Issued Date: Jul. 24, 2008
Model No.: N154Z6 - L03
Preliminary
10. DEFINITION OF LABELS
10.1 CMO MODULE LABEL
The barcode nameplate is pasted on each module as illustration, and its definitions are as following explanation.