IMPORTANT!!!
ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD BE FAMILIAR WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT. ALL INDIVIDUALS WHO USE THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THIS DEVICE.
Inspection:
Ocial periodic inspection must be made at least annually. The inspection must be performed by a qualied person other than the intended user. If severe weather or conditions exist then inspections must be carried out more frequently. All inspection results must be logged in the space provided above.
1. Inspect unit for visible signs of damage or wear that could aect operation. For example: kinked or frayed cables.
2. Make sure all labeling is axed to the unit.
3. Check toggle bar and end termination operate smoothly with no metal burrs.
4. When reusing a previously drilled hole, inspect for for debris or wallowing.
5. Record inspection results in the space provide above.
Part Number Comments
Inspector Name
*If any damage that could aect the strength or operation of the device, or unsafe conditions are found, proper disposal is required. The anchor connector must be rendered unusable and then properly discarded.
V1.2
Toggle Bolt Anchor
5,000-lbs / 22kN
Model: TLA
075N
Assembled in the USA
INSPECTION AND MAINTAINANCE LOG
MODEL NUMBER:
DATE OF MANUFACTURE:
Product Warranty, Limited Remedy and Limitation of Liability
WARRANTY: THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Equipment oered by ClimbTech is
warranted against factory defects in workmanship and materials for a period of one year from date of purchase.
LIMITED REMEDY: Upon notice in writing, ClimbTech will repair or replace all defective items at ClimbTech’s sole discretion. ClimbTech reserves the right to require that the defective item be returned to its plant for inspection before determining the appropriate course action. Warranty does not cover equipment damage resulting from wear, abuse, damage in transit, failure to maintain the product or other damage beyond the control of ClimbTech. ClimbTech shall be the sole judge of product condition and warranty options. This warranty applies only to original purchaser and is the only warranty applicable to this product. Please contact ClimbTech technical service department for assistance.
LIMITATION OF LIABILITY: IN NO EVENT WILL CLIMBTECH BE LIABLE FOR ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED TO LOSS OF PROFITS, IN ANY WAY RELATED TO THE PRODUCTS REGARDLESS OF THE LEGAL THEORY ASSERTED.
Read This Instruction Manual Carefully Before Using This Equipment.
User Instructions must always be available to the user and are not to be removed except by the user of this equipment. For proper use, see supervisor, User Instructions, or contact the manufacturer.
Compliant fall protection and emergency rescue systems help prevent serious injury during fall arrest. Users and purchasers of this equip­ment must read and understand the User Instructions provided for correct use and care of this product. All users of this equipment must understand the instructions, operation, limitations and consequences of improper use of this equipment and be properly trained prior to use per OSHA 29 CFR 1910.66 and 1926.503 or applicable local standards. Misuse or failure to follow warnings and instructions may result
in serious personal injury or death.
Purpose
The
SWY
100
N
is an anchorage connector designed to function as an interface between the anchorage and a fall protection, work positioning, rope access, or rescue system for the purpose of coupling the system to the anchorage. Any references to “anchorage connector” in this manual include, and apply to, the
SWY
100
N
.
Use Instructions
1. Before using a personal fall arrest system, user must be trained in accordance with the requirements of OSHA 29 CFR
1910.66 in the safe use of the system and its components.
2. Use only with ANSI/OSHA compliant personal fall arrest or restraint systems. The anchorage must have the strength capable of supporting a static load, applied in the directions permitted by the system, of at least 10,000-lbf (44kN) in the absence of certication.
3. Use of this product must be approved by an Engineer or other qualied person to be compatible with any and all structural & operational characteristics of the selected installation location and system to be connected to this anchor. Improper use
may result in serious personal injury or death.
4. The anchorage connector must be inspected prior to each use for wear, damage, and other deterioration. If defective components are found the anchor connector must be immediately removed from service, in accordance with the requirments
of OSHA 29 CFR 1910.66 and 1926.502.
5. The complete fall protection system must be planned (including all components, calculating fall clearance, and swing fall) before using.
6. A rescue plan, and the means at hand to implement it, must be in place that provides the prompt rescue of users in the event of a fall, or assures that users are able to rescue themselves.
7. After a fall occurs, anchorage connector must be removed from service and destroyed immediately.
Use Limitations
1. The anchorage connector is designed for up to two users at one time as part of a exible horizontal lifeline system with a capacity up to 310 lbs (140kg) per user including clothing, tools, etc. (See anchorage requirements in the User Instructions for the exible horizontal lifeline system). When used as a direct anchorage connection, the anchorage connector has a single user max capacity of 400 lbs including clothing, tools, etc.
2. The
anchorage connector
may be pulled in any direction shown in the LOADING CONDITIONS DIAGRAM.
3.
The Anchorage connector
is designed to be used in temperatures ranging from -40ºF to +130ºF (-40°C to +54°C).
4. Do not expose the
anchorage connector
to chemicals or harsh solutions which may have a harmful eect.
5. Do not alter or modify this product in anyway.
6. Caution must be taken when using any component of a fall protection, work positioning, rope access, or rescue system near moving machinery, electrical hazards, sharp edges, or abrasive surfaces, as contact may cause equipment failure, personal injury, or death.
7. Do not use/install equipment without proper training by a “competent person” as defined by OSHA 29 CFR 1926.32(f).
8. Do not remove the labeling from this product.
9. Additional requirements and limitations may apply depending on anchorage type and fastening option utilized for installation. All placements must be approved by an engineer or other qualied person. Improper use may result in serious
personal injury or death.
COMPATIBILITY LIMITATIONS
All anchor connectors must only be coupled to compatible connectors. OSHA 29 CFR 1926.502 prohibits snaphooks from being engaged to certain objects unless two requirements are met: it must be a locking type snaphook, and it must be “designed for” making such a connec­tion. “Designed for” means that the manufacturer of the snaphook specifically designed the snaphook to be used to connect to the equip­ment listed. The following connections must be avoided, because they can result in rollout* when a nonlocking snaphook is used:
• Direct connection of a snaphook to horizontal lifeline.
• Two (or more) snaphooks connected to one D-ring.
• Two snaphooks connected to each other.
• A snaphook connected back on its integral lanyard.
• A snaphook connected to a webbing loop or webbing lanyard.
• Improper dimensions of the D-ring, rebar, or other connection point in relation to the snaphook dimensions that would allow the snaphook keeper to be depressed by a turning motion of the snaphook.
*Rollout: A process by which a snaphook or carabiner unintentionally disengages from another connector or object to which it is coupled. (ANSI Z359.1-2007)
MAINTAINANCE, CLEANING AND STORAGE
Cleaning periodically will prolong the life and proper functioning of the product. The frequency of cleaning should be determined by inspec­tion and by severity of the environment. Clean with compressed air and/or a sti brush using plain water or a mild soap and water solution. Do not use any corrosive chemicals that could damage the product. Wipe all surfaces with a clean dry cloth and hang to dry, or use compressed air. When not in use, store anchorage connectors in a cool, dry, clean environment, out of direct sunlight and free of corrosive or other degrading elements.
WARNING
ClimbTech, LLC. / 7303 Burleson Rd. Suite 901 Austin, TX 78744 / 1(888)206-1318 / www.climbtech.com
All products subjected to fall arresting forces should be removed from service immediately!
DECK/FLOOR/GROUND LEVEL
WORK SURFACE
(ANCHOR POINT)
MINIMUM CLEARANCE 3ft (1m)
WARNING!!! SWING FALLS CAN OCCUR WHEN THE WORKIER IS NOT DIRECTLY UNDER ANCHOR POINT.
Free fall distance (limit) must not exceed 6’ ft (1.8 m).
The Hollow Core concrete must be 5000-psi or higher and fully cured. Installation location to be approved by a qualied person.
Performance:
Static tensile strength: 5000-lbf
(22kN) minimum. Maximum capacity: one worker with max weight of 310-lbs when used as a single point anchorage connector for personal fall arrest or restraint
Dimensions:
Weight: 0.4-lbs (.18kg) Length: 11.5” (293mm) Diameter: 0.75” (20mm)
Regulatory compliance
ANSI Z359.1-2007, ANSI Z359.7-2011 and OSHA
1926.502 CE 0321 / EN 795:1996 (+A1:2000) Class B
Component Materials:
Main Cable: Aircraft Cable. Ball Shank: Stainless Steel. Toggle Bar: Stainless Steel. Hole Plug: Aluminum. Spring: Zinc Plated Steel. Swage: Zinc Plated Copper. Activator Wire: Aircraft Cable. Loop Cover: Polyurethane.
WORK SURFACE
May be used as a anchoring point for a leading edge restraint system. (Examples are of optional anchoring point locations. The use of two anchors is for illustration purposes only and not required for leading edge restraint systems unless other­wise specied by the manufacturer.
OPTIONAL
(ANCHOR POINTS)
Toggle Bar
Spring
Swage Anchor Loop
1.5” (38mm)
3.0” (76mm)
10.75” (273mm)
Main Cable
2” (50.8mm)
Activator Wire
Hole Plug
.75”ø (20mm)
Ball Shank
INSTALLATION:
(1) (2) (3)
(4) (5) (6)
Drill 3/4”
(20mm)
Flip
Toggle
To
Verti cal Position
Insert
In
Hole
Push
Down
Pull
Up
INSTALLATION IN HOLLOW CORE CONCRETE:
(1) Drill a 3/4” (20mm) hole in center of the hollow channel in the hollow core concrete. The hollow core concrete must be at least 5,000-psi (34.5 MPa) concrete with a web thickness of 1-3/4” (44.45mm) thick. Works with 6“ hollow core or larger. (2) Never drill any hole closer than 6” (152mm) to any edge or corner. (3) Always inspect the hole carefully when reusing a previously drilled hole. (4) Make sure the toggle bar is fully seated and in lock position. (See activation indicator illistration) (5) The hole plug should be full seated in the drilled hole in the concrete.
INSTALLATION IN STEEL:
(1) Drill a 3/4” (20mm) hole in the steel ange. Steel ange must be at least 1/4” (64mm) thick. (2) Never drill a hole closer than 1-1/2” (38mm) to any edge or corner. (3) When reusing a previously drilled hold always inspect the hole carefully. (4) Make sure the toggle bar is fully seated and in lock position. (See activation indicator illistration)
Location of installation of the toggle anchor must be approved by a
Engineer or other qualied person to be compatible with any and all
structural & operational characteristics of the selected installation location.
WARNING!!!
LOCKED
POSITION
OPEN
POSITION
BLACK RED
BLACK RED
Activator
Wire
Indicator
OPEN
BLACK RED
Activator
Wire
Indicator
NOT
SAFE
Activator
Wire
Indicator
ACTIVATION INDICATOR:
OPEN
OPEN
1-3/4” min web thickness
V1.1
REMOVAL INSTRUCTIONS:
(1) When removing anchor, place your thumb inside the anchor loop
and your rst two ngers around the hole plug. Squeeze ngers and
thumb together till the trigger and spring fully compress.
(2) While squeezing the hole plug and loop pull the anchor out of the
hole.
DO NOT REMOVE WARNING LABEL!
DO
NOT REMOV
E
St
ainle
ss
S
t
e
el, Aluminum
, Zinc
Plate
d Copper, 7
x1
9
A
ir
c
r
a
ft
Ca
bl
e
Compli
a
nc
e:
O
SHA 1926
.50
2 &
19
10
.66 / ANSI Z35
9
.1
CE 032
1 / EN
7
95
:
19
9
6
(+
A
1:
20
0
0
) Cla
s
s B
W
ARNI
N
G!!!
AL
L
P
ER
SO
N
S
U
S
IN
G
TH
I
S E
Q
UIP
M
E
N
T MU
S
T
R
EAD AN
D
UN
D
ER
ST
A
N
D AL
L
I
N
STR
UC
T
I
O
N
S
.
FAILURE
T
O
DO
SO
MAY R
ES
U
LT IN
SE
R
I
O
U
S
I
N
J
U
R
Y
O
R
DEATH
. USER
S
SHO
U
L
D
B
E F
A
M
I
L
I
A
R
W
I
T
H P
ER
TIN
E
N
T R
EG
U
LATIO
N
S GO
V
ER
N
I
N
G
THIS
E
Q
U
I
P
M
E
N
T
. AL
L
IN
DI
V
I
D
U
AL
S
W
HO USE
TH
I
S P
R
O
D
U
CT MU
S
T B
E
P
R
O
P
E
R
LY
IN
S
T
R
U
C
TED O
N
HO
W
TO USE
TH
I
S
D
EV
I
C
E
.
RTL-X
X
X
/ MM/Y
Y
Y
Y
DO NOT REMOVE
Toggle Bolt Anchor
Model: TLA075N
1-(888)-206-1318
Stainless Steel, Aluminum, Zinc Plated Copper, 7x19 Aircraft Cable
Compliance: OSHA 1926.502 & 1910.66 / ANSI Z359.1, ANSI Z359.7
CE 0321 / EN 795:1996 (+A1:2000) Class B
WARNING!!!
ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD BE FAMILIAR WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT. ALL INDIVIDUALS WHO USE THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THIS DEVICE.
RTL-xxx / mm/yyyy
INSPECT BEFORE USE
Max Capacity 310-lbs
Loading...