ClipperCreek ChargeGuard EX Instructions For Use Manual

ChargeGuardTM EX
Page 1
ChargeGuardTM EX HCS INSTRUCTIONS
ChargeGuardTM EX provides a simple interface to connect the ClipperCreek HCS EVSE to an existing building access control or other third party access control system. With ChargeGuardTM EX a momentary contact closure driven by successful authentication in an access control system can activate the HCS ChargeGuardTM EX enabled station for a single charging session. Alternatively, maintaining the contact closure will leave the station enabled for multiple charging sessions until the connection is released.
When the orange and yellow control wires are shorted together, the EVSE is “ON” and ready to charge a vehicle. When the wires are disconnected, the station is “OFF” and requires a valid activation through the access control system in order to begin charging again.
ChargeGuardTM EX can be utilized in two ways:
1. If individual access control is desired (for each charge session), the access control system will need to provide a momentary short to the orange and yellow wires which will activate the station for a single charge session. In this implementation once the vehicle is disconnected the station will require a successful authorization through the access control system.
2. If open access is desired, connect the orange and yellow wires for as long as open access is desired. As long as the orange and yellow wires are shorted together, the station will be enabled for use.
ChargeGuardTM EX
Page 2
Figure 2. ChargeGuardTM EX: Wiring
Please refer to these instructions to operate the ChargeGuard
TM
EX
enabled HCS EVSE:
1. Connect the HCS EVSE to the vehicle with the SAE-J1772TM
connector.
2. Enable charging by using access control.
3. The “CHARGING” LED light will illuminate green on the
front panel, indicating the vehicle is now being charged.
Figure 1. ChargeGuard
TM
EX
Yellow Wire
Orange Wire
Orange Wire
Yellow Wire
Loading...