Cloud CX-A4 Installation & User Manual

CX-A4 Amplifier
Installation & User Guide
V9.0
Cloud Electronics Limited
140 Staniforth Road, Sheffield, S9 3HF England
Fax + 44 (0) 114 242 5462
E-mail
Web site http://www.cloud.co.uk
info@cloud.co.uk
CX-A4 I
NSTALLATION AND OPERATION MANUAL
CX-A4 Amplifier
Installation and operation manual
1

Contents

Section
Page
1 General Description ...................................................................2
2 Installation ..................................................................................2
3 Input Facilities ............................................................................2
4 Output Details ............................................................................4
5 100V Line operation ...................................................................4
6 Configuring the CX-A4 for 100V Line operation ......................... 5
7 Bridged Mode Operation ............................................................ 5
8 Status Indicators ........................................................................5
9 VCA Modules .............................................................................6
10 Peak Limit + VCA Modules ........................................................6
11 Remote Level Connections ........................................................ 6
12 Bose
Equalisation Modules ......................................................7
13 Installing Optional Modules ........................................................ 7
14 Field Servicing............................................................................8
15 General Specifications ...............................................................9
16 Technical Specifications ............................................................. 9
15-07-02 V9
CX-A4 I
NSTALLATION AND OPERATION MANUAL
1 Safety Notes
Do not expose the unit to water or moisture
Do not expose the unit to naked flames.
Do not block or restrict any air vent
Do not operate the unit in ambient temperatures above 35
Do not touch any part or terminal carrying the hazardous live symbol ( )
while power is supplied to the unit.
Do not perform any internal adjustments unless you are qualified to do so and fully understand the hazards associated with mains operated equipment.
The unit has no user serviceable parts. Refer any servicing to qualified service personnel.
If the moulded plug is cut off the lead for any reason, the discarded plug is a potential hazard and should be disposed of in a responsible manner.
For more detailed information refer to the rear of the manual.
2 General
The CX-A4 is a four-channel power amplifier with a maximum channel output of 120 watts into 4 ohms. The unit features extremely low distortion and low noise together with a high slew rate. Full circuit protection is provided and the load is disconnected if the heat sink overheats or any DC is detected at the output. A five-second switch-on delay operates to avoid any switching thumps or other extraneous signals reaching the speaker system. All four input amplifiers are balanced and connect via 3 pin XLR type connectors with adjacent level controls, all mounted on the rear panel. Input signal routing switches are provided and allow the unit to operate in many configurations whilst retaining simple input connections. The CX-A4 amplifier can be used with up to two optional plug-in two channel VCA modules to provide remote level control. Each plug-in module can operate as two individual attenuators or can be linked to operate as a stereo pair with one remote level control.
3 Installation
The CX-A4 is suitable for mounting in a standard 19" equipment rack and occupies two units of rack space. Sufficient ventilation must be provided for the unit. The amplifier draws cool air through the front panel and exhausts through the right side and care must be taken not to obstruct the airflow otherwise the unit may intermittently turn off due to the built-in thermal protection. Applications, which require long, sustained operation at high power levels, should allow a 1U space above and below the unit. The unit is 325mm deep but a depth of 400mm should be allowed to clear the connectors.
4 Input Facilities
All four inputs are balanced and use 3 pin XLR type connectors. All inputs are wired to the standard convention of pin 1 ground, pin 2 in-phase, pin 3 reverse phase, with the shell of the connector connected to the chassis. If the unit is operating in a location which has a high level of electrical or magnetic disturbance or is close to a TV or radio transmitter, we suggest that the input cable screen be connected to the shell of a metal XLR type connector. If the signal is from an unbalanced source, connect pin 3 to pin 1 (ground) inside the XLR type connector and use pin 2 as hot. Every input has a level control adjacent to the respective XLR type connector. Input switching is provided on input channels 2 to 5 allowing a wide variety of input routing configurations. See the schematic diagrams showing details of various routing possibilities. With all input switches depressed, the unit operates as four independent amplifiers. Three stereo pairs, driven from one stereo source and four channels driven from one mono source are also possible together with a combination of the two by suitably configuring the input routing switches.
15-07-02 V9
2
o
C
CX-A4 I
NSTALLATION AND OPERATION MANUAL
POWER
AMPLIFIER
LEVEL
CONTROL
SOURCE
SWITCHES
INPUT
AMPLFIER
POWER
AMPLIFIER
LEVEL
CONTROL
SOURCE
SWITCHES
INPUT
AMPLFIER
3
1 2 3 4
12 13 24
1
INPUT 1
FROM MONO SOURCE
FOUR CHANNELS DRIVEN FROM ONE MONO SOURCE
1 2 3 4
1
INPUT 1
FROM STEREO SOURCE
TWO STEREO PAIRS FROM ONE STEREO SOURCE
2 3 4
12 13 24
2 3 4
INPUT 2
15-07-02 V9