Cloud CAM-16, CAS-16 Installation And User Manual

CAM-16 / CAS-16 User Manual v1.0 1
CAM-16
Audio Distribution Matrix
CAS-16
Audio Distribution Sub-Station
Audio Distribution Matrix
POWER
MUTE
Audio Distribution Sub-Station
CCAASS--1166
POWER
Installation and User Guide
CAM-16 / CAS-16 User Manual v1.02
Important Safety Instructions
WARNING:
To reduce the risk of re or electric shock, do not expose this appliance to rain or moisture.
CAUTION:
Use of controls or adjustments or performance of procedures other than those specied may result in hazardous radiation exposure.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING: SHOCK HAZARD - DO NOT OPEN
AVIS: RISQUE DE CHOC ÉLECTRIQUE - NE PAS OUVRIR
The lightning ash with the arrowhead symbol within an equilateral triangle, is intended to alert you to the presence of
uninsulated dangerous voltages within the product’s enclosure that may be of sufcient magnitude to constitute a risk
of electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Clean only with dry cloth.
6. Do not use this apparatus near water.
7. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including ampliers) that produce heat.
8. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not t into your outlet, consult an electrician for replacement of the obsolete outlet.
9. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
10. Only use attachments/accessories specied by the manufacturer.
11. Use only with the cart, stand, tripod, bracket, or table specied by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
12. Unplug this apparatus during lightning storms or when unused for long periods of time.
13. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. No naked ames, such as lighted candles, should be placed on the apparatus.
WARNING: Excessive sound pressure levels from earphones and headphones can cause hearing loss.
CAM-16 / CAS-16 User Manual v1.0 3
Contents
Important Safety Instructions ..................... 2
Safety Information ........................................ 4
Safety notes regarding installation .......................... 4
Conformities ............................................................... 4
Power supply information ........................................ 4
CAUTION – Servicing ............................................. 4
General Description ...................................... 5
CAM-16 and CAS-16 main features ......................5
Applicable Models: ..................................................... 5
What’s in the Box ...................................................... 5
Block Diagrams ..........................................................6
Front panel descriptions...........................................7
Rear panel descriptions ............................................ 7
Installation ..................................................... 8
Mechanical ................................................................... 8
Connections and adjustments .................................8
Power supply ...........................................................8
Line inputs ................................................................ 8
Global input ............................................................. 8
Outputs 1 to 16 ...................................................... 9
Balanced Line Output
(CAM-16 Output 16 only) ...................................9
Remote Music Mute ...............................................9
The CAS-16 Sub-Station .......................................... 9
Connecting the CAS-16 ...................................... 10
Outputs ...................................................................10
Chassis Ground Terminal .......................................10
Appendix ...................................................... 10
EMC considerations ................................................10
Earthing ......................................................................10
Technical Specications ..........................................11
CAM-16 / CAS-16 User Manual v1.0
4
Safety Information
Safety notes regarding installation
Do not expose this unit to water or moisture
Do not expose the unit to naked ames.
Do not block or restrict any air vent
Do not operate the unit in ambient temperatures above
45°C
The unit has no internal user adjustable parts. Do not
remove any panel.
Refer any servicing to qualied service personnel.
Do not replace the power transformer with any other
type
Conformities
The Cloud CAM-16 and CAS-16 conform to the following European EMC Standards:
BS EN 55103-1:2009
BS EN 55103-2:2009
These products have been tested for normal use in the commercial and light industrial environment. If the equipment is used in controlled EMC environments, the urban outdoors, heavy industrial environments or close to railways, transmitters, overhead power lines etc., the performance of the units may be degraded.
The Cloud CAM-16 and CAS-16 conform to the following European electrical safety standard:
BS EN 60065:2002
The power transformers for the Cloud CAM-16 and CAS-16 conform to the following standards:
Power transformer for the UK market: BS EN60742 + BABT
Power transformer for the European market: EN60742 + EN60950
Power transformer for USA and Canada: C-UL Approved
Power supply information
The CAM-16 and CAS-16 are each shipped with a 15 V AC,
1.25 A transformer. When powering the CAM-16 and CAS­16, please ensure that your local AC supply is within the range of voltages required by the adaptor BEFORE you plug it into the mains. We strongly recommend that you only use the supplied transformer.
When the power switches are in the off (‘O’) position, the CAM-16 and CAS-16 are disconnected from the power transformers.
CAUTION – Servicing
The unit contains no user serviceable parts. Refer servicing to qualied service personnel. Do not perform servicing unless you are qualied to do so. Disconnect the power cable from the unit before removing the top or bottom panel. Only reassemble the unit using bolts/screws identical to the original parts.