Cliplight 580952 User Manual

COMBUSTIBLE GAS LEAK DETECTOR
# 580952
Detects all Hydrocarbon and other Combustible Gases
MSHSA Approved, Intrinsically Safe
User Manual
Introduction
The 580952 features a long life heated sensor technology that is designed to detect all combustible gases including Methane, Propane, butane, Acetylene, Alcohol and Gasoline.
The unique digital leak size indicator of the 580952 takes the guesswork out of whether or not to repair a small leak. The digital display is independent from the audio alarm and sensitivity level, allowing the precise pinpointing of the leak source.
The 580952 does not require rechargeable batteries. An optional detachable LED light will soon be available that clips on to the probe to facilitate leak detection in low light environments.
Features
Unique numeric leak size indicator Methane sensitivity < 10ppm Low battery indicator Audio mute function Intrinsically Safe Certified Bright 3 LED detachable light (optional) 2 year warranty including 2 years on the sensor Long life, stable sensor Automatic calibration & reset to ambient 3 adjustable sensitivity levels Uses 4 AA alkaline batteries Comfortable Sanoprene grip CE certified Made in USA
Gary or Ros OBORNE
Tel: 03 5768 2488 Fax: 03 5768 2688
sales@godistribution.com.au
www.cliplight.com
Leak Size Indicator
The digital leak size indicator remains off normally but once a leak is detected, a number from 1-9 will be displayed for all combustible gases
regardless of the sensitivity setting.
The number will continue to increase or decrease depending on the amount of combustible gas sensed. The maximum value will be displayed once the leak source has been located.
Low Battery Indicator
Replace the 4 AA alkaline batteries when the red LED on the control panel is lit. Follow battery installation Instructions under
Maintenance.
Operating Instructions
1. Turn On: Press the ON/OFF button once to turn on and again to turn off
2. Warm Up: The detector automatically starts heating the sensor. During the heating cycle, the digital leak size indicator will flash 0 and the detector will sound a slow “beep”. Warm up is usually less than 10 seconds.
3. Ready: The detector is ready to begin searching for leaks when the flashing 0 stops and the green sensitivity LED turns on. The audio “beep” increases in frequency and probe LED begins to blink steadily.
Audio Mute Function
To silence or mute the audio beep and alarm signal, press the MUTE button. To restore the audio sound, press the MUTE button again. Note: a few seconds is required to restore the sound if the mute button is pressed in rapid succession.
Adjusting Sensitivity Levels
The Leak Detector will default to the NORM sensitivity level automatically once the unit comes out of the warm up cycle and the green LED will turn on.
To change sensitivity levels, press the SENS once for HI sensitivity (red LED will turn on) and again for LO sensitivity (yellow LED will turn on).
Leak Test Vial
The leak detector comes with a Leak Test Vial that allows the user to ensure the detector is performing properly. To test:
1. Remove the plastic seal cap on the Leak Detector Vial by pulling it off (see Fig. 1)
2. Turn on the detector and allow the unit to complete the warm up cycle.
3. Place the sensor close to the small hole in the top of the Leak Test Vial. The beep rate should increase and the Digital Leak Size Indicator should display a number from 4-6 indicating that the sensor and electronics are working properly.
Fig. 1
NOTE: always remember to replace plastic seal cap after leak test is completed. Replace Test Vial when the green colour is no longer visible.
Maintenance
Batteries:
Install Batteries: Remove screw located at rear end of unit
and pull down hinged battery door to open as shown. Always insert all four batteries into the battery compartment in the same direction. Note polarity mark on the inside of the battery door for proper battery orientation.
Sensor:
Replace Sensor: Remove sensor by unscrewing sensor cover.
Install the new sensor by aligning the notch in sensor socket with the raised tab on sensor socket holder. (see figure below).
Unscrew cover to replace sensor
Push straight on (do not twist) to install sensor
Note:
Do not force sensor into socket. Misalignment can damage the sensor pins.
Ensure sensor is fully inserted for proper operation. The detector will stay in warm-up mode and the on/off switch will become inoperative if the sensor becomes loose or is not fully inserted.
Warranty Policy The 580952 Combustible Gas Leak Detector is warranted to be free of defects in materials & workmanship for two years from the date of purchase. This warranty applies to all repairable instruments that have not been tampered with or damaged through improper use including unauthorised opening of the unit.