POVS-1 Series
PIR Occupancy/Vacancy Sensor
Introduction
POVS-1 is a Passive Infrared Motion Sensor that can function as either a security sensor which activates alarm when triggered, or
an occupancy/vacancy sensor which controls home automation or lighting functions via the Control Panel.
Optional models with extra temperature sensor, humidity, and/or ambient light sensor, can provide temperature, humidity/lux
readings and transmit to the Control Panel at regular intervals.
The PIR includes following models, with optional ambient light sensor, temperature sensor, and humidity sensor functions.
Model No. PIR Sensor Light Sensor Temperature Sensor Humidity
POVS-1-LT O O O X
POVS-1-L O O X X
POVS-1-T O X O X
POVS-1RhL O O O O
POVS-1 O X X X
Parts Identification
1. IR Lens w/ LED Indicator
The LED Indicator is located at the center of the IR lens.
In Normal operation mode, the LED Indicator will flash in the following conditions:
- When movement is detected under low battery condition.
- When movement is detected under Test mode.
- When the Test Button is pressed under low battery condition.
2. Battery Compartment
The PIR is powered by one CR123A 3V Lithium battery.
3. Test Button
The test button is used for testing the radio performance and for learning purpose.
4. Magnetic Base
The PIR is deployed on the magnetic base when installing. The magnet within PIR and the base will ensure the PIR
remains attached to the base regardless of PIR location and angle.
Features
Occupancy/Vacancy Detection
When the PIR detects movement, it will transmit a trigger signal. The PIR then begins counting down the occupancy/vacancy
timer. The timer length is adjustable from 30 seconds to 60 minutes via the Control Panel.
During the timer, if the PIR detects movement, the timer will be reset.
When the timer expires without any motion detection, the PIR will transmit a motion detection restore signal and return to
normal operation.
Sensitivity Adjustment
The PIR sensitivity can be adjusted to meet different requirements as either security or occupancy/vacancy sensor. Up to 5
levels of sensitivity may be selected via the Control Panel.
After the PIR is learned into the Control Panel, you can further set its Occupancy/Vacancy Timer & Sensitivity level from the
Control Panel Webpage.
1. Press and hold the Test button on the PIR for three seconds, the LED indicator will light up.
2. Refer to your Control Panel operation manual to edit the device.
3. Go to Occupancy/Vacancy Timer & Sensitivity and select a desired setting from the dropdown menu.
4. Click OK to confirm. The Sensor’s LED will turn bright and then dim to indicate successful operation.
Battery and Low Battery Detection
The PIR uses one CR123A 3V Lithium battery as its power source. The PIR main body must be removed from base to access
1
battery compartment. The battery compartment has a strip which should be pressed under the battery when battery is inserted.
When removing battery, simply lift the strip.
The PIR features Low Battery Detection function. When the battery voltage is low, the PIR will transmit Low Battery signal to
the Control Panel. If movement is detected under Low Battery condition, the LED Indicator will flash to indicate.
If battery is not changed after Low Battery and is exhausted, the LED will flash every 2 seconds and the PIR will stop all
operation.
When changing battery, after removing the old battery, press the Function Button twice to fully discharge before inserting new
battery.
Supervision
The PIR will transmit a supervision signal along with the reading signal to report its condition regularly. The factory default
interval is 30 minutes.
Test Mode
Test mode is for you to check the PIR’s detection range.
To enter Test mode, press the Test button once enter the Test mode for 3 minutes.
During Test Mode, you can trigger PIR sensor to check its detection coverage. If PIR is triggered, the LED will light up to
indicate.
Temperature and Humidity Detection
The sensor measures temperature and humidity to transmit measured data to the Control Panel regularly. The factory
default interval is 30 minutes.
When the temperature changes by +/- 2˚C, the PIR will transmit a signal.
When the humidity changes +/- 10%, the PIR will transmit a signal.
You can also press the Test Button once to transmit a temperature/humidity signal manually.
Light Monitoring
PIR models with built-in ambient light sensor measures illuminance and transmits measured data to the Control Panel
regularly. The factory default interval is 30 minutes.
When the current illuminance changes by +/- 10%, the PIR will also transmit a signal.
You can also press the Test Button once to transmit current lux reading manually.
Getting Started
Pull out the battery insulator to activate battery.
Put the Control Panel into learning mode; refer to Control Panel manual for details.
Press the test button on the PIR.
Refer to Control Panel manual to complete the learn-in process.
After the PIR is learnt-in, put the Control Panel into “Walk Test” mode, hold the PIR in the desired location, and press the
Test button to confirm this location is within signal range of the Control Panel, refer to Control Panel manual to complete
Walk Test.
When you are satisfied that the PIR works in the chosen location, you can proceed to mounting.
Installation
Mounting Height and PIR Detection Coverage
The PIR has detection coverage of a 120∘cone to the front. When mounted at 1.2m to 2.1m height and facing forward, the
PIR has maximum range of 10 meters.
The PIR direction can be changed by simply rotating the PIR on the base. After changing direction, make sure to test the
detection function to confirm the new detection coverage.
Assembly
The PIR is comprised of a front cover and a back cover. The back cover must be separated for battery installation and
learn-in process.
To separate the back cover, hold the PIR in both hands and turn according to picture below to open the PIR.
Installation
The PIR main body has internal magnet at bottom and back, which attaches the main body to PIR magnet base when