One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
A
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
TFT LCD Tentative Specification
MODEL NO.: M190A1-L09
Customer:
pproved by:
Note:
記錄 工作 審核 角色 投票
2006-09-07
11:41:52 CST
2006-08-30
16:57:40 CST
Approve by Dept.
Mgr.(QA RA)
Approve by Director
tomy_chen(陳永一
/52720/54140/43150)
jack_fan(范國書/56810/ 54910)
Assignee Accept
Director Accept
1 / 25
Version 0.0
Page 2
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
- CONTENTS -
REVISION HISTORY
1. GENERAL DESCRIPTION
1.1 OVERVIEW
1.2 FEATURES
1.3 APPLICATION
1.4 GENERAL SPECIFICATIONS
1.5 MECHANICAL SPECIFICATIONS
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATI NGS OF ENVIRONMENT
2.2 ELECTRICAL ABSOLUTE RATINGS
2.2.1 TFT LCD MODULE
2.2.2 BACKLIGHT UNIT
3. ELECTRICAL CHARACTERISTICS
3.1 TFT LCD MODULE
3.2 BACKLIGHT UNIT
4. BLOCK DIAGRAM
4.1 TFT LCD MODULE
4.2 BACKLIGHT UNIT
5. INPUT TERMINAL PIN ASSIGNMENT
5.1 TFT LCD MODULE
5.2 BACKLIGHT UNIT
5.3 COLOR DATA INPUT ASSIGNMENT
6. INTERFACE TIMING
6.1 INPUT SIGNAL TIMING SPECIFICATIONS
6.2 POWER ON/OFF SEQUENCE
7. OPTICAL CHARACTERISTICS
7.1 TEST CONDITIONS
7.2 OPTICAL SPECIFICATIONS
8. PACKAGING
8.1 P A CKING SPECIFICATIONS
8.2 PACKING METHOD
9. DEFINITION OF LABELS
10. PRECAUTIONS
10.1 ASSEMBLY AND HANDLING PRECAUTIONS
10.2 SAFETY PRECAUTIONS
11. MECHANICAL CHARACTERISTICS
2 / 25
Version 0.0
Page 3
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
REVISION HISTORY
Date Section Description
0.0
Aug., 29, 06’
All
M190A1-L09 Specifications was first issued.
3 / 25
Version 0.0
Page 4
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
1. GENERAL DESCRIPTION
1.1 OVERVIEW
M190A1-L09 is a 19” wide TFT Liquid Crystal Display module with 4 CCFL Backlight unit and 30 pins
2ch-LVDS interface. This module supports 1440 x 900 WXGA+ mode and can display 16.7M colors. The
inverter module for Backlight is not built in.
1.2 FEATURES
- Super Wide viewing angle.
- Super High contrast ratio
- Super fast response time
- High color saturation
- WXGA+ (1440 x 900 pixels) resolution
- DE (Data Enable) only mode
- LVDS (Low Voltage Differential Signaling) interface
- RoHS Compliance
1.3 APPLICA TION
- TFT LCD Monitor
1.4 GENERAL SPECIFICATI0NS
Item Specification Unit Note
Diagonal Size 481.4 (19.05” diagonal) mm
Active Area 410.4 (H) x 256.5 (V) mm
Bezel Opening Area 414.36 x 260.45 mm
Driver Element a-si TFT active matrix - Pixel Number 1440 x R.G.B. x 900 pixel Pixel Pitch 0.285 (H) x 0.285 (V) mm Pixel Arrangement RGB vertical stripe - Display Colors 16.7M color Transmissive Mode Normally White - Surface Treat ment Hard coating (3H), Glare - -
(1)
1.5 MECHANICAL SPECIFICATIONS
Item Min. Typ. Max. Unit Note
Horizontal(H) 426.7 427.2 427.7 mm
Module Size
Note (1) Please refer to the attached drawings for more information of front and back outline dimensions.
Vertical(V) 276.9 277.4 277.9 mm
Depth(D) - 16.0 16.5 mm
Weight - - 2200 g -
4 / 25
(1)
Version 0.0
Page 5
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
A
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item Symbol
Storage Temperature TST -20 +60 ºC (1)
Operating Ambient T emperature TOP 0 +50 ºC (1), (2)
Shock (Non-Operating) S
Vibration (Non-Operating) V
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta ≦ 40 ºC).
(b) Wet-bulb temperature should be 39 º C Max. (Ta > 40 ºC).
(c) No condensation.
- 50 G (3), (5)
NOP
- 1.5 G (4), (5)
NOP
Min. Max.
Relative Humidity (%RH)
Value
Unit Note
100
90
80
60
Operating Range
40
20
10
Storage Range
Temperature (ºC)
Note (2) The temperature of panel display surface area should be 0 ºC Min. and 60 ºC Max.
Note (3) 11ms, half sine wave, 1 time for ± X, ± Y, ± Z.
80 60 -20 400 20-40
Note (4) 10 ~ 300 Hz, 10min/cycle, 3 cycles each X, Y, Z.
Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
so that the module would not be twisted or bent by the fixture.
t Room Temperature
Side Mount Fixing Screw
Gap=2mm
Bracket
LCD Module
Side Mount Fixing Screw
Stage
5 / 25
Version 0.0
Page 6
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
2.2 ELECTRICAL ABSOLUTE RATINGS
2.2.1 TFT LCD MODULE
Item Symbol
Power Supply Voltage Vcc -0.3 +6.0 V
Logic Input Voltage VIN -0.3 4.3 V
Min. Max.
2.2.2 BACKLIGHT UNIT
Item Symbol
Lamp Voltage VL - 2.5K V
Lamp Current IL - 7.5 mA
Lamp Frequency FL - 80 KHz
Note (1) Permanent damage to the device may occur if maximum values are exceeded. Function operation
should be restricted to the conditions described under Normal Operating Conditions.
Min. Max.
Value
Value
Unit Note
(1)
Unit Note
(1), (2), IL = 7.0mA
RMS
RMS
(1), (2)
Note (2) Specified values are for lamp (Refer to 3.2 for further information).
6 / 25
Version 0.0
Page 7
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Doc. No.:
Issued Date: Aug., 29, 2006
Model No.: M190A1-L09
Tentative
3. ELECTRICAL CHARACTERISTICS
3.1 TFT LCD MODULE Ta = 25 ± 2 ºC
Parameter Symbol
Min. Typ. Max.
Power Supply Voltage Vcc 4.5 5.0 5.5 V Ripple Voltage VRP - - 100 mV Rush Current I
White 0.5 0.7 A (3)a
Power Supply Current
Black 0.7 1.0 A (3)b
Vertical Stripe
RUSH
-
-
-
- 1.6 3 A (2)
0.7 1.0 A (3)c
LVDS differential input voltage Vid 100 - 600 mV
LVDS common input voltage Vic - 1.2 - V
Logic “L” input voltage Vil Vss - 0.8 V
Note (1) The module should be always operated within above ranges.
Note (2) Measurement Conditions:
Value
Unit Note
+5.0V
R1
47K
Q1 2SK1475
FUSE
C3
1uF
Vcc
(LCD Module Input)
(High to Low)
(Control Signal)
SW
+12V
C1
1uF
VR1
R2
1K
47K
0.01uF
Q2
2SK1470
C2
Vcc rising time is 470µs
+5.0V
0.9Vcc
0.1Vcc
GND
470µs
7 / 25
Version 0.0
Page 8
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
Note (3) The specified power supply current is under the conditions at Vcc = 5.0 V, Ta = 25 ± 2 ºC, fv = 60
Hz, whereas a power dissipation check pattern belo w is displayed.
a. White Pattern
Active Area
c. Vertical Stripe Pattern
b. Black Pattern
Active Area
R
G
R
B
G
R
B
G
RR
G
B
B
B
B
R
R
R
G
G
G
G
B
B
B
B
R
R
Active Area
8 / 25
Version 0.0
Page 9
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Doc. No.:
Issued Date: Aug., 29, 2006
Model No.: M190A1-L09
Tentative
3.2 BACKLIGHT UNIT Ta = 25 ± 2 ºC
Parameter Symbol
Min. Typ. Max.
Lamp Input Voltage VL 697 775 853 V
Lamp Current IL 2.0 7.0 7.5 mA
Lamp Turn On Voltage VS
--- ---
--- --Operating Frequency FL 40 --- 80 KHz (3)
Lamp Life Time LBL 40000 --- --- Hrs (5)
Power Consumption PL --- 21.72 --- W (4), IL = 7.0 mA
Note (1) Lamp current is measured by utilizing high frequency current meters as shown below:
LCD
HV (Pink)
LV (White)
1
2
Value
A
1500(25℃)
1710(0℃)
Inverter
Unit Note
I
RMS
RMS
V
(2)
RMS
(2)
V
RMS
= 7.0 mA
L
(1)
A
Current Meter
YOKOGAWA 2016
HV (Blue)
LV (Black)
1
2
A
Note (2) The voltage shown above should be applied to the lamp for more than 1 second after startup.
Otherwise the lamp may not be turned on.
Note (3) The lamp frequency may produce interference with horizontal synchronous frequency from the
display, and this may cause line flow on the display. In order to avoid interference, the lamp
frequency should be detached from the horizontal synchronous frequency and its harmonics as far
as possible.
Note (4) P
= IL ×VL × 4 CCFLs
L
Note (5) The lifetime of lamp can be defined as the time in which it continues to operate under the condition
Ta = 25 ±2
o
C and IL = 7.0 mA rms until one of the following events occurs:
(a) When the brightness becomes or lower than 50% of its original value.
(b) When the effective ignition length becomes or lower than 80% of its original value. (Effective
ignition length is defined as an area that has less than 70% brightness compared to the
brightness in the center point.)
Note (6) The waveform of the voltage output of inverter must be area-symmetric and the design of the
inverter must have specifications for the modularized lamp. The performance of the Backlight,
such as lifetime or brightness, is greatly influenced by the characteristics of the DC-AC inverter for
the lamp. All the parameters of an inverter should be carefully designed to avoid producing too
much current leakage from high voltage output of the inverter. When designing or ordering the
inverter please make sure that a poor lighting caused by the mismatch of the Backlight and the
inverter (miss-lighting, flicker, etc.) never occurs. If the above situation is confirmed, the module
should be operated in the same manners when it is installed in your instrument.
9 / 25
Version 0.0
Page 10
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
The output of the inverter must have symmetrical (negative and positive) voltage waveform and
symmetrical current waveform.(Unsymmetrical ratio is less than 10%) Please do not use the inverter
which has unsymmetrical voltage and unsymmetrical current and spike wave. Lamp frequency may
produce interface with horizontal synchronous frequency and as a result this may cause beat on the
display. Therefore lamp frequency shall be as away possible from the horizontal synchronous
frequency and from its harmonics in order to prevent interference.
Requirements for a system inverter design, which is intended to have a better display performance, a
better power efficiency and a more reliable lamp. It shall help increase the lamp lifetime and redu ce its
leakage current.
a. The asymmetry rate of the inverter waveform should be 10% below;
b. The distortion rate of the waveform should be within √2 ± 10%;
c. The ideal sine wave form shall be symmetric in positive and negative polarities.
* Asymmetry rate:
I p
I -p
| I
* Distortion rate
I
– I –p | / I
p
(or I –p) / I
p
rms
rms
* 100%
10 / 25
Version 0.0
Page 11
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
9 RXOC+ Positive LVDS differential clock input. (odd)
10 RXO3- Negative LVDS differential data input. Channel O3(odd)
11 RXO3+ Positive LVDS differential data input. Channel O3 (odd)
12 RXE0- Negative LVDS differential data input. Chann el E0 (even)
13 RXE0+ Positive LVDS differential data input. Channel E0 (even)
14 GND Ground
15 RXE1- Negative LVDS differential data input. Chann el E1 (even)
16 RXE1+ Positive LVDS differential data input. Channel E1 (even)
17 GND Ground
18 RXE2- Negative LVDS differential data input. Chann el E2 (even)
19 RXE2+ Positive LVDS differential data input. Channel E2 (even)
20 RXEC- Negative LVDS differential clock input. (even)
21 RXEC+ Positive LVDS differential clock input. (even)
22 RXE3- Negative LVDS differential data input. Chann el E3 (even)
23 RXE3+ Positive LVDS differential data input. Channel E3 (even)
24 GND Ground
25 NC Not connection.
26 NC Not connection.
27 NC Not connection.
28 VCC +5.0V power supply
29 VCC +5.0V power supply
30 VCC +5.0V power supply
Note (1) Connector Part No.: 093G30-B001A (STARCONN ) or FI-X30SSL-HF (JAE) or equi valent.
Note (2) The first pixel is odd.
Note (3) Input signal of even and odd clock should be the same timing.
12 / 25
Version 0.0
Page 13
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
order
LVDS output D26 D25 D24 D22 D21 D20 D19
Data order DE NA NA EB5 EB4 EB3 EB2
LVDS output D23 D17 D16 D11 D10 D5 D27
Data order NA EB7 EB6 EG7 EG6 ER7 ER6
LVDS output D7 D6 D4 D3 D2 D1 D0
Data order OG0 OR5 OR4 OR3 OR2 OR1 OR0
LVDS output D18 D15 D14 D13 D12 D9 D8
Data order OB1 OB0 OG5 OG4 OG3 OG2 OG1
LVDS output D26 D25 D24 D22 D21 D20 D19
Data order DE NA NA OB5 OB4 OB3 OB2
LVDS output D23 D17 D16 D11 D10 D5 D27
Data order NA OB7 OB6 OG7 OG6 OR7 OR6
EB1 EB0 EG5 EG4 EG3 EG2 EG1
13 / 25
Version 0.0
Page 14
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
5.2 BACKLIGHT UNIT
Pin Symbol Description Remark
1 HV High Voltage Pink
2 LV Low Voltage White
1 HV High Voltage Blue
2 LV Low Voltage Black
Note (1) Connector Part No.: BHSR-02VS-1 (JST) or equivalent
Note (2) User’s connector Part No.:SM02B-BHSS-1-TB (JST) or equivalent
5.3 COLOR DATA INPUT ASSIGNMENT
The brightness of each primary color (red, green and blue) is based on the 8-bit gray scale data input for
the color. The higher the binary input, the brighter the color. The table below provides the assignment of
color versus data input.
Data Signal
Basic
Colors
Gray
Scale
Of
Red
Color
Black
Red
Green
Blue
Cyan
Magenta
Yellow
White
Red(0) / Dark
Red(1)
Red(2)
(1) The supply voltage of the external system for the module input should be the same as the definition of Vcc.
(2) Apply the lamp voltage within the LCD operation range. When the backlight turns on before the LCD
operation of the LCD turns off before the backlight turns off, the display may momentarily become abnormal
screen.
(3) In case of VCC = off level, please keep the level of input signals on the low or keep a high impedance.
(4) T4 should be measured after the mo dule has been fully discharged between power of and on period.
(5) Interface signal shall not be kept at high impedance when the power is on.
16 / 25
Version 0.0
Page 17
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Doc. No.:
Issued Date: Aug., 29, 2006
Model No.: M190A1-L09
Tentative
7. OPTICAL CHARACTERISTICS
7.1 TEST CONDITIONS
Item Symbol Value Unit
Ambient Temperature Ta
Ambient Humidity Ha
25±2
50±10
Supply Voltage VCC 5.0 V
Input Signal According to typical value in "3. ELECTRICAL CHARACTERISTICS"
Lamp Current IL 7.0 mA
Inverter Operating Frequency FL 61 KHz
Inverter SUMIDA H05-5307
7.2 OPTICAL SPECIFICATIONS
The relative measurement methods of optical characteristics are shown in 7.2. The following items should
o
C
%RH
be measured under the test conditions described in 7.1 and stable environment shown in Note (5).
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Doc. No.:
Issued Date: Aug., 29, 2006
Model No.: M190A1-L09
Tentative
Note (1) Definition of Viewing Angle (θx, θy):
θX- = 90º
x-
6 o’clock
θ
y- = 90º
y-
Note (2) Definition of Contrast Ratio (CR):
The contrast ratio can be calculated by the following expression.
Normal
θx = θy = 0º
θy-θy+
θx−
θx+
y+
12 o’clock direction
θ
y+ = 90º
x+
θX+ = 90º
Contrast Ratio (CR) = L255 / L0
L255: Luminance of gray level 255
L 0: Luminance of gray level 0
CR = CR (1)
CR (X) is corresponding to the Contrast Ratio of the point X at Figure in Note (6).
Note (3) Definition of Response Time (T
100%
90%
Optical
Response
Gray Level 255
10%
0%
R
T
R
, TF):
Gray Level 0
Gray Level 255
Time
T
F
66.67ms
66.67m
18 / 25
Version 0.0
Page 19
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
X
A
Doc. No.:
Issued Date: Aug., 29, 2006
Model No.: M190A1-L09
Tentative
Note (4) Definition of Luminance of White (LC):
Measure the luminance of gray level 255 at center point
LC = L (1)
L (x) is corresponding to the luminance of the point X at Figure in Note (6).
Note (5) Measurement Setup:
The LCD module should be stabilized at given temperature for 15 minutes to avoid abrupt
temperature change during measuring. In order to stabilize the luminance, the measurement
should be executed after lighting Backlight for 15 minutes in a windless room.
LCD Module
LCD Panel
Center of the Screen
Photometer
(CA-210, CS-1000T)
=
º
Light Shield Room
(Ambient Luminance < 2
Note (6) Definition of White Variation (δW):
Measure the luminance of gray level 255 at 13 points
δW = Maximum [L (1), L (2) ……L (4), L (13)] / Minimum [L (1), L (2) …… L (4), L (13)]
10mm
6
H/4
H
Vertical Line Number
H/4H/4H/4
910
1112
10mm10mm
10mm
Horizontal Line Number
W/4W/4W/4W/4
7
23
1
8
:Test Point X=1 to 13
45
13
W
ctive area
19 / 25
Version 0.0
Page 20
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
8. PACKAGING
8.1 PACKING SPECIFICATIONS
(1) 5 LCD modules / 1 Box
(2) Box dimensions: 545(L) X 320 (W) X 360 (H) mm
(3) Weight: approximately 12.15 Kg (5 modules per box)
8.2 PACKING METHOD
(1) Carton Packing should have no failure in the following reliability test items.
Test Item Test Conditions Note
ISTA STANDARD
Random, Frequency Range: 1 – 200 Hz
Vibration
Dropping Test 1 Angle, 3 Edge, 6 Face, 60cm Non Operation
Top & Bottom: 30 minutes (+Z), 10 min (-Z),
Right & Left: 10 minutes (X)
Back & Forth 10 minutes (Y)
Non Operation
Figure. 8-1 Packing method
20 / 25
Version 0.0
Page 21
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
For ocean shipping
For air transport
Figure. 8-2 Packing method
Figure. 8-3 Packing method
21 / 25
Version 0.0
Page 22
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
9. DEFINITION OF LABELS
9.1 CMO MODULE LABEL
The barcode nameplate is pasted on each module as illustration, and it s definitions are as following explanation.
M190A1-L09 Rev.
XXXXXXXYMDLNNNN
RoHS
CM19A19XXXXXLXXLYM DNNNN
(a) Model Name: M190A1-L09
(b) Revision: Rev. XX, for example: A0, A1… B1, B2… or C1, C2…etc.
(c) CMO barcode definition:
Serial ID: XX
Code Meaning Description
XX CMO internal use XX Revision Cover all the change
X CMO internal use -
YMD
L Product line # Line 1=1, Line 2=2, Line 3=3, …
NNNN Serial number Manufacturing sequence of product
-XX-X-XX-YMD-L-NNNN
Year, month, day Year: 2001=1, 2002=2, 2003=3, 2004=4…
Month: 1~12=1, 2, 3, ~, 9, A, B, C
Day: 1~31=1, 2, 3, ~, 9, A, B, C, ~, W, X, Y, exclude I, O, and U.
(d) Customer’s barcode definition:
Serial ID: CM
Code Meaning Description
CM Supplier code CMO=CM
19A19 Model number M190A1-L09=19A19
X Revision code Non ZBD: 0~9, ZBD: A~Z
X Source driver IC code
X Gate driver IC code
XX Cell location Tainan, Taiwan=TN
L Cell line # 0~12=0~C
XX Module location Tainan, Taiwan=TN
L Module line # 0~12=0~C
YMD
NNNN Serial number Manufacturing sequence of product
Year, month, day Year: 2001=1, 2002=2, 2003=3, 2004=4…
Month: 1~12=1, 2, 3, ~, 9, A, B, C
Day: 1~31= 1, 2, 3, ~, 9, A, B, C, ~, T, U, V
22 / 25
Version 0.0
Page 23
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug., 29, 2006
Doc. No.:
Model No.: M190A1-L09
Tentative
10. PRECAUTIONS
10.1 ASSEMBL Y AND HANDLING PRECAUTIONS
(1) Do not apply rough force such as bending or twisting to the module during assembly.
(2) To assemble or install module into user’s system can be only in clean working areas. The dust and oil
may cause electrical short or worsen the polarizer.
(3) It’s not permitted to have pressure or impulse on the module because the LCD panel and Backlight will
be damaged.
(4) Always follow the correct power sequence when LCD module is connecting and operating. This can
prevent damage to the CMOS LSI chips during latch-up.
(5) Do not pull the I/F connector in or out while the module is operating.
(6) Do not disassemble the module.
(7) Use a soft dry cloth without chemicals for cleaning, because the surface of polarizer is very soft and
easily scratched.
(8) It is dangerous that moisture come into or contacted the LCD module, because moisture may damage
LCD module when it is operating.
(9) High temperature or humidity may reduce the performance of module. Please store LCD module within
the specified storage conditions.
(10) When ambient temperature is lower than 10ºC may reduce the display quality. For example, the
response time will become slowly, and the starting voltage of CCFL will be higher than room
temperature.
10.2 SAFETY PRECAUTIONS
(1) The startup voltage of Backlight is approximately 1000 Volts. It may cause electrical shock while
assembling with inverter. Do not disa ssemble the module or insert anything into the Backlight unit.
(2) If the liquid crystal material leaks from the panel, it should be kept away from the eyes or mouth. In
case of contact with hands, skin or clothes, it has to be washe d away thoroughly with soap.
(3) After the module’s end of life, it is not harmful in case of normal operation and storage.
23 / 25
Version 0.0
Page 24
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Page 25
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.