Page 2 WP-8: Installation Guide
WP-8
Installation Guide
1 Introduction
The WP-8 remote control plate is a dedicated wall mounting unit
that is compatible with Cloud headphone distribution processors
it has facilities that allow a user to select the music level and
music source whilst monitoring the signal through stereo
headphones and/or low power speakers. The WP-8 is primarily
aimed at scenarios such as tanning suites and treatment rooms
where users may wish to listen to any one of the eight available
programmes. The WP-8 has two low impedance, low power
speaker outputs each with a different operation:
• The first is a normal low impedance speaker output.
• This second provides a similar low impedance output that is
disconnected when headphones are connected to the WP-8.
2 Mechanical installation
The Cloud WP-8 remote control module is designed to be wall mounted. The WP-8 is the same
physical size as a single UK electrical socket (13A Type) and can be mounted in the recessed
back box provided or be surface mounted in a standard 25mm deep housing. (Details of the
WP-8A, a US variant of the WP-8 can be found in section 4).
3 Electrical Installation
The WP-8 should be wired directly to the equipment rack using unscreened
‘Category 5’ cable (4 pair CAT 5), the cable length should not exceed 100m
(328ft). Termination of CAT 5 cable to a WP-8 remote control plate is via an
IDC connector block for which an IDC insertion tool will be required.
The Pump Station 16-R and Sub Station 16-R have an RJ-45 connector for
each remote control unit. The RJ45 plug is a compact 8-pole connector
primarily designed for CAT5 cable. Special tools are available making
termination both easy and quick. The RJ45 plug and socket pin out is shown to
the right:
To terminate an RJ45 plug to CAT5 cable follow the instructions below:
1) Strip approximately 1” of outer sheath from the cable.
2) Remove extraneous material such as plastic wrap or foil screen from the 8 exposed cores
but do not strip their sheaths.
3) Cut the 8 exposed cores down so that when the cable is inserted into the RJ45 the outer
core can be held by the plugs cable retention system.
4) Insert the 8 cores into the RJ45 plug fully making sure that they are all correctly arranged.
(Information on the correct arrangement of cores for the WP-8 can be found in the tables
on page 3&4)
5) Place the plug/cable into the assembly tool and operate the mechanism.
6) You should now have a firmly connected plug/cable assembly that is ready for installation.
Note: These instructions are guidance only; always follow the instructions supplied with the
assembly tool
The WP-8 is fitted with a 3.5mm stereo jack socket that will accept a pair of stereo headphones.
We recommend the use of headphones with an impedance of 32 ohms for example, the Cloud
CP-32.
Please note: The Pump Station 16 and Sub Station 8 have been discontinued as of March
2002 and November 2001 respectively, information regarding wiring an RH-8 to either of these
units can be found on page 4
15-05-02 V4