C&M Britony II T Installation And Servicing Instructions

BRITONY II T
C
*
+
-
Room Sealed Balanced Flue
MULTI POINT WATER HEATER
GGAASS SSAAFFEETTYY ((IINNSSTTAALLLLAATTIIOONN AANNDD UUSSEE)) RREEGGUULLAATTIIOONNSS..
t is the law that all gas appliances are installed by a competant person
I
in accordance with the above regulations.
BRITONY II.T NAT G.C. N° 52 980 04 BRITONY II.T LPG G.C. N° 52 980 09
from serial number 999508276-04
IInnssttaallllaattiioonn
aanndd SSeerrvviicciinngg IInnssttrruuccttiioonnss
(leave these instructions with the user)
The model number and serial number of this heater are on the data badge which is found inside the rear case on the lower left hand side. These numbers should be used when ordering replacement parts.
CCOONNFFOORRMMSS WWIITTHH EEUURROOPPEEAANN SSTTAANNDDAARRDD EENN..2266
c
CCoonntteennttss
15 mm15 mm 15 mm
outlet
inlet
gas
395
300
365
300
15
115
450
95
131
253
655
200
750
90
50
610
PPaaggee 33 :: TTEECCHHNNIICCAALL DDAATTAA
PPaaggeess 44,, 55 aanndd 66 :: IINNSSTTAALLLLAATTIIOONN
PPaaggeess 77,, 88 aanndd 99 :: SSEERRVVIICCIINNGG IINNSSTTRRUUCCTTIIOONNSS
PPaaggeess 1100 aanndd 1111 :: FFAAUULLTT FFIINNDDIINNGG CCHHAARRTT FFOORR BBRRIITTOONNYY IIII TT
PPaaggee 1122 :: SSHHOORRTT LLIISSTT
GGEENNEERRAALL
The BRITONY II T is a cat. II2H 3+ appliance
809124535.02 BRITONY II T NA
809124525.02 BRITONY II T LPG GC N
The BRITONY II T is a balanced flue instantaneous gas fired multipoint water heater. For direct connection to the mains cold water supply.
The BRITONY II T does not require any purpose provides ventilation unless installed in a compartment. A compartment enclos­ing the heater requires high and low level openings communicating with outside air or the room in which the compartment is locat­ed. The free area of these openings must be :
Air from room 252 cm2 (40 in2) 252 cm2 (40 in2)
Air from outside 126 cm
HHiigghh LLeevveell LLooww LLeevveel
2
(20 in2) 126 cm2 (20 in2)
T GC N° 52 980 04
52 980 09
°
l
The installation of the heater must be in accordance with the relevant requirements of the Gas Safety Regulations, Buildings Regulations and the Bye-laws of the local Water Under BRITISH GAS and local authority and the relevant recommendations of the following British Standard Codes of Practice.
BS 5440
BS 5546
BS 6891 Specification for installation of low pressure gas pipework of up to 28 mm
(R1) in domestic pr
Flues and air supply for gas appliances of rated imput not exceeding 60 kW (1st and 2nd family gases) Part 1 - Flues Part 2 - Air Supply
Code of practise for installation of gas hot water supplies for domestic purposes (2nd family gases)
emises (2nd family gas)
taking. It should also be in accordance with any relevant requirements of
2
Technical Data
TABLE 1
Heat imput Nominal ...................................................................................... 23 kW - 78,480 Btu/h
eat output Nominal ..................................................................................... 21 kW - 71,650 Btu/h
H
Gas rate (maximum) :
• Natural gas (G 20) ................................................................................ 2.43 m
• Butan (G 30)......................................................................................... 1.81 kg/h
• Propan (G 31)....................................................................................... 1.79 kg/h
Burner pressure (G 20) .................................................................................. 11.6 mbar - 4.5 in w.g
Main burner injectors marking :
• Natural gas (restrictor ø 5.2) ................................................................. 1.18
• Butan - propan ..................................................................................... 0.70
Pilot injector marking :
• Natural gas ........................................................................................... 0.23
• Butan - propan ..................................................................................... 0.15
Water flow rate - raised 50° C (90° F) ............................................................ 6 l/m - 1.32 g.p.m.
Water flow rate - raised 30° C (54° F) ............................................................ 10.05 l/m - 2.21 g.p.m.
Minimum water pressure............................................................................... 1 Bar - 15 P.S.I.
Maximum water pressure .............................................................................. 10 Bar - 150 P.S.I.
Water inlet - right hand connection................................................................. 15 mm copper
Water outlet - left hand connection................................................................. 15 mm copper
Gas - centre connection ................................................................................. 15 mm copper
3
/h - 88.1 ft3/h
Height............................................................................................................ 655 mm
Width ............................................................................................................. 395 mm
Depth............................................................................................................. 253 mm
Weight............................................................................................................ 19 kg
Space for fixing - Top ..................................................................................... 65 mm
Space for fixing - Bottom ............................................................................... 178 mm
Space for fixing - Sides .................................................................................. 25 mm
Space for fixing - Front .................................................................................. 152 mm
HOLE FOR WALL LINER
Width ............................................................................................................. 305 mm
Height............................................................................................................ 205 mm
ALL THICKNESS
W
Standar
Optional flue set............................................................................................. 75 - 500 mm
The minimum water pressure is for the correct operation of the heater only. An additional allowance must be made for the resisance of the pipework and fittings par ft.) head.
d flue set
............................................................................................ 75 - 355 mm
ticularly wher
e showers and washing machines ar
e used. This should be the equivalent of 2 m (6.5
3
IInnssttaallllaattiioonn
The BRITONY II T is supplied in two cartons, on containing
he heater, the other containing the balanced flue set.
t
IINNSSTTAALLLLIINNGG TTHHEE BBAALLAANNCCEEDD FFLLUUE
The standard flue set is suitable for walls having a thickness of
5 mm (3 in) to 355 mm (14 in). An optional flue set for wall
7 thicknesses up to 500 mm (20 in) is available to special order. Detailed recommandations for flueing are given in BS 5440 :
1. The following notes are for general guidance only. The heater must be installed so that the flue terminal is exposed to the external air. The heater must not be installed so that the terminal discharges into another room or space such as an out­house or lean-to. Termination should be on a clear expanse of wall, the terminal
referably being not less than 300 mm (1 ft.) away from a cor-
p nern recess or projection.
T
DDOO NNOOT
a) within 300 mm (1 ft.) measured vertically from the bottom of
b) within 300 mm (1ft.) above adjacent ground level.
c) within 600 mm (1 ft.) of any surface facing the terminal.
d) immediately beneath eaves or a balcony.
Where the lowest part of the terminal is less than 2 m ( 6,5 ft.) above the level of any ground, balcony, flat roof or place to which any person has access, and which adjoints the wall in which the terminal is situated, the terminal must be protected by a guard of durable material. (A terminal guard is available from
QUINNELL BARRETT & QUINNELL, 071 639 1357.
The air inlet, product outlets duct or terminal of the heater must not be closer than 50 mm (2 in) to any combustible material. Detailed recommandations on the protection of combustible material are given in BS 5440 : 1
PPRREEPPAARRIINNGG TTHHEE WWAALLL
The heater should be installed on a wall of flat non- combustible material that will not reverberate. Whatever the thickness of the wall, make a hole 305 mm (12 in) wide by 205 mm (8 in) high. If the hole is cut accurately there is no need to line it as the wall liner will seal of A minimum clearance of 80 mm (3,2 in) should be left above the top edge of the wall opening. For dimensions and clearance see page 2 and Technical Data, page 3. Slide the wall liner through the wall ensuring that is horizontal and that the flanged end is flush with the face of the inside wall. Trim to length if necessary, so that the outer end of the duct is flush with the face of the outside wall. Make good around the wall liner if necessary (fig. 1). N.B. : For walls of between 75-100 mm (3-4 in), tur liner hooks down through 90°.
install the terminal :
an openable window, air vent or any other ventilation open­ing.
L
f the cavity
E
.
n the wall
FFIITTTTIINNGG TTHHEE FFLLUUEE TTEERRMMIINNAAL
WWaallll LLiinneer
- For walls of 14 ins. (355 mm) or less, use only the flanged wall liner section, measure and cut to length so that the liner extend 1/4 in. from external wall face. Cut “U” cover section to length.
- Assemble by inserting the tabs on the “U” shaped section into t
Turn the tabs over in the direction of the lip on the cover, fit
­hooks with nuts and bolts provided.
- Refit liner into hole and cement into position for a weather proof finish.
- Ensure that the wall liner is horizontal.
- For walls of over 14 in. assemble the telescopic extension piece in the same manner as the flanged section.
- Insert inside the flanged section and extend until it extends 1/4 in. from external wall face, mark around inside of flanged sec­tion.
- Remove liner and extension, cut off surplus from extension leaving a minimum 2 in. overlap making sure extension does not obscure hooks.
- Re-assemble liner and extension, seal around outside of joint with tape supplied.
- Re-fit liner into hole.
- Cement in position for a weather-proof finish.
- Ensure that the liner is horizontal.
NN..BB.. :
hooks but fit the chains into the slots in the bend fixing brack­ets.
FFlluuee DDuucct
For the standard flue set the duct is telescopic and should be ajusted to length to ensure that is fully engages with the termi­nal and the flue bend. The joint should be sealed with the tape supplied.
For walls over 14 in. fit additional telescopic extension piece (total 3 pieces) ensuring a 2 in. overlap. Seal the joint with the
r
he slots on the cover.
:
For walls 3 in. - 4 in. (75 mm - 100 mm) do not use the
t
L
Fig. 1 Fig. 2 Fig. 3
4