Item Specifications Unit
Screen Size 14.1 Diagonal inch
Bezel opening area 289.8(W)x218.4(H) mm
Effective display area 285.7(W)x214.3(H) mm
Pixel number 1024 x R.G.Bx768 pixel
Pixel pitch 0.279(H)x0.279(V) mm
Pixel Arrangement R.G.B Vertical Stripe Display Color 6 bits, 262,144 color
Transmissive mode Normally white Surface treatments Hard coating(3H) and anti-glare -
MECHANICAL SPECIFICATIONS
ITEM MIN. TYP. MAX. Unit
Module
size
Gap, panel surface with metal frame- - 0.5 mm
Horizontal 329.5 330 330.5 mm
Vertical 254.5 255 255.5 mm
Depth - 17.0 17.5 mm
Weight - 1250 1300 g
5/22
Version 3.0
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
1. ABSOLUTE MAXIMUM RATINGS
Parameter Symbol
Power supply voltage VCC -0.3 +6.0 V
Logic input voltage VIN -0.3 VCC+0.3 V
Operating temperature Top 0 +50 ºC Module surface*
Storage temperature Tst -20 +60 ºC -
Humidity
Operation 20%~95% relative humidity Ta<=40ºC
Non operation 5%~95% relative humidity Ta<=40ºC
*Measure at the active display area
2. ELECTRICAL SPECIFICATIONS
Parameter Symbol
Power Supply Voltage VCC 4.5 5.0 5.5 V
Power Supply Current l
Ripple voltage VRP - 50 - mV
“H” level logical input voltage VIH 2 - Vcc V
“L” level logical input voltage VIL Vss - 1 V
Parameter Symbol
Lamp Voltage VL 560 630 700 V
Lamp Current IL 1.0 6.0 8.0 mA 2
Startup Voltage VS
Operating Frequency
Power Consumption
Lamp Life time LBL 50000 - - Hrs 6
Pin Symbol Description Remark
1 HV Lamp power input White
2 NC No connect
3 LV Ground Black
Connector Part No.: BHR-03VS-1 (JST)
User’s connector Part No.: SM02 (8.0) B-BHS-1-TB (JST)
www.panelook.com
Values
Min. Max.
MODULE
Valu e
Min. Typ. Max.
140 290 600 mA
CC
BACKLIGHT ( 2 Lamps) Ta=25±2oC
Valu e
Min. Typ. Max.
- - 1255 (25oC)V
- - 1385 (0
F
30 50 70 KHz 4
L
P
6.8 7.6 8.4 W 5, IL=6.0mA
L
The connector information of Black light unit.
o
Doc. No.: 14003173
Issue Date: MAR.16,2000
Model: M141X101
APPROVAL
Unit Remarks
Ta=25ºC
Unit Notes
1
Unit Notes
IL=6.0mA
RMS
3
RMS
C)V
3
RMS
6/22
Version 3.0
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
RGBRG
B
RGB
RGBRG
B
RGB
RGBRG
B
RGB
RGBRG
B
RGB
RGBRG
B
RGB
RGBRG
B
RGB
Note1: Operating Temperature range : 0 ~ 50 ºC.
Power Supply Current specifications are tested by the following test pattern.
(a) Minimal value test pattern : White pattern
(b)Typical value test pattern : 64 gray scale pattern
www.panelook.com
Doc. No.: 14003173
Issue Date: MAR.16,2000
Model: M141X101
APPROVAL
Gray 63
Gray 0
(C) Maximal value test pattern : Vertical 2 pixel white/black pattern
Gray 63
7/22
Version 3.0
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
Note 2: Lamp current is measured by utilizing a current meter for high frequency as shown
below:
Note 3: The voltage shown above should be applied to the lamp for more than 1 second after
startup. Otherwise the lamp may not be turned on. And the start voltage at 0ºC is the
condition that stabilizes in the lamp, and it is the value that guarantees the lighting of
the lamp.
Note 4: The lamp frequency may produce interference with horizontal synchronous frequency
from the display, and this may cause line flow on the display. In order to avoid
interference the lamp frequency should be detached from the horizontal synchronous
frequency and its harmonics as far as possible.
.
Note 5: P
Note 6: The lifetime (Hr) of a lamp can be defined as the time in which it continues to operate
under the condition Ta = 25±2
occurs:
Note 7: The waveform of the voltage output of inverter must be area-symmetric and the
design of the inverter must have specifications for the modularized lamp. The performance of
the backlight, such as lifetime or brightness, is greatly influenced by the characteristics of the
DC-AC inverter for the lamp. All the parameters of an inverter should be designed with care
so as not to produce too much current leakage from high-voltage output of the inverter. When
designing or ordering the inverter, please make sure that a poor lighting caused by the
mismatch of the backlight and the inverter (miss-lighting, flicker, etc.) never occurs. When the
above situation is confirmed, the module should be operated in the same manners as it is
installed in your instrument.
LCD
Module
= IL×VL×2.
L
(1) When the brightness becomes 50% or lower than its original,
(2) When the effective ignition length becomes 80% or lower than its original value.
(Effective ignition length is defined as an area that has less than 70% brightness
compared to the brightness in the center point.)
www.panelook.com
Doc. No.: 14003173
Issue Date: MAR.16,2000
Model: M141X101
APPROVAL
Hot(Whit
GND(Black)
e)
o
C and IL = 6.0 mArms until one of the following event
1
2
Current meter
A
Inverter
8/22
Version 3.0
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.